Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Beason RC et al. | 2002 | animal, zebra finch (<i>Taenopygia guttata</i>), partial body: head | neural activity | 900 MHz | 0.05 W/kg | continuous for 10 min | GSM, mobile communications, microwaves |
Huber R et al. | 2002 | human, partial body: head | regional cerebral blood flow | 900 MHz | 1 W/kg | continuous for 30 min | GSM, mobile communications, PW pulsed wave |
Croft RJ et al. | 2002 | human, partial body: head | neural function/EEG | 900 MHz | - | continuous for 3 x 20 min | GSM, mobile communications |
D'Costa H et al. | 2003 | human, partial body: head | EEG | 900 MHz | - | intermittent for 10 x 5 min, see add. information | GSM, mobile communications |
Erdinc OO et al. | 2003 | animal, mouse, whole body | PTZ-induced seizure activity | 900 MHz | - | continuous for 2 h or 20 h | mobile communications, mobile phone |
Maby E et al. | 2004 | human, partial body: left or right ear | cerebral activity (auditory evoked potentials) | 900 MHz | 1.4 W/kg | - | GSM, mobile communications |
Papageorgiou CC et al. | 2004 | human, partial body: right ear | brain activity/EEG | 900 MHz | - | continuous for about 45 min | mobile communications, mobile phone |
Mausset-Bonnefont AL et al. | 2004 | animal, rat/Wistar, partial body: head | response of the brain | 900 MHz | 6 W/kg | continuous for 15 min | GSM, mobile communications, microwaves |
Oysu C et al. | 2005 | human, partial body: ear | auditory brainstem response | 900 MHz | 0.82 W/kg | continuous for 15 min | digital mobile phone, mobile communications |
Maby E et al. | 2005 | human, partial body: right ear | cerebral activity (auditory evoked potentials) | 900 MHz | 1.4 W/kg | - | GSM, mobile communications |
Papageorgiou CC et al. | 2006 | human, partial body: head (right ear) | brain activity | 900 MHz | - | not specified | mobile communications, mobile phone |
Lopez-Martin E et al. | 2006 | animal, rat/Sprague-Dawley, whole body | seizures, brain activation | 900 MHz | 0.15–1.3 W/kg | continuous for 2 h | GSM, mobile communications |
Esen F et al. | 2006 | human, partial body: ear | neuronal activity of central nervous system | 900 MHz | - | continuous for 5 min | GSM, mobile communications |
Nanou E et al. | 2005 | human, partial body: head | EEG during an auditory memory task | 900 MHz | - | continuous for about 45 min | mobile communications, mobile phone |
Maby E et al. | 2006 | human, partial body: head (right ear) | auditory evoked potentials | 900 MHz | 1.4 W/kg | continuous for a part of the session lasting about 500 s | digital mobile phone, GSM, mobile communications |
Regel SJ et al. | 2007 | human, partial body: head | waking EEG, cognitive performance | 900 MHz | 1 W/kg | continuous for 30 min | digital mobile phone, GSM, mobile communications |
de Seze R et al. | 2001 | human, partial body: head (left or right side) | effects on nervous system, auditory system, and endocrine system | 900 MHz | - | continuous for 1 h | mobile communications, digital mobile phone, GSM, microwaves |
Maby E et al. | 2006 | human | brain activity | 900 MHz | - | continuous for 250 s? | digital mobile phone, GSM, mobile communications |
Perentos N et al. | 2007 | human, partial body: left hemisphere | EEG pattern | 900 MHz | 1.56 W/kg | intermittent, 3 x 15 min, see add. information | digital mobile phone, GSM, mobile communications |
Kleinlogel H et al. | 2008 | human, partial body: left ear | effects on event related potentials and cognitive function | 0.9 GHz | 0.1–1 W/kg | continuous for about 30 min | digital mobile phone, GSM, UMTS, CDMA, mobile communications |
Kleinlogel H et al. | 2008 | human, partial body: left ear | EEG, well-being | 0.9 GHz | 0.1–1 W/kg | continuous for about 30 min | digital mobile phone, GSM, UMTS, mobile communications |
Hountala CD et al. | 2008 | human, partial body: right ear | brain activity/EEG | 900 MHz | - | 45 min | mobile communications, RF field |
Lopez-Martin E et al. | 2009 | animal, rat/Sprague-Dawley, whole body | c-Fos expression in the brain, EEG, clinical signs of seizure or jerks | 900 MHz | 0.05–1.4 W/kg | continuous for 2 hr | mobile communications, mobile phone, digital mobile phone, GSM, PW pulsed wave |
de Tommaso M et al. | 2009 | human, partial body: head (left side) | contingent negative variation | 900 MHz | 0.5 W/kg | 48 trials with intervals of 4 s to 6 s | mobile phone, digital mobile phone, GSM, mobile communications |
