Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Epidemiological studies on power frequency fields (50/60 Hz)

528 studies in total
  1. 103 studies
  2. 85 studies
  3. 85 studies
  4. 81 studies
  5. 65 studies
  6. 64 studies
  7. 63 studies
  8. 62 studies
  9. 61 studies
  10. 31 studies
Authors Year Study type Study group Observation period Study location Endpoints Parameters
Nielsen CV et al. 1992 case-control study women, children in utero, newborns 1984 - 1985 Denmark low birthweight, preterm birth, infant mortality electric field, magnetic field, 50/60 Hz, PC/TV monitor, occupational
Gracia CR et al. 2005 case-control study men 1991 - 1997 USA male infertility magnetic field, 50/60 Hz, PC/TV monitor, EMF general, occupational, also other exposures without EMF, not extractable
Lee GM et al. 2002 case-control study women, children in utero March1990 - April 1991 USA miscarriage magnetic field, 50/60 Hz, power transmission line, residential, personal
Li DK et al. 2002 cohort study, prospective cohort study women, children in utero October 1996 - October 1998 USA miscarriage magnetic field, low frequency, 50/60 Hz, power transmission line, other domestic appliance, occupational, residential, personal
Wang Q et al. 2013 cohort study women, children in utero May 2010 - May 2012 China miscarriage magnetic field, 50/60 Hz, power transmission line, electrical substation, residential
Li DK et al. 2017 cohort study women, children in utero, ≥ 18 years not stated USA miscarriage magnetic field, low frequency, 50/60 Hz
Parazzini F et al. 1993 meta-analysis women, children in utero, newborns 1976 - 1987 USA, Canada, Sweden, Denmark, Finland miscarriage, low birth weight, and congenital malformation magnetic field, 50/60 Hz, PC/TV monitor, occupational
Savitz DA et al. 1994 case-control study women, children in utero, newborns 1976 - 1983 USA miscarriage, low birth weight, preterm delivery magnetic field, 50/60 Hz, power transmission line, residential
Goldhaber MK et al. 1988 case-control study women, children in utero, newborns 1981 - 1982 USA miscarriages, birth defects magnetic field, 50/60 Hz, PC/TV monitor, occupational
Shaw GM et al. 1999 case-control study women, children in utero, newborns 1989 - 1991 USA neural tube defect and orofacial cleft magnetic field, 50/60 Hz, electric blanket, other domestic appliance, personal
Savitz DA et al. 2006 cross-sectional study women 2003 - 2004 USA physical activity in pregnancy magnetic field, 50/60 Hz, power transmission line, other domestic appliance, personal
Perry S et al. 1988 - men, women - UK pregnancy complications, cardiovascular diseases, all cancer, neurodegenerative diseases, depression, schizophrenia magnetic field, 50/60 Hz, inhouse wiring, residential
Migault L et al. 2018 cohort study women, children in utero, newborns 2011, follow-up at the child's age of 2 months France premature birth between 33 and 37 weeks of gestation, small for gestational age magnetic field, low frequency, 50/60 Hz, occupational, residential
Migault L et al. 2020 pooled analysis women, children in utero, newborns 2011 France prematurity and small for gestational age magnetic field, low frequency, 50/60 Hz, occupational, residential
Sadeghi T et al. 2017 case-control study women, children in utero 2013 - 2014 Iran preterm birth, birth defect, newborn death power transmission line, 50/60 Hz, magnetic field, residential
Auger N et al. 2011 - women, children in utero, newborns 1990 - 2004 Canada preterm birth, low birth weight, small-for-gestational-age birth, and infant sex magnetic field, 50/60 Hz, power transmission line, residential
de Vocht F et al. 2014 cohort study women, children in utero, newborns 2004 - 2008 UK preterm birth, spontaneous preterm birth, small for gestational age, low birthweight (< 2500g), birth weight electric field, magnetic field, 50/60 Hz, power transmission line, underground cable, electrical substation, residential
Mahram M et al. 2013 cohort study women, children in utero, newborns 2011 Iran preterm delivery, duration of pregnancy, caesarean section, cause for caesarean section, birth weight and length, head circumference at birth, congenital abnormalities magnetic field, 50/60 Hz, power transmission line, residential
Grajewski B et al. 1997 cross-sectional study women, children in utero, newborns 1983 - 1986 USA reduced birthweight and preterm birth magnetic field, 50/60 Hz, PC/TV monitor, intermediate frequency, occupational
Irgens A et al. 1997 cohort study men, women, children in utero, newborns 1970 - 1993 Norway sex ratio, male proportion of offspring magnetic field, static magnetic field, 50/60 Hz, high volt./current device/welder, occupational
McDonald AD et al. 1986 - women, children in utero, newborns 1982 - 1984 Canada spontaneous a.bortion, congenital defects magnetic field, 50/60 Hz, PC/TV monitor, occupational
Schnorr TM et al. 1991 cohort study women, children in utero 1983 - 1986 USA spontaneous abortion magnetic field, 50/60 Hz, PC/TV monitor, occupational
Lindbohm ML et al. 1992 case-control study women, children in utero 1975 - 1985 Finland spontaneous abortion magnetic field, 50/60 Hz, PC/TV monitor, occupational
Grasso P et al. 1997 case-control study women 1992 - 1995 Italy spontaneous abortion magnetic field, 50/60 Hz, PC/TV monitor, personal
Belanger K et al. 1998 cohort study women 1988 - 1991 USA spontaneous abortion magnetic field, 50/60 Hz, power transmission line, electric blanket, other domestic appliance, residential, personal