Ferreri F et al. | 2006 | human, partial body: left ear | excitability of each brain hemisphere | 902.4 MHz | 0.5 W/kg | continuous for 45 min | digital mobile phone, GSM, mobile communications |
Freude G et al. | 1998 | human, partial body: left ear | EEG (slow brain potentials) | 916.2 MHz | 0.882–1.42 mW/g | continuous for about 3 or 5 min per task | digital mobile phone, GSM, mobile communications |
Freude G et al. | 2000 | human, partial body: head (left ear) | EEG (slow brain potentials) | 916.2 MHz | 0.882–1.42 mW/g | continuous for about 3 to 4 min per task | GSM, mobile communications |
Garvanova M et al. | 2020 | human | - | - | - | - | mobile communications, mobile phone, GSM |
Gehlen W et al. | 1996 | human, partial body: head | EEG, cognitive functions | 914.2 MHz | - | 10 min | mobile communications, digital mobile phone, PW pulsed wave |
Ghosn R et al. | 2015 | human, partial body: head | alpha waves in the resting EEG | 900 MHz | 0.49–0.93 W/kg | continuous for 26 minutes | mobile phone, GSM, mobile communications |
Gupta N et al. | 2015 | human | acoustic evoked brainstem potentials | - | - | cumulative mobile phone use of <60 minutes/day for 1-5 years | mobile phone, GSM, mobile communications |
Haghani M et al. | 2013 | animal, rat/Wistar, whole body | electrical activity of Purkinje cells, cerebellum-related behaviour | 900 MHz | 0.5–0.9 W/kg | 6 h/day during whole gestation | mobile phone, mobile communications, PW pulsed wave |
Haghani M et al. | 2020 | animal, rat/Wistar | - | 900 MHz | - | - | mobile communications, mobile phone, GSM, RF field, PW pulsed wave |
Hamblin DL et al. | 2004 | human, partial body: head (ear) | event-related potentials and performance during an auditory task | 894.6 MHz | 0.87 W/kg | continuous for 1 h | digital mobile phone, GSM, mobile communications |
Hamblin DL et al. | 2006 | human, partial body: head | neural function/activity | 895 MHz | 0.11 W/kg | continuous for about 21 min | GSM, mobile communications |
Hao D et al. | 2012 | animal, rat/ Wistar, whole body | - | 916 MHz | - | - | mobile communications, mobile phone, RF field |
Henz D et al. | 2018 | human, partial body | - | - | - | - | mobile communications, mobile phone, shielding/field deprivation |
Hidisoglu E et al. | 2016 | animal, rat/Wistar albino, partial body: head | visual evoked potentials and oxidative stress in the brain | 2,100 MHz | 0.57–0.95 W/kg | 2 hours/day for 7 days | GSM, mobile communications, RF field |
Hidisoglu E et al. | 2018 | animal, rat/Wistar albino | - | 2.1 GHz | - | - | GSM, mobile communications, RF field |
Hietanen M et al. | 2000 | human, partial body: head | EEG | 900–1,800 MHz | 850 mW/g | repeated exposure trials for 30 min with 20 min of real exposure | analog mobile phone, digital mobile phone, GSM, NMT, mobile communications |
Hinrichs H et al. | 2004 | human, partial body: head (left ear) | neural activity during retrieval task | 1.87 GHz | 0.61–1.14 W/kg | continuous for 30 min | GSM, mobile communications |
Hinrichs H et al. | 2006 | human, partial body: head, ear | EEG | 1,800 MHz | 0.61–2.28 W/kg | intermittent, 4 min on/3.5 min off, for each condition | digital mobile phone, GSM, mobile communications, CW continuous wave, PW pulsed wave |
Hladký A et al. | 1999 | human, partial body: right ear | EEG | 900 MHz | 0.1 W/kg | continuous for 5 or 6 min | GSM, TDMA, mobile communications |
Hountala CD et al. | 2008 | human, partial body: right ear | brain activity/EEG | 900 MHz | - | 45 min | mobile communications, RF field |
Huber R et al. | 2002 | human, partial body: head | regional cerebral blood flow | 900 MHz | 1 W/kg | continuous for 30 min | GSM, mobile communications, PW pulsed wave |
Jech R et al. | 2001 | human, partial body: right ear | EEG and event-related potentials | 900 MHz | 0.06 W/kg | continuous for 45 min | GSM, mobile communications |
Khullar S et al. | 2013 | human | - | - | - | - | mobile phone, GSM, mobile communications, personal |
Kleinlogel H et al. | 2008 | human, partial body: left ear | effects on event related potentials and cognitive function | 0.9 GHz | 0.1–1 W/kg | continuous for about 30 min | digital mobile phone, GSM, UMTS, CDMA, mobile communications |
Kleinlogel H et al. | 2008 | human, partial body: left ear | EEG, well-being | 0.9 GHz | 0.1–1 W/kg | continuous for about 30 min | digital mobile phone, GSM, UMTS, mobile communications |