Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Nam KC et al. | 2009 | human, partial body: head | pulse rate, heart rate variability, heart rate, respiratory rate, subjective symptoms, perception of radiofrequency exposure | 824.64–848.37 MHz | 1.22 W/kg | continuous for 30 min | mobile communications, digital mobile phone, CDMA |
Augner C et al. | 2012 | human | physiological measures (heart rate, heart rate variability, blood pressure), subjective symptoms (headache, nausea, fatigue, dizziness, skin irritation) | 835–1,800 MHz | - | 5-180 min | mobile phone, GSM, NMT, mobile communications |
Wdowiak A et al. | 2018 | human | - | 880 MHz–2.43 GHz | - | - | mobile communications, mobile phone, GSM, mobile phone base station, UMTS, W-LAN/WiFi, DECT, also other exposures without EMF, personal |
Hillert L et al. | 2008 | human, partial body: head (left side) | electromagnetic field perception and symptoms (headache, vertigo, skin irritation and sensation of heat) | 884 MHz | 0.18–1.8 W/kg | continuous for 3 h | digital mobile phone, GSM, mobile communications |
Eltiti S et al. | 2007 | human, whole body | well-being | 886.8–1,879 MHz | - | continuous for 5, 15, and 50 min | mobile phone base station, GSM, UMTS, mobile communications |
Cinel C et al. | 2008 | human, partial body: left or right side of the head | subjective symptoms | 888 MHz | 1.4–11.2 W/kg | continuous for 40 min | digital mobile phone, GSM, mobile communications |
Braune S et al. | 1998 | human, partial body: head (right side) | blood pressure, heart rate, capillary perfusion, well-being | 900 MHz | - | continuous for 35 min | digital mobile phone, GSM, mobile communications |
Hietanen M et al. | 2002 | human, partial body: head | electromagnetic hypersensitivity symptoms or sensations | 900 MHz | - | repeated exposure for less than 30 min, see add. information | analog mobile phone, digital mobile phone, GSM, NMT, mobile communications |
Radon K et al. | 1998 | human, whole body | perception of electromagnetic fields | 900 MHz | - | repeated exposure with intermittent stimulus (3 x 2 min on/10 s off) for 12 times in one day | GSM, mobile communications |
Wilen J et al. | 2006 | human, partial body: head | physiological and cognitive responses | 900 MHz | 0.8–1 W/kg | continuous for 30 min | GSM, mobile communications |
Rubin GJ et al. | 2006 | human, partial body: head (left ear) | subjective complaints (e.g. headaches, fatigue, nausea, dizziness, sensation of warmth, eye pain) | 900 MHz | 1.4 W/kg | continuous for 50 min | GSM, mobile communications, mobile phone |
Kleinlogel H et al. | 2008 | human, partial body: left ear | EEG, well-being | 0.9 GHz | 0.1–1 W/kg | continuous for about 30 min | digital mobile phone, GSM, UMTS, mobile communications |
Augner C et al. | 2009 | human, whole body | psychological symptoms and health concerns | 900 MHz | - | intermittent, 5 x 50 min, with 5-min breaks | mobile phone base station, GSM, mobile communications |
Eltiti S et al. | 2009 | human, whole body | cognitive functioning: short-term memory, attention and perceptual motor speed, working memory, blood volume pulse, heart rate, skin conductance | 900–1,800 MHz | - | continuous for 50 min | mobile phone base station, GSM, UMTS, mobile communications |
Huang PC et al. | 2022 | human | - | 900–2,100 MHz | - | - | mobile phone base station, mobile communications, GSM |
Koivisto M et al. | 2001 | human, partial body: head (left side) | subjective symptoms or sensations | 902 MHz | - | 1 session of 30 min or 2 sessions of 60 min each separated by 24 h | digital mobile phone, GSM, mobile communications |
Kwon MS et al. | 2008 | human, partial body: ear | electrosensibility | 902 MHz | 0.82–1.21 W/kg | intermittent, 5 s on or off and a pause for reaction plus 1 s, repeated 100 times | digital mobile phone, GSM, mobile communications |
Verrender A et al. | 2018 | human, whole body | symptoms and field perception | 902–928 MHz | - | 30 min each exposure (6 x in double-blind study) | GSM, UMTS, mobile communications, RF field, W-LAN/WiFi |
Verrender A et al. | 2018 | human | - | 902–928 MHz | - | - | mobile communications, RF field, W-LAN/WiFi |
Oftedal G et al. | 2007 | human, partial body: head | headache | 902.4 MHz | 0.8–1 W/kg | continuous for 30 min | digital mobile phone, GSM, mobile communications |
Stovner LJ et al. | 2008 | human, partial body: head | headache | 902.4 MHz | 1 W/kg | continuous for 30 min | mobile phone, digital mobile phone, GSM, mobile communications, RF field |
Zwamborn APM et al. | 2003 | human, whole body | cognitive performance, well-being | 945 MHz | 0.000316 µW/kg–0.082 mW/kg | continuous for 20 min | mobile phone base station, GSM, UMTS, CDMA, TDMA, mobile communications |
Malek F et al. | 2015 | human, whole body | physiological changes and cognitive performance | 945 MHz | - | not specified | mobile phone base station, GSM, UMTS, mobile communications |
Kwon MK et al. | 2012 | human, partial body: head | - | 1,950 MHz | 1.6 W/kg | continuous for 32 min | digital mobile phone, W-CDMA, mobile communications, microwaves |
Kwon MK et al. | 2012 | human, partial body: head | - | 1,950 MHz | 1.57 W/kg | - | mobile phone, W-CDMA, mobile communications |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.