Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Kim J et al. | 2004 | animal, mouse/ICR, whole body | magnetic field, 50/60 Hz, co-exposure | 0.96–1.98 mT |
Lai H et al. | 1998 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 1 mT |
Sakhnini L et al. | 2012 | animal, mouse, whole body | magnetic field, 50/60 Hz | 1 mT |
Ryu JM et al. | 2009 | invertebrate, common cutworm larvae (<i>Spodoptera litura</i>) | magnetic field, 50/60 Hz | 1 mT |
Salunke BP et al. | 2014 | animal, mouse/Swiss albino, whole body | magnetic field, 50/60 Hz, co-exposure | 1 mT |
Salunke BP et al. | 2014 | animal, mouse/Swiss albino, whole body | magnetic field, 50/60 Hz | 1 mT |
Alsaeed I et al. | 2014 | animal, mouse/BALB/c, whole body | magnetic field, 50/60 Hz | 1 mT |
Bernal-Mondragón C et al. | 2016 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 1 mT |
Jakubowska M et al. | 2019 | invertebrate, common ragworm (<i>Hediste diversicolor</i>), whole body | 50/60 Hz, magnetic field, underground cable | 1 mT |
Ramirez E et al. | 1983 | invertebrate, <i>Drosophila melanogaster</i> (embryo and adults), whole body | magnetic field, static magnetic field, 50/60 Hz | 1–4.5 mT |
Wyszkowska J et al. | 2016 | invertebrate, desert locust (<i>Schistocerca gregaria</i>), whole body | magnetic field, 50/60 Hz, power transmission line | 1–7 mT |
Kitaoka K et al. | 2013 | animal, mouse/ICR, whole body | magnetic field, low frequency, 50/60 Hz | 1.5–3 mT |
Davis HP et al. | 1984 | animal, mouse/CD-1 and mouse/LAF-1, whole body | magnetic field, static magnetic field, 50/60 Hz, DC | 1.65 mT–1.5 T |
Lei Y et al. | 2005 | animal, rat/Sprague-Dawley, whole body | magnetic field, low frequency, 50/60 Hz | 1.8–2.2 mT |
Prolic Z et al. | 2003 | invertebrate, beetle (<i>Morimus funereus</i>) | magnetic field, 50/60 Hz | 2 mT |
Liu T et al. | 2008 | animal, rat/Sprague-Dawley, whole body | magnetic field, low frequency, 50/60 Hz | 2 mT |
He LH et al. | 2011 | animal, rat/Sprague-Dawley, whole body | magnetic field, low frequency, 50/60 Hz | 2 mT |
Park WH et al. | 2012 | animal, mouse/ICR, whole body | magnetic field, 50/60 Hz | 2 mT |
Lovely RH et al. | 1992 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 3.03 mT |
Rostami A et al. | 2016 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 4 mT |
Sienkiewicz ZJ et al. | 1996 | animal, mouse/CD-1, whole body | magnetic field, 50/60 Hz | 5 mT |
Gholami D et al. | 2019 | animal, rat/Wistar, whole body | 50/60 Hz, magnetic field | 5 mT |
Pesic V et al. | 2004 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz, co-exposure | 6 mT |
Jankowska M et al. | 2021 | isolated organ, invertebrate, American cockroach (<i>Periplaneta americana</i>) | 50/60 Hz, magnetic field, also other exposures without EMF | 7 mT |
Korpinar MA et al. | 2012 | animal, rat/Wistar albino, whole body | magnetic field, 50/60 Hz | 10 mT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.