Authors | Year | Exposed system | Parameters | Electric field strength |
---|---|---|---|---|
Kato M et al. | 1989 | human, partial body: dorsum and palm of the hand | electric field, 50/60 Hz | 10–115 kV/m |
Chapman CE et al. | 2005 | human, partial body: forearm and/or hand | electric field, static electric field, 50/60 Hz, DC, power transmission line, high-voltage direct current (HVDC) | 8–65 kV/m |
Boscolo P et al. | 2001 | human, whole body | electric field, magnetic field, 50/60 Hz | 40–120 V/m |
Mueller CH et al. | 2002 | human, whole body | electric field, magnetic field, 50/60 Hz | 100 V/m |
Jankowiak K et al. | 2021 | human, whole body | static electric field, electric field, 50/60 Hz, power transmission line, high-voltage direct current (HVDC), co-exposure | 4–44 kV/m |
Kursawe M et al. | 2021 | human, whole body | static electric field, electric field, low frequency, 50/60 Hz, power transmission line, high-voltage direct current (HVDC), co-exposure | 2–44 kV/m |
Stevenson AP et al. | 1985 | intact cell/cell culture, CHO (Chinese hamster ovary) cells | electric field, magnetic field, 50/60 Hz | 2.85 V/m |
Caprani A et al. | 2004 | intact cell/cell culture, EA.hy926 cells (human endothelial cell line) | electric field, magnetic field, 50/60 Hz, inhouse wiring, residential | 50 mV/m–5 V/m |
Shckorbatov YG et al. | 2001 | intact cell/cell culture, epithelial cells (from human buccal mucosa) | electric field, 50/60 Hz | 5–110 V/cm |
Phillips JL et al. | 1986 | intact cell/cell culture, human colon carcinoma cell line (Colo 205 and Colo 320 DM) | electric field, magnetic field, 50/60 Hz | - |
Schauerte P et al. | 2011 | intact cell/cell culture, neurons from newborn rats | electric field, signals/pulses, 50/60 Hz, therapeutic/medical device | 2 V/cm |
Morandi MA et al. | 1994 | intact cell/cell culture, peritoneal exudate cells (from Swiss Webster outbred mice) | electric field, magnetic field, 50/60 Hz, co-exposure | 118 V/cm |
Bindokas V et al. | 1984 | invertebrate, honeybee (<i>Apis mellifera</i> L.), whole body | electric field, 50/60 Hz, power transmission line | 7 kV/m |
Bindokas VP et al. | 1989 | invertebrate, honeybee (<i>Apis mellifera</i> L.), whole body | electric field, 50/60 Hz | 100–350 kV/m |
Bindokas VP et al. | 1988 | invertebrate, honeybee (<i>Apis mellifera</i> L.), whole body | electric field, touch current, 50/60 Hz, power transmission line | 10–100 kV/m |
Saikia J et al. | 2019 | isolated bio./chem. substance, beta-amyloid protein | electric field, magnetic field, 50/60 Hz, static electric field | - |
Krug E | 1990 | plant, <i>Picea abies</i> Karst and <i>Pinus sylvestris</i> L. | FM broadcast (UKW), radar, electric field, 50/60 Hz, also other exposures without EMF | 0.2 V/m–10 kV/m |
Odriozola-Serrano I et al. | 2007 | tomato juice | electric field, signals/pulses, 50/60 Hz | 35 kV/cm |