Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Parameters | Electric field strength |
---|---|---|---|---|---|
Nurhidayat L et al. | 2022 | animal, rat/Sprague Dawley | - | intermediate frequency, electric field, static electric field, co-exposure | - |
Bailey WH et al. | 1986 | animal, rat/Sprague-Dawley (Holtzman line), whole body | - | static electric field, DC, co-exposure | 30–120 V/cm |
Marino AA et al. | 1974 | animal, rat/Sprague-Dawley and mouse/Swiss Ha/ICR, whole body | - | static electric field | 3–197 V/cm |
Cieslar GJ et al. | 2009 | animal, rat/Wistar albino | - | static electric field, DC, power transmission line, high-voltage direct current (HVDC) | 25 kV/m |
Okudan B et al. | 2006 | animal, rat/Wistar albino, whole body | bone mineral content and bone mineral density | electric field, static electric field, 50/60 Hz | 10 kV/m |
Aslan A et al. | 2021 | animal, rat/Wistar albino, whole body | effects on bone healing | electric field, static electric field, 50/60 Hz | 5–10 kV/m |
Harutyunyan H et al. | 2013 | animal, rat/albino | - | static electric field | 200 kV/m |
Harutyunyan HA et al. | 2016 | animal, rat/albino, whole body | - | static electric field, DC | 200 kV/m |
Sahakyan G et al. | 2015 | animal, rat/white, whole body | - | static electric field, DC | 200 kV/m |
Kanemaki M et al. | 2022 | blood samples | - | electric field, static electric field, low frequency, 50/60 Hz | - |
Newland PL et al. | 2015 | excised wings, <i>Drosophila melanogaster</i>/Oregon-R (wildtype), invertebrate, <i>Drosophila melanogaster</i>/Oregon-R (wildtype), whole body | - | static electric field, DC | 28–183 kV/m |
Oftedal G et al. | 1995 | human | - | electric field, magnetic field, static magnetic field, static electric field, low frequency, intermediate frequency, PC/TV monitor, occupational, shielding/field deprivation | 0–5 kV/m |
Omura Y et al. | 1993 | human | - | electric field, static electric field, 50/60 Hz, also other exposures without EMF | 20–30 V/m |
Skulberg KR et al. | 2001 | human | - | electric field, static electric field, low frequency, intermediate frequency, 50/60 Hz, DC, PC/TV monitor | 0–31.5 kV/m |
Jankowiak K et al. | 2022 | human | - | electric field, static electric field, 50/60 Hz, high-voltage direct current (HVDC), power transmission line, co-exposure | - |
Kursawe M et al. | 2023 | human | - | electric field, static electric field, high-voltage direct current (HVDC), 50/60 Hz, co-exposure | - |
Shimizu HO et al. | 2014 | human, partial body: forearm | - | static electric field, DC | - |
Blondin JP et al. | 1996 | human, whole body | perception of local direct current electric fields | static electric field, DC, high-voltage direct current (HVDC) | 17.5–50 kV/m |
Puharich HK | 1966 | human, whole body | - | electric field, static electric field, DC | - |
Barron CI et al. | 1964 | human, whole body | - | static electric field, co-exposure | 1,000 V/m |
Jankowiak K et al. | 2021 | human, whole body | field perception and subjective sensations | static electric field, electric field, 50/60 Hz, power transmission line, high-voltage direct current (HVDC), co-exposure | 4–44 kV/m |
Kursawe M et al. | 2021 | human, whole body | detection threshold | static electric field, electric field, low frequency, 50/60 Hz, power transmission line, high-voltage direct current (HVDC), co-exposure | 2–44 kV/m |
Griffin M et al. | 2011 | intact cell/cell culture, human mesenchymal stem cells | - | magnetic field, static electric field, low frequency, signals/pulses, electric current application, DC, electrotherapy | 10 V/m |
Wang H et al. | 2024 | intact cell/cell culture, primary hepatocytes, animal, mouse/BALB/c | - | static magnetic field, static electric field, co-exposure, also other exposures without EMF | - |
Matsuda Y et al. | 2021 | invertebrate | - | static electric field | - |