Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Smitha CK et al. | 2013 | human, partial body: ear, head (Cz position) | effects on EEG | - | 0.987–1.3 W/kg | continuous for 5 min/position | mobile phone, mobile communications |
Roschke J et al. | 1997 | human, partial body: head | EEG | 900 MHz | - | continuous for nearly 3.5 min | GSM, mobile communications |
Reiser H et al. | 1995 | human, partial body: head | EEG | 150 kHz | - | continuous for 15 min | digital mobile phone, GSM, mobile communications, therapeutic/medical device |
Eulitz C et al. | 1998 | human, partial body: head | brain activity during an auditory discrimination task | 916.2 MHz | - | see add. information | mobile communications, digital mobile phone, GSM, PW pulsed wave |
Gehlen W et al. | 1996 | human, partial body: head | EEG, cognitive functions | 914.2 MHz | - | 10 min | mobile communications, digital mobile phone, PW pulsed wave |
Hietanen M et al. | 2000 | human, partial body: head | EEG | 900–1,800 MHz | 850 mW/g | repeated exposure trials for 30 min with 20 min of real exposure | analog mobile phone, digital mobile phone, GSM, NMT, mobile communications |
Urban P et al. | 1998 | human, partial body: head | EEG (visual evoked potentials) | 900 MHz | - | continuous for 5 min | GSM, mobile communications |
Lebedeva NN et al. | 2000 | human, partial body: head | EEG | 902.4 MHz | - | continuous for 15 min | mobile communications, mobile phone |
Huber R et al. | 2002 | human, partial body: head | regional cerebral blood flow | 900 MHz | 1 W/kg | continuous for 30 min | GSM, mobile communications, PW pulsed wave |
Croft RJ et al. | 2002 | human, partial body: head | neural function/EEG | 900 MHz | - | continuous for 3 x 20 min | GSM, mobile communications |
D'Costa H et al. | 2003 | human, partial body: head | EEG | 900 MHz | - | intermittent for 10 x 5 min, see add. information | GSM, mobile communications |
Hamblin DL et al. | 2006 | human, partial body: head | neural function/activity | 895 MHz | 0.11 W/kg | continuous for about 21 min | GSM, mobile communications |
Nanou E et al. | 2005 | human, partial body: head | EEG during an auditory memory task | 900 MHz | - | continuous for about 45 min | mobile communications, mobile phone |
Krause CM et al. | 2006 | human, partial body: head | oscillatory EEG responses during cognitive processing in children | 902 MHz | 1.4–1.98 W/kg | continuous for 30 min | GSM, mobile communications |
Regel SJ et al. | 2007 | human, partial body: head | waking EEG, cognitive performance | 900 MHz | 1 W/kg | continuous for 30 min | digital mobile phone, GSM, mobile communications |
Trunk A et al. | 2013 | human, partial body: head | - | 1,947 MHz | 1.75–3.75 W/kg | continuous for 30 min | digital mobile phone, UMTS, mobile communications |
Tombini M et al. | 2013 | human, partial body: head | - | 902.4 MHz | 0.5 W/kg | continuous for two times 45 min (see add. information) | digital mobile phone, GSM, mobile communications, PW pulsed wave |
Loughran SP et al. | 2013 | human, partial body: head | waking EEG, cognitive performance | 900 MHz | 0.35–1.4 W/kg | continuous for 30 min | mobile phone, GSM, mobile communications, PW pulsed wave |
Lustenberger C et al. | 2013 | human, partial body: head | brain activity during sleep | 900 MHz | 0.125–10 W/kg | intermittent during 8 h (during the sleep; exposure of 5 min "Intermittent-1" was followed by 1 min with no exposure (OFF phase), then 5 min "Intermittent-2" was followed by a 7 min OFF phase; this 18 min sequence was repeated throughout the whole night | mobile phone, mobile communications, RF field |
Trunk A et al. | 2014 | human, partial body: head | - | - | 0.73–2 W/kg | - | mobile phone, UMTS, mobile communications, co-exposure |
Curcio G et al. | 2015 | human, partial body: head | cortical activity (EEG) | 902.4 MHz | 0.5 W/kg | continuous for 45 min | mobile phone, GSM, mobile communications |
Ghosn R et al. | 2015 | human, partial body: head | alpha waves in the resting EEG | 900 MHz | 0.49–0.93 W/kg | continuous for 26 minutes | mobile phone, GSM, mobile communications |
Eggert T et al. | 2015 | human, partial body: head | effects on EEG slow waves | 385 MHz | 1.5–6 W/kg | continuous for 2.5 hours | TETRA/TETRAPOL, mobile communications |
Hamblin DL et al. | 2004 | human, partial body: head (ear) | event-related potentials and performance during an auditory task | 894.6 MHz | 0.87 W/kg | continuous for 1 h | digital mobile phone, GSM, mobile communications |
Freude G et al. | 2000 | human, partial body: head (left ear) | EEG (slow brain potentials) | 916.2 MHz | 0.882–1.42 mW/g | continuous for about 3 to 4 min per task | GSM, mobile communications |