Maganioti AE et al. | 2010 | human, partial body: right ear | EEG: changes in event-related potentials during a memory task (P600 wave form) | 900 MHz | - | about 45 min. | mobile phone, mobile communications, RF field |
Loughran SP et al. | 2013 | human, partial body: head | waking EEG, cognitive performance | 900 MHz | 0.35–1.4 W/kg | continuous for 30 min | mobile phone, GSM, mobile communications, PW pulsed wave |
Lustenberger C et al. | 2013 | human, partial body: head | brain activity during sleep | 900 MHz | 0.125–10 W/kg | intermittent during 8 h (during the sleep; exposure of 5 min "Intermittent-1" was followed by 1 min with no exposure (OFF phase), then 5 min "Intermittent-2" was followed by a 7 min OFF phase; this 18 min sequence was repeated throughout the whole night | mobile phone, mobile communications, RF field |
Relova JL et al. | 2010 | human | - | 900 MHz | - | - | mobile phone, GSM, mobile communications |
Haghani M et al. | 2013 | animal, rat/Wistar, whole body | electrical activity of Purkinje cells, cerebellum-related behaviour | 900 MHz | 0.5–0.9 W/kg | 6 h/day during whole gestation | mobile phone, mobile communications, PW pulsed wave |
Razavinasab M et al. | 2016 | animal, rat/Wistar, whole body | electrophysiological changes of pyramidal cells, learning and memory | 900 MHz | 0.3–0.9 W/kg | 6 h/day during gestation | mobile phone, mobile communications |
Lustenberger C et al. | 2015 | human, partial body: left side of the head | sleep EEG | 900 MHz | 0.62–2.12 W/kg | continuous for 30 minutes (in each of 2 sessions) | mobile phone, mobile communications |
Ghosn R et al. | 2015 | human, partial body: head | alpha waves in the resting EEG | 900 MHz | 0.49–0.93 W/kg | continuous for 26 minutes | mobile phone, GSM, mobile communications |
Altun G et al. | 2017 | animal, rat/ Wistar albino, partial body | - | 900 MHz | - | - | mobile communications, mobile phone, co-exposure |
Tafakori S et al. | 2020 | animal, rat/ Wistar | - | 900 MHz | - | - | mobile communications, mobile phone |
Haghani M et al. | 2020 | animal, rat/Wistar | - | 900 MHz | - | - | mobile communications, mobile phone, GSM, RF field, PW pulsed wave |
Er H et al. | 2020 | animal, rat/ Wistar albino | - | 900 MHz | - | - | mobile phone, mobile communications, GSM, RF field |
Wallace J et al. | 2022 | human, partial body | - | 900 MHz | - | - | mobile communications, mobile phone, GSM |
Wallace J et al. | 2021 | human, partial body | - | 900 MHz | - | - | mobile communications, mobile phone, RF field |
Azmy R et al. | 2020 | human | - | 900 MHz | - | - | mobile communications, mobile phone, GSM |
Yavaş MC | 2020 | human, partial body | - | 900 MHz | - | - | mobile communications, mobile phone |
Wallace J et al. | 2023 | human | - | 900 MHz | - | - | mobile communications, mobile phone, GSM |
van der Meer JN et al. | 2023 | human | - | 900 MHz | - | - | mobile communications, mobile phone, GSM |
Kouchaki E et al. | 2016 | animal, mouse/BALB/c, whole body | risk for epileptic seizures | 900–950 MHz | - | continuous for 30 minutes | mobile phone, GSM, mobile communications, co-exposure |
Hietanen M et al. | 2000 | human, partial body: head | EEG | 900–1,800 MHz | 850 mW/g | repeated exposure trials for 30 min with 20 min of real exposure | analog mobile phone, digital mobile phone, GSM, NMT, mobile communications |
El-Komey F | 2005 | human, partial body | - | 900–1,800 MHz | - | - | mobile phone, mobile communications, GSM |
Krause CM et al. | 2000 | human, partial body: head (right ear) | EEG (during a memory task) | 902 MHz | - | continuous for 30 min | GSM, mobile communications |
Krause CM et al. | 2000 | human, partial body: head (rigth side) | EEG (during a visual working memory task) | 902 MHz | - | continuous for about 30 min | GSM, mobile communications |
Krause CM et al. | 2004 | human, partial body: head (left ear) | EEG during an auditory memory task | 902 MHz | 0.648–0.878 mW/g | continuous for 30 min | digital mobile phone, GSM, mobile communications |
Krause CM et al. | 2006 | human, partial body: head | oscillatory EEG responses during cognitive processing in children | 902 MHz | 1.4–1.98 W/kg | continuous for 30 min | GSM, mobile communications |
Krause CM et al. | 2007 | human, partial body: head (rigth and left side) | EEG (during a visual or auditory working memory task) | 902 MHz | 0.738–1.18 W/kg | continuous for about 54 or 80 min | mobile phone, mobile communications, CW continuous wave, PW pulsed wave |