Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Study type | Study group | Observation period | Study location | Endpoints | Parameters |
---|---|---|---|---|---|---|---|
Grell K et al. | 2012 | cohort study | men, women, children, 0–85 years | April 1968 - December 2008 (except 1999) | Denmark | Alzheimer disease, vascular dementia, Parkinson disease, multiple sclerosis, neurological diseases: migraine, epilepsy, vertigo, peripheral nerve diseases | touch current, 50/60 Hz, occupational, personal, electric injuries/electrocution |
Li DK et al. | 2012 | cohort study | children, children in utero, 0–13 years | 1996 - August 2010 | USA | childhood obesity | magnetic field, 50/60 Hz, power transmission line, other domestic appliance, residential, personal |
Nichols L et al. | 2005 | cohort study | men, women | 1973 - 2002 | UK | leukemia and lymphoma, brain tumor, female breast cancer and male breast cancer, oesophagus cancer, stomach cancer, rectum cancer, lung cancer, prostate cancer, bladder cancer and other cancer types, all cancer, neurodegenerative diseases, cardiovascular diseases, suicide and depression, other diseases, mortality | magnetic field, 50/60 Hz, power transmission line, electrical substation, occupational |
Koeman T et al. | 2013 | cohort study | men, women, 55–69 years | 1986, followed-up until 1996 | The Netherlands | total cardiovascular diseases, ischaemic heart disease, acute myocardial infarction, subacute and chronic ischaemic heart diseases, other cardiac diseases, arrhythmias, atherosclerosis and cerebrovascular disease | magnetic field, 50/60 Hz, occupational |
Davanipour Z et al. | 2014 | cohort study | men, women, ≥ 65 years | 1993 - 1994 | USA | severe cognitive dysfunction | magnetic field, 50/60 Hz, occupational |
Sudan M et al. | 2017 | cohort study | women, children, children in utero, 0–7 years | 1996 - 2002 | Denmark | asthma | 50/60 Hz, power transmission line, magnetic field, residential |
Li DK et al. | 2020 | cohort study | men, women, children, children in utero, 0–20 years | 1997 - 2017 | USA | attention-deficit/hyperactivity disorder (ADHD), immun-related comorbidities of asthma or atopic dermatitis | magnetic field, 50/60 Hz, intermediate frequency, power transmission line, other domestic appliance, low frequency, personal, residential |
Sorahan T et al. | 2022 | cohort study | men, women | 1987 - 2018 | UK | motor neuron disease (including amyotrophic lateral sclerosis), all causes | magnetic field, 50/60 Hz, power transmission line, electrical substation, occupational |
Souques M et al. | 2021 | cohort study | men, women | 1995 - 2021 | France | health status (long-term illnesses), neurodegenerative diseases, all cancer, cardiovascular diseases, mortality | magnetic field, 50/60 Hz, low frequency, power transmission line, electrical substation, occupational |
Li DK et al. | 2011 | cohort study, prospective cohort study | children, children in utero, 0–13 years | 1996 - August 2010 | USA | asthma | magnetic field, 50/60 Hz, power transmission line, other domestic appliance, residential, personal |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.