Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Parizek D et al. | 2023 | human | - | 2,400–2,600 MHz | - | - | 4G, mobile communications, W-LAN/WiFi |
Braune S et al. | 2002 | human, partial body: head/right | blood pressure; heart rate, hormonal parameters (changes in hormone levels) | 900 MHz | 0.5–0.84 W/kg | continuous for 50 min | GSM, mobile communications |
Tahvanainen K et al. | 2004 | human, partial body: head (ear) | heart rate and blood pressure | 900 MHz | 0.7–1.58 W/kg | continuous for 35 min | GSM, mobile communications |
Wilen J et al. | 2006 | human, partial body: head | physiological and cognitive responses | 900 MHz | 0.8–1 W/kg | continuous for 30 min | GSM, mobile communications |
Parazzini M et al. | 2007 | human, partial body: head | autonomic nervous system response, heart rate variability | 900 MHz | 0.02 W/kg | continuous for 26 min | GSM, mobile communications |
Burgess AP et al. | 2016 | - | - | - | - | - | TETRA/TETRAPOL, mobile communications |
Nam KC et al. | 2006 | human, partial body: head (left side) | different physiological parameters (blood pressure, heart rate, respiration, skin resistance) | 835 MHz | 1.6 W/kg | continuous for 30 min | digital mobile phone, CDMA, mobile communications |
Barutcu I et al. | 2011 | human, partial body: left precordial area | cardiac autonomic modulation (heart rate variability) | 900–1,800 MHz | - | three times 5 min (see add. information) | digital mobile phone, GSM, TDMA, mobile communications |
Barker AT et al. | 2007 | human, partial body: head (left side) | blood pressure, heart rate variability | - | 1.3 W/kg | continuous for 40 min | digital mobile phone, GSM, TETRA/TETRAPOL, mobile communications |
Braune S et al. | 1998 | human, partial body: head (right side) | blood pressure, heart rate, capillary perfusion, well-being | 900 MHz | - | continuous for 35 min | digital mobile phone, GSM, mobile communications |
Mann K et al. | 1998 | human, partial body: head/vertex | heart rate variability | 900 MHz | - | continuous for 8 h | digital mobile phone, GSM, mobile communications |
Mann K et al. | 2005 | human, partial body: head (vertex) | heart rate variability | 900 MHz | - | continuous for 8 h | digital mobile phone, GSM, mobile communications |
Atlasz T et al. | 2006 | human, partial body | heart rate, heart rate variability | 900 MHz | 1.3 W/kg | continuous for 10 min | digital mobile phone, GSM, mobile communications |
Yilmaz D et al. | 2010 | human, partial body: right ear | heart rate variability | 900 MHz | 0.56 W/kg | 21 minutes (7 minutes real exposure and 2 x 7 minutes exposure by standy-by mode) | digital mobile phone, GSM, mobile communications |
Mortazavi SM et al. | 2011 | human | - | - | - | continuous for 10 min | digital mobile phone, GSM, mobile communications, microwaves |
Kwon MK et al. | 2011 | human, partial body: left side of the head | heart rate, heart rate variability, respiratory rate | 1,950 MHz | 1.57 W/kg | continuous for 32 min | digital mobile phone, W-CDMA, mobile communications |
Kwon MK et al. | 2012 | human, partial body: head | - | 1,950 MHz | 1.6 W/kg | continuous for 32 min | digital mobile phone, W-CDMA, mobile communications, microwaves |
Béres S et al. | 2018 | human, partial body | - | 1,800 MHz | - | - | mobile communications, GSM |
Andrianome S et al. | 2017 | human | - | 900 MHz–2.45 GHz | - | - | mobile communications, GSM, W-LAN/WiFi, DECT, RF, 2.45 GHz |
Misek J et al. | 2018 | human, partial body | - | 1,788 MHz | - | - | mobile communications, PW pulsed wave |
Misek J et al. | 2017 | human, partial body | - | 1,788.5 MHz | - | - | mobile communications, RF, PW pulsed wave |
Wallace D et al. | 2010 | human, whole body | electrosensitivity (well-being and different physiological responses) | 420 MHz | 271 µW/kg | continuous for 15 min for the open provocation test, 2 times 5 min for the doble blind test | mobile communications, TETRA/TETRAPOL, TDMA, RF |
Nam KC et al. | 2009 | human, partial body: head | pulse rate, heart rate variability, heart rate, respiratory rate, subjective symptoms, perception of radiofrequency exposure | 824.64–848.37 MHz | 1.22 W/kg | continuous for 30 min | mobile communications, digital mobile phone, CDMA |
Curcio G et al. | 2009 | human, partial body: left ear | hemodynamics (oxygenation) of the frontal cortex | 902.4 MHz | 5 W/g | 40 min | mobile communications, digital mobile phone, GSM |
Colak C et al. | 2012 | animal, rat/Wistar, whole body | ECG, blood pressure, heart rate | 1.9–2.2 GHz | - | 40 min/day for 20 days | mobile communications, digital mobile phone, co-exposure |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.