With baby monitors, infants can be monitored acoustically. Thereby a transmitter records the sound of the children and transmits it via radio technology to a mobile receiver. The receiver is equipped with loudspeakers and reproduces the sound.
Measurand | Value | Feature | Remarks |
---|---|---|---|
electric field strength | 0.8 V/m (measured) | - | at a distance of 100 cm [2] |
electric field strength | 1.1 V/m (measured) | - | at a distance of 70 cm [2] |
electric field strength | 2.43 V/m (measured) | - | at a distance of 50 cm [2] |
SAR | 0.01 mW/kg (maximum, measured) | - | averaged over the whole body of a 1- and 2-year-old child at a distance of 100 cm [2] |
SAR | 0.1 mW/kg (maximum, calculated) | - | averaged over the whole body of a 1- and 2-year-old child at a distance of 50 cm [2] |
Measurand | Value | Feature | Remarks |
---|---|---|---|
electric field strength | 1.2 V/m (measured) | - | at a distance of 100 cm [2] |
electric field strength | 2.73 V/m (measured) | - | at a distance of 70 cm [2] |
electric field strength | 5.02 V/m (measured) | - | at a distance of 50 cm [2] |
power density | 0.032 mW/m² (measured) | - | at a distance of 3 m [1] |
power density | 0.424 mW/m² (measured) | - | at a distance of 1 m [1] |
SAR | 0.02 mW/kg (measured) | - | averaged over the whole body of a 1- and 2-year-old child at a distance of 100 cm [2] |
SAR | 0.33 mW/kg (maximum, calculated) | - | averaged over the whople body of a 2-year-old child at a distance of 50 cm [2] |
SAR | 0.34 mW/kg (maximum, calculated) | - | averaged over the whole body of a 1-year-old child at a distance of 50 cm [2] |
Measurand | Value | Feature | Remarks |
---|---|---|---|
magnetic flux density | 0.1 µT (mean, measured) | - | at a distance of 30.48 cm [3] |
magnetic flux density | 0.2 µT (maximum, measured) | - | at a distance of 30.48 cm [3] |
magnetic flux density | 0.4–1.5 µT (measured) | - | at a distance of 15.24 cm [3] |
magnetic flux density | 0.6 µT (mean, measured) | - | at a distance of 15.24 cm [3] |
SAR | 0.08 W/kg (maximum, measured) | - | averaged over 10 g of tissue at a distance of 1 m to the device [4] |
power | ≤ 500 mW | - | maximum transmit power [4] |