Study overviews

Mobile phone related articles are

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on mobile communications

1692 studies in total
  1. 734 studies
  2. 560 studies
  3. 509 studies
  4. 220 studies
  5. 203 studies
  6. 118 studies

Health

734 studies in total
  1. 145 studies
  2. 90 studies
  3. 85 studies
  4. 79 studies
  5. 73 studies
  6. 61 studies
  7. 58 studies
  8. 54 studies
  9. 53 studies
  10. 47 studies
  11. 33 studies
  12. 25 studies
  13. 25 studies
  14. 19 studies
  15. 16 studies
  16. 10 studies
  17. 9 studies
  18. 4 studies
Authors Year Exposed system Endpoints Frequency range SAR Exposure duration Parameters
Parizek D et al. 2023 human - 2,400–2,600 MHz - - 4G, mobile communications, W-LAN/WiFi
Braune S et al. 2002 human, partial body: head/right blood pressure; heart rate, hormonal parameters (changes in hormone levels) 900 MHz 0.5–0.84 W/kg continuous for 50 min GSM, mobile communications
Tahvanainen K et al. 2004 human, partial body: head (ear) heart rate and blood pressure 900 MHz 0.7–1.58 W/kg continuous for 35 min GSM, mobile communications
Wilen J et al. 2006 human, partial body: head physiological and cognitive responses 900 MHz 0.8–1 W/kg continuous for 30 min GSM, mobile communications
Parazzini M et al. 2007 human, partial body: head autonomic nervous system response, heart rate variability 900 MHz 0.02 W/kg continuous for 26 min GSM, mobile communications
Burgess AP et al. 2016 - - - - - TETRA/TETRAPOL, mobile communications
Nam KC et al. 2006 human, partial body: head (left side) different physiological parameters (blood pressure, heart rate, respiration, skin resistance) 835 MHz 1.6 W/kg continuous for 30 min digital mobile phone, CDMA, mobile communications
Barutcu I et al. 2011 human, partial body: left precordial area cardiac autonomic modulation (heart rate variability) 900–1,800 MHz - three times 5 min (see add. information) digital mobile phone, GSM, TDMA, mobile communications
Barker AT et al. 2007 human, partial body: head (left side) blood pressure, heart rate variability - 1.3 W/kg continuous for 40 min digital mobile phone, GSM, TETRA/TETRAPOL, mobile communications
Braune S et al. 1998 human, partial body: head (right side) blood pressure, heart rate, capillary perfusion, well-being 900 MHz - continuous for 35 min digital mobile phone, GSM, mobile communications
Mann K et al. 1998 human, partial body: head/vertex heart rate variability 900 MHz - continuous for 8 h digital mobile phone, GSM, mobile communications
Mann K et al. 2005 human, partial body: head (vertex) heart rate variability 900 MHz - continuous for 8 h digital mobile phone, GSM, mobile communications
Atlasz T et al. 2006 human, partial body heart rate, heart rate variability 900 MHz 1.3 W/kg continuous for 10 min digital mobile phone, GSM, mobile communications
Yilmaz D et al. 2010 human, partial body: right ear heart rate variability 900 MHz 0.56 W/kg 21 minutes (7 minutes real exposure and 2 x 7 minutes exposure by standy-by mode) digital mobile phone, GSM, mobile communications
Mortazavi SM et al. 2011 human - - - continuous for 10 min digital mobile phone, GSM, mobile communications, microwaves
Kwon MK et al. 2011 human, partial body: left side of the head heart rate, heart rate variability, respiratory rate 1,950 MHz 1.57 W/kg continuous for 32 min digital mobile phone, W-CDMA, mobile communications
Kwon MK et al. 2012 human, partial body: head - 1,950 MHz 1.6 W/kg continuous for 32 min digital mobile phone, W-CDMA, mobile communications, microwaves
Béres S et al. 2018 human, partial body - 1,800 MHz - - mobile communications, GSM
Andrianome S et al. 2017 human - 900 MHz–2.45 GHz - - mobile communications, GSM, W-LAN/WiFi, DECT, RF field, 2.45 GHz
Misek J et al. 2018 human, partial body - 1,788 MHz - - mobile communications, PW pulsed wave
Misek J et al. 2017 human, partial body - 1,788.5 MHz - - mobile communications, RF field, PW pulsed wave
Wallace D et al. 2010 human, whole body electrosensitivity (well-being and different physiological responses) 420 MHz 271 µW/kg continuous for 15 min for the open provocation test, 2 times 5 min for the doble blind test mobile communications, TETRA/TETRAPOL, TDMA, RF field
Nam KC et al. 2009 human, partial body: head pulse rate, heart rate variability, heart rate, respiratory rate, subjective symptoms, perception of radiofrequency exposure 824.64–848.37 MHz 1.22 W/kg continuous for 30 min mobile communications, digital mobile phone, CDMA
Curcio G et al. 2009 human, partial body: left ear hemodynamics (oxygenation) of the frontal cortex 902.4 MHz 5 W/g 40 min mobile communications, digital mobile phone, GSM
Colak C et al. 2012 animal, rat/Wistar, whole body ECG, blood pressure, heart rate 1.9–2.2 GHz - 40 min/day for 20 days mobile communications, digital mobile phone, co-exposure