Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on static electric fields

212 studies in total
  1. 121 studies
  2. 93 studies
  3. 23 studies
  4. 19 studies
  5. 13 studies
  6. 12 studies
Authors Year Exposed system Endpoints Parameters Electric field strength
Blondin JP et al. 1996 human, whole body perception of local direct current electric fields static electric field, DC, high-voltage direct current (HVDC) 17.5–50 kV/m
Güler G et al. 1996 animal, guinea pig, whole body - static electric field 0.9–1.9 kV/m
Atalay NS et al. 1995 animal, guinea pig, whole body - static electric field, DC 0.58 kV/m
Atalay NS 1995 animal, guinea pig, whole body - static electric field 1.9 kV/m
Creim JA et al. 1995 animal, rat/Long-Evans - DC, high-voltage direct current (HVDC) 75 kV/m
Oftedal G et al. 1995 human - electric field, magnetic field, static magnetic field, static electric field, low frequency, intermediate frequency, PC/TV monitor, occupational, shielding/field deprivation 0–5 kV/m
Omura Y et al. 1993 human - electric field, static electric field, 50/60 Hz, also other exposures without EMF 20–30 V/m
Creim JA et al. 1993 animal, rat/Long-Evans, whole body - static magnetic field, DC, high-voltage direct current (HVDC) 0–80 kV/m
Gromyko NM et al. 1992 animal, rat/ Wistar, whole body - static electric field, co-exposure 30–160 kV/m
Ganskopp D et al. 1991 animal, cattle, whole body - electric field, high-voltage direct current (HVDC) 0–24.7 kV/m
Kellogg 3rd EW et al. 1986 animal, mouse/NAMRU, whole body - static electric field, DC, high-voltage direct current (HVDC) 1.8–2.4 V/m
Martin FB et al. 1986 animal, cow/Holstein, whole body - static magnetic field, static electric field, DC, power transmission line, high-voltage direct current (HVDC) -
Kato M et al. 1986 animal, cat, partial body: leg - static electric field, DC 240–310 kV/m
Bailey WH et al. 1986 animal, rat/Sprague-Dawley (Holtzman line), whole body - static electric field, DC, co-exposure 30–120 V/cm
Kellogg 3rd EW et al. 1985 animal, mouse/NAMRU, whole body - static electric field, DC, high-voltage direct current (HVDC), co-exposure 1.75–2 kV/m
Kellogg 3rd EW et al. 1985 animal, mouse/NAMRU, whole body - static electric field, DC, high-voltage direct current (HVDC), co-exposure 1.75–2 kV/m
Fam WZ 1981 animal, mouse/ICR-SW - static electric field, DC 340 kV/m
Mitchell JT et al. 1978 animal, mouse/Swiss Ha/ICR, whole body abnormal chromosomes (chromatid exchanges, isochromatid breaks) static electric field 80–160 V/cm
Ng W et al. 1975 animal, rabbit - static electric field, DC -
Krueger AP et al. 1974 animal, mouse/NAMRU - static electric field 1–60 V/cm
Marino AA et al. 1974 animal, rat/Sprague-Dawley and mouse/Swiss Ha/ICR, whole body - static electric field 3–197 V/cm
Marino AA et al. 1974 animal, mouse/Swiss Ha/ICR, whole body - static electric field 27–107 V/cm
Möse JR et al. 1973 animal, mouse/NMRI-Hahn - static electric field 0.04–24 kV/m
Möse JR et al. 1971 animal, mouse/white - static electric field 23.8 kV/m
Krueger AP et al. 1970 animal, mouse/NAMRU - static electric field -
Möse JR et al. 1970 animal, rat and guinea pig, whole body - static electric field 238 V/cm
Möse JR et al. 1970 animal, rat and guinea pig, whole body - static electric field 238 V/cm
Möse JR et al. 1970 animal, mouse - static electric field, DC 238 V/m
Mayyasi AM et al. 1969 animal, rat/King-Holtzmann - static electric field, also other exposures without EMF 1.6–16 kV/m
Altmann G 1969 animal, invertebrate, mouse/white, bird/budgerigar and zebra finch, guinea pig, frog/<i>Rana esculenta</i>, fish/goldfish, locust/<i>Locusta migratoria</i>, whole body - electric field, static electric field, signals/pulses, electric current application 420–2,100 V/m
Altmann G 1968 animal, invertebrate, mouse/white, bird/budgerigar, guinea pig, frog/<i>Rana esculenta</i>, fish/goldfish and guppy and zebrafisch, locust/<i>Locusta migratoria</i>, whole body - static electric field, signals/pulses, touch current 2,000–2,100 V/m
Picton HD 1966 invertebrate, <i>Drosophila melanogaster</i> - static magnetic field, static electric field 3 V/cm
Puharich HK 1966 human, whole body - electric field, static electric field, DC -
Zahner R 1964 animal, Syrian hamster (<i>Mesocricetus auratus</i>), whole body - electric field, static electric field, intermediate frequency, 50/60 Hz, co-exposure 460–2,020 V/m
Barron CI et al. 1964 human, whole body - static electric field, co-exposure 1,000 V/m
Brown Jr FA 1962 invertebrate, planarian/<i>Dugesia dorotocephala</i> - static electric field 2 V/cm
Maw MG 1961 invertebrate, Ichneumonidae (<i>Scambus buolianae</i>), whole body - static electric field, shielding/field deprivation 0.8–1.2 V/cm
Hüsing JO et al. 1960 invertebrate, honeybee (<i>Apis mellifica</i> L.) - electric field, static electric field, 50/60 Hz 50–270 V/cm
Levengood WC et al. 1960 invertebrate, <i>Drosophila melanogaster</i>/wild-type and ehite eye mutant, whole body - static electric field, also other exposures without EMF, co-exposure -
Edwards DK 1960 invertebrate, <i>Drosophila melanogaster</i> and <i>Calliphora vicina</i> - static electric field 10–65.7 kV/m
Krueger AP et al. 1958 animal, rabbit, rat and mouse - static electric field -
Schua L 1954 invertebrate, honeybee - static electric field -
Schua L 1953 animal, Syrian hamster (<i>Mesocricetus auratus</i>), whole body - electric field, static electric field, intermediate frequency 900 V/m