Study overviews

Mobile phone related articles are

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on mobile communications

1694 studies in total
  1. 736 studies
  2. 560 studies
  3. 510 studies
  4. 220 studies
  5. 204 studies
  6. 118 studies

Health

736 studies in total
  1. 146 studies
  2. 90 studies
  3. 85 studies
  4. 80 studies
  5. 73 studies
  6. 61 studies
  7. 58 studies
  8. 54 studies
  9. 53 studies
  10. 47 studies
  11. 33 studies
  12. 25 studies
  13. 25 studies
  14. 19 studies
  15. 16 studies
  16. 10 studies
  17. 9 studies
  18. 4 studies

Hypersensitivity/well-being/subjective complaints 54 studies in total

Authors Year Exposed system Endpoints Frequency range SAR Exposure duration Parameters
Regel SJ et al. 2006 human, whole body well-being, cognitive performance, and perceived field strength 2,140 MHz 6.2 µW/kg–32 mW/kg continuous for 45 min mobile phone base station, UMTS, mobile communications
Eltiti S et al. 2007 human, whole body well-being 886.8–1,879 MHz - continuous for 5, 15, and 50 min mobile phone base station, GSM, UMTS, mobile communications
Rubin GJ et al. 2006 human, partial body: head (left ear) subjective complaints (e.g. headaches, fatigue, nausea, dizziness, sensation of warmth, eye pain) 900 MHz 1.4 W/kg continuous for 50 min GSM, mobile communications, mobile phone
Eltiti S et al. 2009 human, whole body cognitive functioning: short-term memory, attention and perceptual motor speed, working memory, blood volume pulse, heart rate, skin conductance 900–1,800 MHz - continuous for 50 min mobile phone base station, GSM, UMTS, mobile communications
Nieto-Hernandez R et al. 2011 human, partial body: head (left ear) mood and symptoms 385.25 MHz 0.3–1.3 W/kg continuous for 50 min mobile communications, TETRA/TETRAPOL, RF field, CW continuous wave, PW pulsed wave
Kleinlogel H et al. 2008 human, partial body: left ear EEG, well-being 0.9 GHz 0.1–1 W/kg continuous for about 30 min digital mobile phone, GSM, UMTS, mobile communications
Heinrich S et al. 2007 human, whole body well-being 2,167.1 MHz - intermittent, 1, 2, or 3 days on/off (random and double-blind), for a total duration of 3 months (70 working days) mobile phone base station, UMTS, mobile communications
Kwon MS et al. 2008 human, partial body: ear electrosensibility 902 MHz 0.82–1.21 W/kg intermittent, 5 s on or off and a pause for reaction plus 1 s, repeated 100 times digital mobile phone, GSM, mobile communications
Augner C et al. 2009 human, whole body psychological symptoms and health concerns 900 MHz - intermittent, 5 x 50 min, with 5-min breaks mobile phone base station, GSM, mobile communications
van Moorselaar I et al. 2017 human sensing and subjective complaints 50 Hz - maximum of 15 min per condiiton (individually defined during pretests) mobile phone, GSM, UMTS, mobile communications, DECT, cordless phone, W-LAN/WiFi, magnetic field, 50/60 Hz