Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on static electric fields

212 studies in total
  1. 121 studies
  2. 93 studies
  3. 23 studies
  4. 19 studies
  5. 13 studies
  6. 12 studies

Other

121 studies in total
  1. 48 studies
  2. 41 studies
  3. 38 studies
  4. 3 studies

Others (general) 38 studies in total

Authors Year Exposed system Endpoints Parameters Electric field strength
Zhang L et al. 2024 <i>Mycosphaerella tassiana</i>, <i>Monilinia laxa</i>, plant, strawberry - magnetic field, static electric field, co-exposure, also other exposures without EMF -
McCormack PD et al. 1985 DNA/RNA DNA strand breaks electric field, signals/pulses, static electric field, also other exposures without EMF, co-exposure 1,200–2,400 V/cm
Carter CS et al. 2020 animal, 3 mouse models for type 2 diabetes - static magnetic field, static electric field, co-exposure -
Angell RF et al. 1990 animal, beef cattle, whole body - static electric field, DC, power transmission line, high-voltage direct current (HVDC) 5.6 kV/m
Kato M et al. 1986 animal, cat, partial body: leg - static electric field, DC 240–310 kV/m
Martin FB et al. 1986 animal, cow/Holstein, whole body - static magnetic field, static electric field, DC, power transmission line, high-voltage direct current (HVDC) -
Kilfoyle AK et al. 2018 animal, fish, whole body cognitive/behavioral endpoints magnetic field, static magnetic field, high-voltage direct current (HVDC), underground cable, 50/60 Hz, DC 0–319 µV/m
Güler G et al. 1996 animal, guinea pig, whole body - static electric field 0.9–1.9 kV/m
Güler G et al. 1996 animal, guinea pig, whole body - static electric field, DC 1.9 kV/m
Atalay NS et al. 1995 animal, guinea pig, whole body - static electric field, DC 0.58 kV/m
Altmann G 1962 animal, invertebrate, honeybee, guinea pig, goldfish, whole body - static electric field, electric current application 420–2,800 V/m
Altmann G 1969 animal, invertebrate, mouse/white, bird/budgerigar and zebra finch, guinea pig, frog/<i>Rana esculenta</i>, fish/goldfish, locust/<i>Locusta migratoria</i>, whole body - electric field, static electric field, signals/pulses, electric current application 420–2,100 V/m
Altmann G 1968 animal, invertebrate, mouse/white, bird/budgerigar, guinea pig, frog/<i>Rana esculenta</i>, fish/goldfish and guppy and zebrafisch, locust/<i>Locusta migratoria</i>, whole body - static electric field, signals/pulses, touch current 2,000–2,100 V/m
Krueger AP et al. 1967 animal, mouse/NAMRU albino - static electric field -
Kellogg 3rd EW et al. 1985 animal, mouse/NAMRU, whole body - static electric field, DC, high-voltage direct current (HVDC), co-exposure 1.75–2 kV/m
Kellogg 3rd EW et al. 1986 animal, mouse/NAMRU, whole body - static electric field, DC, high-voltage direct current (HVDC) 1.8–2.4 V/m
Mitchell JT et al. 1978 animal, mouse/Swiss Ha/ICR, whole body abnormal chromosomes (chromatid exchanges, isochromatid breaks) static electric field 80–160 V/cm
Dowse HB et al. 1969 animal, mouse/white laboratory mouse, whole body - static electric field -
Beardwood CJ et al. 1990 animal, rat/Long-Evans, whole body - static electric field, co-exposure 50 V/cm
Skinner LB et al. 2012 deionized water - DC, static electric field 1,000–1,000,000 kV/m
Odagiri-Shimizu H et al. 1999 human, partial body: arm - static electric field, DC 0–500 kV/m
Shimizu HO et al. 2014 human, partial body: forearm - static electric field, DC -
Chapman CE et al. 2005 human, partial body: forearm and/or hand perception of local direct current and alteranting current electric fields electric field, static electric field, 50/60 Hz, DC, power transmission line, high-voltage direct current (HVDC) 8–65 kV/m
Blondin JP et al. 1996 human, whole body perception of local direct current electric fields static electric field, DC, high-voltage direct current (HVDC) 17.5–50 kV/m
Barron CI et al. 1964 human, whole body - static electric field, co-exposure 1,000 V/m