Study overviews

Mobile phone related articles are

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on mobile communications

1692 studies in total
  1. 734 studies
  2. 560 studies
  3. 509 studies
  4. 220 studies
  5. 203 studies
  6. 118 studies

Health

734 studies in total
  1. 145 studies
  2. 90 studies
  3. 85 studies
  4. 79 studies
  5. 73 studies
  6. 61 studies
  7. 58 studies
  8. 54 studies
  9. 53 studies
  10. 47 studies
  11. 33 studies
  12. 25 studies
  13. 25 studies
  14. 19 studies
  15. 16 studies
  16. 10 studies
  17. 9 studies
  18. 4 studies

Heart rate/blood pressure 58 studies in total

Authors Year Exposed system Endpoints Frequency range SAR Exposure duration Parameters
Atlasz T et al. 2006 human, partial body heart rate, heart rate variability 900 MHz 1.3 W/kg continuous for 10 min digital mobile phone, GSM, mobile communications
Misek J et al. 2017 human, partial body - 1,788.5 MHz - - mobile communications, RF field, PW pulsed wave
Misek J et al. 2018 human, partial body - 1,788 MHz - - mobile communications, PW pulsed wave
Béres S et al. 2018 human, partial body - 1,800 MHz - - mobile communications, GSM
Umar ZU et al. 2014 human, partial body: chest ECG and blood pressure - - for 15 minutes comprising 3 phases (before calls, during calls and after calls) at 5 minutes each mobile phone, mobile communications
Tamer A et al. 2009 human, partial body: chest (heart reagion) hemodynamic (heart rate, blood pressure) and cardiac electrical activity (P wave and QT interval dispersion) 900–1,800 MHz 2 W/kg - mobile phone, mobile communications
Wilen J et al. 2006 human, partial body: head physiological and cognitive responses 900 MHz 0.8–1 W/kg continuous for 30 min GSM, mobile communications
Parazzini M et al. 2007 human, partial body: head autonomic nervous system response, heart rate variability 900 MHz 0.02 W/kg continuous for 26 min GSM, mobile communications
Andrzejak R et al. 2008 human, partial body: head effect on heart rate variability 1,800 MHz 0.48 W/kg continuous for 20 min mobile phone, digital mobile phone, GSM, mobile communications
Kim DW et al. 2008 human, partial body: head pulse rate, heart rate variability, heart rate, respiratory rate 824.64–848.37 MHz 1.6 W/kg continuous for 31 min mobile communications, mobile phone, CDMA
Nam KC et al. 2009 human, partial body: head pulse rate, heart rate variability, heart rate, respiratory rate, subjective symptoms, perception of radiofrequency exposure 824.64–848.37 MHz 1.22 W/kg continuous for 30 min mobile communications, digital mobile phone, CDMA
Havas M et al. 2010 human, partial body: head heart rate variability 2.4 GHz - continuous for 3 min mobile phone base station, mobile communications, RF field, PW pulsed wave, cordless phone
Kwon MK et al. 2012 human, partial body: head - 1,950 MHz 1.6 W/kg continuous for 32 min digital mobile phone, W-CDMA, mobile communications, microwaves
Parazzini M et al. 2013 human, partial body: head autonomic nervous system response, heart rate variability 900 MHz 0.02 W/g continuous for 26 min mobile phone, GSM, mobile communications
Tahvanainen K et al. 2004 human, partial body: head (ear) heart rate and blood pressure 900 MHz 0.7–1.58 W/kg continuous for 35 min GSM, mobile communications
Nam KC et al. 2006 human, partial body: head (left side) different physiological parameters (blood pressure, heart rate, respiration, skin resistance) 835 MHz 1.6 W/kg continuous for 30 min digital mobile phone, CDMA, mobile communications
Barker AT et al. 2007 human, partial body: head (left side) blood pressure, heart rate variability - 1.3 W/kg continuous for 40 min digital mobile phone, GSM, TETRA/TETRAPOL, mobile communications
Braune S et al. 1998 human, partial body: head (right side) blood pressure, heart rate, capillary perfusion, well-being 900 MHz - continuous for 35 min digital mobile phone, GSM, mobile communications
Mann K et al. 2005 human, partial body: head (vertex) heart rate variability 900 MHz - continuous for 8 h digital mobile phone, GSM, mobile communications
Rezk AY et al. 2008 human, partial body: head of the mother fetal and neonatal heart rate and cardiac output 900 MHz - 10 min mobile phone, GSM, mobile communications
Braune S et al. 2002 human, partial body: head/right blood pressure; heart rate, hormonal parameters (changes in hormone levels) 900 MHz 0.5–0.84 W/kg continuous for 50 min GSM, mobile communications
Mann K et al. 1998 human, partial body: head/vertex heart rate variability 900 MHz - continuous for 8 h digital mobile phone, GSM, mobile communications
Thajudin Ahamed VI et al. 2008 human, partial body: heart, head (ear) heart rate variability, mean heart rate - - - mobile phone, mobile communications, not extractable
Devasia T et al. 2014 human, partial body: left anterior chest wall cardiac parameters (ECG) 900–1,800 MHz - not given mobile phone, GSM, mobile communications
Curcio G et al. 2009 human, partial body: left ear hemodynamics (oxygenation) of the frontal cortex 902.4 MHz 5 W/g 40 min mobile communications, digital mobile phone, GSM