Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Mahato S et al. | 2023 | isolated bio./chem. substance, myofibrillar protein from grass carp | magnetic field, 50/60 Hz, low frequency, also other exposures without EMF, co-exposure | - |
Ramazi S et al. | 2023 | intact cell/cell culture, MCF-7 (human breast cancer cell line) and HFF cells (human foreskin fibroblast cells) | magnetic field, 50/60 Hz, also other exposures without EMF, co-exposure | - |
Nakanishi R et al. | 2023 | intact cell/cell culture, C2C12 cells (undifferentiated mouse myoblasts), animal, C57BL/6 mouse | magnetic field, 50/60 Hz | - |
Sendera A et al. | 2024 | intact cell/cell culture, human adipose-derived mesenchymal stem cells | magnetic field, 50/60 Hz, low frequency | - |
Guzmán-Armenteros TM et al. | 2024 | bacterium, microbial fermentation organism | magnetic field, 50/60 Hz | - |
Kilfoyle AK et al. | 2018 | animal, fish, whole body | magnetic field, static magnetic field, high-voltage direct current (HVDC), underground cable, 50/60 Hz, DC | 0.4–559 nT |
Prato FS et al. | 2009 | animal, mouse/CD-1, whole body | magnetic field, static magnetic field, 50/60 Hz, co-exposure, shielding/field deprivation | 0.001–0.35 µT |
Prato FS et al. | 2013 | animal, mouse/Swiss CD1, whole body | magnetic field, static magnetic field, low frequency, 50/60 Hz | 33 nT–44 µT |
Boscolo P et al. | 2001 | human, whole body | electric field, magnetic field, 50/60 Hz | 200 nT–3.6 µT |
Thompson JM et al. | 1995 | animal, sheep/Suffolk (lambs), whole body | electric field, magnetic field, 50/60 Hz, power transmission line | 0.28–7.9 µT |
Prato FS et al. | 2011 | animal, mouse/CD-1, whole body | magnetic field, low frequency, 50/60 Hz | 300–500 nT |
Scalenghe R | 2007 | soil microorganisms and soil samples | magnetic field, 50/60 Hz, power transmission line | 0.5–42.5 µT |
Touitou Y et al. | 2012 | human, whole body | magnetic field, 50/60 Hz, power transmission line, electrical substation, occupational, residential | 0.64–0.82 µT |
Nikin B et al. | 1994 | human, whole body | magnetic field, 50/60 Hz, occupational | 1–35 µT |
Harris AW et al. | 1998 | animal, mouse/Eµ-<i>Pim1</i> transgenic strain and nontransgenic strain C57BL/6NTac, whole body | magnetic field, 50/60 Hz | 1 µT–1 mT |
Fernie KJ et al. | 2000 | animal, bird/American kestrel (<i>Falco sparverius</i>), whole body | electric field, magnetic field, 50/60 Hz, power transmission line | 1.2–30 µT |
Kirschvink J et al. | 1997 | invertebrate, honeybee (<i>Apis mellifera carnica</i>) | magnetic field, low frequency, 50/60 Hz | 1.3–1,300 µT |
Dell'Omo G et al. | 2009 | animal, kestrel/Eurasian (<i>Falco tinnunculus</i>), whole body | electric field, magnetic field, 50/60 Hz, power transmission line | 1.37–25.16 µT |
Thomson RA et al. | 1988 | animal, mouse/DBA/2 (partially implanted with P388 leukemia cells), whole body | magnetic field, 50/60 Hz | 1.4–500 µT |
Caprani A et al. | 2004 | intact cell/cell culture, EA.hy926 cells (human endothelial cell line) | electric field, magnetic field, 50/60 Hz, inhouse wiring, residential | 1.8–25 µT |
Kim HS et al. | 2014 | animal, mouse/BALB/c, whole body | magnetic field, 50/60 Hz | 2–200 µT |
House RV et al. | 1996 | animal, mouse/B6 C3 F1, mouse/BALB/c and rat/Fischer 344, whole body | magnetic field, 50/60 Hz | 0.002–1 mT |
Boorman GA et al. | 1997 | animal, rat/F344/N and mouse/B6C3F1, whole body | magnetic field, 50/60 Hz | 2–1,000 µT |
Mandeville R et al. | 1997 | animal, rat/Fischer 344, whole body | magnetic field, 50/60 Hz | 2–2,000 µT |
Anselmo CW et al. | 2006 | animal, rat/Wistar, whole body: during pregnancy | magnetic field, 50/60 Hz | 3 µT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.