Authors Year Exposed system Endpoints Frequency range SAR Exposure duration Parameters
Hinrichs H et al. 2004 human, partial body: head (left ear) neural activity during retrieval task 1.87 GHz 0.61–1.14 W/kg continuous for 30 min GSM, mobile communications
Hinrichs H et al. 2006 human, partial body: head, ear EEG 1,800 MHz 0.61–2.28 W/kg intermittent, 4 min on/3.5 min off, for each condition digital mobile phone, GSM, mobile communications, CW continuous wave, PW pulsed wave
Lustenberger C et al. 2015 human, partial body: left side of the head sleep EEG 900 MHz 0.62–2.12 W/kg continuous for 30 minutes (in each of 2 sessions) mobile phone, mobile communications
Krause CM et al. 2004 human, partial body: head (left ear) EEG during an auditory memory task 902 MHz 0.648–0.878 mW/g continuous for 30 min digital mobile phone, GSM, mobile communications
Roggeveen S et al. 2015 human, partial body: ear or chest event related potentials in the EEG 1.9291–1.9397 GHz 0.69 W/kg - mobile phone, UMTS, mobile communications
Roggeveen S et al. 2015 human, partial body: ear or chest changes in the EEG 1.9291–1.9397 GHz 0.69 W/kg continuous for 15 minutes mobile phone, UMTS, mobile communications
Vorobyov V et al. 2010 animal, rat/Wistar, whole body functioning/activation of different brain areas (EEG) 915 MHz 0.7 mW/g intermittently: 1 min on - 1 min off - for 10 min, 3 times per day for 3 days during a 5 day period (see "additional information") TDMA, mobile communications, low level microwaves, PW pulsed wave
Croft RJ et al. 2010 human, partial body: left/right hemisphere resting EEG (alpha waves) 894.6 MHz 0.7–1.7 W/kg continuous for 55 min GSM, W-CDMA, mobile communications
Leung S et al. 2011 human, partial body: left/right hemisphere event-related potentials and performance during oddball paradigma and n-back task 894.6 MHz 0.7–1.7 W/kg continuous for 55 min GSM, W-CDMA, mobile communications
Trunk A et al. 2014 human, partial body: head - - 0.73–2 W/kg - mobile phone, UMTS, mobile communications, co-exposure