Study overviews

Mobile phone related articles are

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on mobile communications

1699 studies in total
  1. 738 studies
  2. 563 studies
  3. 512 studies
  4. 221 studies
  5. 204 studies
  6. 118 studies

Brain

512 studies in total
  1. 154 studies
  2. 148 studies
  3. 142 studies
  4. 80 studies
  5. 35 studies
  6. 35 studies
  7. 18 studies

Cognitive, psychomotor, or memory functions 142 studies in total

Authors Year Exposed system Endpoints Frequency range SAR Exposure duration Parameters
Son Y et al. 2015 animal, mouse/C57BL/6, whole body cognitive functions and hippocampal histology 1,950 MHz 5 W/kg continuous for 2 hours/day for 60 days mobile phone, W-CDMA, mobile communications
Hao D et al. 2013 animal, rat/Wistar, whole body spatial learning and memory 916 MHz - continuous for 2 x 3 h/day (6 h/day), 5 days/week, 10 weeks mobile phone, mobile communications, RF field
Bamiou DE et al. 2015 human, partial body: ear (each side) perception of verticality and horizontality 882 Hz 0.3–1.3 W/kg continuous for 2 x 30 minutes (30 minutes per ear) mobile phone, GSM, mobile communications, CW continuous wave
Wiholm C et al. 2009 human, partial body: head, ear (left hemisphere) spatial memory and learning 884 MHz 0.23–1.95 W/kg continuous for 2.5 h digital mobile phone, GSM, mobile communications
Sauter C et al. 2015 human, partial body: left side of the head working memory and attention, well-being 385 MHz 1.5–6 W/kg continuous for 2.5 hours TETRA/TETRAPOL, mobile communications
Shirai T et al. 2014 animal, rat/Sprague-Dawley, whole body fertility, development, brain functions and morphology of major organs of rats 2.14 GHz 0.034–0.244 W/g continuous for 20 h/day over 3 generations mobile phone, W-CDMA, mobile communications
Zwamborn APM et al. 2003 human, whole body cognitive performance, well-being 945 MHz 0.000316 µW/kg–0.082 mW/kg continuous for 20 min mobile phone base station, GSM, UMTS, CDMA, TDMA, mobile communications
Lee TM et al. 2003 human, partial body: head attention 1.9 GHz - continuous for 25 min GSM, mobile communications
Preece AW et al. 1999 human, partial body: head/left ear cognitive function 915 MHz - continuous for 25 to 30 min analog mobile phone, digital mobile phone, GSM, mobile communications
Barth A et al. 2012 human, partial body: left or right side of the head cognitive performance 800–1,900 MHz - continuous for 25-1305 min or 3 times 15 min or 28 times 120 min digital mobile phone, GSM, UMTS, mobile communications, PW pulsed wave, theoretical/in silico study