Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on static electric fields

212 studies in total
  1. 121 studies
  2. 93 studies
  3. 23 studies
  4. 19 studies
  5. 13 studies
  6. 12 studies

Health 93 studies in total

Authors Year Exposed system Endpoints Parameters Electric field strength
Okudan B et al. 2006 animal, rat/Wistar albino, whole body bone mineral content and bone mineral density electric field, static electric field, 50/60 Hz 10 kV/m
Edwards DK 1960 invertebrate, <i>Drosophila melanogaster</i> and <i>Calliphora vicina</i> - static electric field 10–65.7 kV/m
Blondin JP et al. 1996 human, whole body perception of local direct current electric fields static electric field, DC, high-voltage direct current (HVDC) 17.5–50 kV/m
Möse JR et al. 1970 animal, rat and guinea pig, whole body - static electric field 238 V/cm
Möse JR et al. 1970 animal, rat and guinea pig, whole body - static electric field 238 V/cm
Möse JR et al. 1971 animal, mouse/white - static electric field 23.8 kV/m
Cieslar GJ et al. 2009 animal, rat/Wistar albino - static electric field, DC, power transmission line, high-voltage direct current (HVDC) 25 kV/m
Newland PL et al. 2015 excised wings, <i>Drosophila melanogaster</i>/Oregon-R (wildtype), invertebrate, <i>Drosophila melanogaster</i>/Oregon-R (wildtype), whole body - static electric field, DC 28–183 kV/m
Gromyko NM et al. 1992 animal, rat/ Wistar, whole body - static electric field, co-exposure 30–160 kV/m
Di G et al. 2018 animal, mouse/ICR, whole body number and proportion of blood cells electric field, static electric field, 50/60 Hz 35 kV/m
Dong L et al. 2022 animal, mouse/ICR, whole body oxidative stress in the spleen of mice, ultrastructural changes in the spleen of mice static electric field, high-voltage direct current (HVDC) 56.3 kV/m
Creim JA et al. 1995 animal, rat/Long-Evans - DC, high-voltage direct current (HVDC) 75 kV/m
Harutyunyan H et al. 2013 animal, rat/albino - static electric field 200 kV/m
Harutyunyan HA et al. 2016 animal, rat/albino, whole body - static electric field, DC 200 kV/m
Sahakyan G et al. 2015 animal, rat/white, whole body - static electric field, DC 200 kV/m
Kato M et al. 1986 animal, cat, partial body: leg - static electric field, DC 240–310 kV/m
Fam WZ 1981 animal, mouse/ICR-SW - static electric field, DC 340 kV/m
Gray JR et al. 2000 animal, mouse/B6C3F1, whole body - static magnetic field, static electric field 450 kV/m