Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on magnetic power frequency fields (50/60 Hz)

2034 studies in total
  1. 758 studies
  2. 628 studies
  3. 509 studies
  4. 412 studies
  5. 326 studies
  6. 208 studies

Health

758 studies in total
  1. 114 studies
  2. 102 studies
  3. 100 studies
  4. 88 studies
  5. 86 studies
  6. 80 studies
  7. 75 studies
  8. 66 studies
  9. 63 studies
  10. 48 studies
  11. 32 studies
  12. 28 studies
  13. 25 studies
  14. 22 studies
  15. 11 studies
  16. 8 studies
  17. 6 studies
  18. 5 studies
  19. one study
  20. one study
Authors Year Exposed system Parameters Magnetic flux density/field strength
Öcal I et al. 2004 animal, rat/Wistar albino, whole body magnetic field, 50/60 Hz 5 mT
Singh M et al. 2004 bidistilled water magnetic field, 50/60 Hz, power transmission line 51.2–362 µT
Quaglino D et al. 2004 animal, rat/Sprague-Dawley, whole body electric field, magnetic field, 50/60 Hz, co-exposure 5–100 µT
Lopucki M et al. 2003 isolated organ, human placentae (after delivery) magnetic field, 50/60 Hz 2 mT
Rajkovic V et al. 2003 animal, rat/Mill Hill, whole body magnetic field, 50/60 Hz 50–500 µT
Attia AA et al. 2002 animal, mouse/Swiss albino, whole body magnetic field, low frequency, 50/60 Hz 100 µT
Tofani S et al. 2002 animal, mouse/CD-1 nu-nu (nude), whole body magnetic field, static magnetic field, 50/60 Hz 1–5.5 mT
Cabrales LB et al. 2001 animal, mouse/Balb/c, whole body magnetic field, 50/60 Hz 110 µT
Rajkovic V et al. 2001 animal, rat/Mill Hill, whole body electric field, magnetic field, 50/60 Hz 50–500 µT
Anderson LE et al. 2001 animal, rat/Fischer 344, whole body magnetic field, 50/60 Hz 1 mT
Matavulj M et al. 2000 animal, rat/Mill Hill, whole body magnetic field, 50/60 Hz 50–500 µT
Kula B et al. 2000 animal, rat/Wistar, whole body magnetic field, static magnetic field, low frequency, 50/60 Hz 0.018–0.49 T
Devevey L et al. 2000 animal, rat/Brown Norway, whole body magnetic field, 50/60 Hz 500 µT
Babbitt JT et al. 2000 animal, mouse/C57BL/6, whole body magnetic field, 50/60 Hz, co-exposure 1.42 mT
Svedenstal BM et al. 1999 animal, mouse/CBA/Ca, whole body magnetic field, 50/60 Hz, power transmission line 8 µT
Kubinyi G et al. 1998 animal, mouse/CFLP (embryos and adults), whole body magnetic field, 50/60 Hz 100 µT
Bellossi A et al. 1998 animal, rat/Wistar, whole body magnetic field, low frequency, signals/pulses, 50/60 Hz 6 mT
Zecca L et al. 1998 animal, rat/Sprague-Dawley, whole body electric field, magnetic field, 50/60 Hz 5–100 µT
Svedenstal BM et al. 1998 animal, mouse/CBA/Ca and CBA/s, whole body magnetic field, low frequency, 50/60 Hz, intermediate frequency 14–15 µT
Harris AW et al. 1998 animal, mouse/Eµ-<i>Pim1</i> transgenic strain and nontransgenic strain C57BL/6NTac, whole body magnetic field, 50/60 Hz 1 µT–1 mT
Ottani V et al. 1997 animal, rat/Wistar albino, whole body signals/pulses, 50/60 Hz, magnetic field 600 µT–8 mT
Romo MA et al. 1997 animal, mouse/OF1, whole body magnetic field, 50/60 Hz 15 µT
Boorman GA et al. 1997 animal, rat/F344/N and mouse/B6C3F1, whole body magnetic field, 50/60 Hz 2–1,000 µT
Hurych J et al. 1996 animal, rat/Wistar magnetic field, low frequency, 50/60 Hz, also other exposures without EMF, co-exposure -
Picazo ML et al. 1996 animal, mouse/OF1, whole body magnetic field, 50/60 Hz 15 µT
Fam WZ et al. 1996 animal, mouse/CFW, whole body magnetic field, 50/60 Hz 25 mT
Margonato V et al. 1995 animal, rat/Sprague-Dawley, whole body magnetic field, 50/60 Hz 5 µT
Del Carratore R et al. 1995 animal, mouse/Swiss albino and rat/Wistar, whole body magnetic field, 50/60 Hz, co-exposure 1.2 mT
Mevissen M et al. 1995 animal, rat/Sprague-Dawley, whole body magnetic field, 50/60 Hz, co-exposure 50 µT
Matsushima S et al. 1993 animal, rat/Wistar-King, whole body magnetic field, 50/60 Hz 5 µT
Duda D et al. 1991 animal, rat/Wistar, whole body magnetic field, static magnetic field, low frequency, 50/60 Hz 20–490 mT
Gimenez-Gonzalez M et al. 1991 animal, rat/Wistar, whole body magnetic field, 50/60 Hz 5.2 mT
Cadossi R 1990 intact cell/cell culture, human peripheral blood lymphocytes (from normal donors, donors with chronic lymphocytic leukemia, and elderly donors), animal, C3H mice, whole body magnetic field, low frequency, signals/pulses, 50/60 Hz, co-exposure -
Gmitrova A et al. 1988 - magnetic field, signals/pulses, 50/60 Hz -
Thomson RA et al. 1988 animal, mouse/DBA/2 (partially implanted with P388 leukemia cells), whole body magnetic field, 50/60 Hz 1.4–500 µT
Malter M et al. 1987 animal, rat and mouse signals/pulses, 50/60 Hz, magnetic field 13.5–26.2 mT
Zecca L et al. 1985 animal, rat/Sprague Dawley (embryo and adult), whole body magnetic field, signals/pulses, 50/60 Hz 5.8 mT
Ottani V et al. 1984 animal, rat/ Wistar albino, whole body magnetic field, low frequency, signals/pulses, 50/60 Hz 600 µT–6 mT