Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on magnetic power frequency fields (50/60 Hz)

2037 studies in total
  1. 760 studies
  2. 628 studies
  3. 509 studies
  4. 413 studies
  5. 326 studies
  6. 207 studies

Health

760 studies in total
  1. 114 studies
  2. 102 studies
  3. 100 studies
  4. 88 studies
  5. 86 studies
  6. 80 studies
  7. 75 studies
  8. 66 studies
  9. 63 studies
  10. 48 studies
  11. 32 studies
  12. 28 studies
  13. 27 studies
  14. 22 studies
  15. 11 studies
  16. 8 studies
  17. 6 studies
  18. 5 studies
  19. one study
  20. one study

Endocrine changes (melatonin) 75 studies in total

Authors Year Exposed system Parameters Magnetic flux density/field strength
Wood AW et al. 1998 human, whole body magnetic field, 50/60 Hz 20 µT
Burch JB et al. 1999 human, whole body magnetic field, geomagnetic field, 50/60 Hz, occupational, co-exposure 21.7 nT
Akerstedt T et al. 1999 human, whole body magnetic field, 50/60 Hz 1 µT
Burch JB et al. 1999 human, whole body magnetic field, 50/60 Hz, occupational 0.078–0.135 µT
Graham C et al. 2000 human, whole body magnetic field, 50/60 Hz 28.3 µT
Burch JB et al. 2000 human, whole body magnetic field, 50/60 Hz, power transmission line, occupational 0.36–1.05 µT
Hong SC et al. 2001 human, whole body magnetic field, 50/60 Hz, electric blanket 700 nT–8.3 µT
Graham C et al. 2001 human, whole body magnetic field, 50/60 Hz 28.3 µT
Graham C et al. 2001 human, whole body magnetic field, 50/60 Hz 127.3 µT
Davis S et al. 2001 human, whole body magnetic field, 50/60 Hz, residential, co-exposure, also other exposures without EMF 0.1 µT
Graham C et al. 2001 human, whole body magnetic field, 50/60 Hz 28.3 µT
Levallois P et al. 2001 human, whole body electric field, magnetic field, 50/60 Hz, power transmission line, residential 0.13–0.33 µT
Youngstedt SD et al. 2002 human, whole body magnetic field, 50/60 Hz, other domestic appliance, inhouse wiring, residential, co-exposure 100 nT–6.31 µT
Kurokawa Y et al. 2003 human, whole body magnetic field, intermediate frequency, 50/60 Hz 20–100 µT
Touitou Y et al. 2003 human, whole body magnetic field, 50/60 Hz, electrical substation, occupational, residential 0.004–2.6 µT
Ichinose TY et al. 2004 human, whole body magnetic field, 50/60 Hz, occupational 0.04–0.25 µT
Cocco P et al. 2005 human, whole body magnetic field, 50/60 Hz, other domestic appliance, low frequency, residential 0.0045–0.148 µT
Davis S et al. 2006 human, whole body magnetic field, 50/60 Hz 0.5–1 µT
Noonan CW et al. 2002 human, whole body magnetic field, 50/60 Hz, electrical substation, occupational 0.06–0.3 µT
Clark ML et al. 2007 human, whole body Radio/TV transmitter, magnetic field, intermediate frequency, 50/60 Hz, residential 20–130 nT
Bellieni CV et al. 2012 human, whole body magnetic field, 50/60 Hz, therapeutic/medical device 0.45–8.84 µT
Blackman CF et al. 2001 intact cell/cell culture, MCF-7 (human breast cancer cell line) magnetic field, 50/60 Hz 1.2 µT
Rosen LA et al. 1998 intact cell/cell culture, rat pinealcytes magnetic field, static magnetic field, 50/60 Hz, shielding/field deprivation 70 nT–50 µT
Tripp HM et al. 2003 isolated organ, pineal gland magnetic field, 50/60 Hz 500 µT
Lewy H et al. 2003 isolated organ, pineal glands of rats/Wistar magnetic field, 50/60 Hz, co-exposure 1 mT