Study overviews

Mobile phone related articles are

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on mobile communications

1699 studies in total
  1. 738 studies
  2. 563 studies
  3. 512 studies
  4. 221 studies
  5. 204 studies
  6. 118 studies

Brain

512 studies in total
  1. 154 studies
  2. 148 studies
  3. 142 studies
  4. 80 studies
  5. 35 studies
  6. 35 studies
  7. 18 studies

Blood-brain barrier permeability 35 studies in total

Authors Year Exposed system Endpoints Frequency range SAR Exposure duration Parameters
Eberhardt JL et al. 2008 animal, rat/Fischer 344, whole body blood-brain barrier permeability and nerve cell damage 900 MHz 0.12–120 mW/kg continuous for 2 h mobile phone, GSM, mobile communications
Sirav B et al. 2016 animal, rat/Wistar albino, whole body permeability of the blood brain barrier 900 MHz 0.02 W/kg continuous for 20 minutes mobile phone, GSM, mobile communications
Finnie JW et al. 2009 animal, mouse, whole body aquaporin-4 expression in the brain (as marker for blood-brain barrier permeability) 900 MHz 4 W/kg continuous for 60 min mobile phone, GSM, mobile communications, PW pulsed wave
McQuade JM et al. 2009 animal, rat/Fischer 344 CD-VAF, whole body permeability of blood-brain barrier 915 MHz 0.0018–20 W/kg continuous for 30 min mobile phone, GSM, mobile communications, RF field, CW continuous wave, PW pulsed wave
Nittby H et al. 2009 animal, rat/Fischer 344, whole body blood-brain barrier permeability and neuronal damage 915 MHz 0.12–120 mW/kg continuous for 2 hr mobile phone, GSM, mobile communications, microwaves
Grafstrom G et al. 2008 animal, rat/Fischer 344, whole body neuronal damage, blood-brain barrier permeability and effects on ageing process and memory 900 MHz 0.6–60 mW/kg 2 hr/week for 55 weeks mobile phone, digital mobile phone, GSM, mobile communications
de Gannes FP et al. 2009 animal, rat/Fischer 344, partial body: head permeability of blood-brain barrier and neuron degeneration 900 MHz 0.14–2 W/kg continuous for 2 hr mobile phone, digital mobile phone, GSM, mobile communications
Tang J et al. 2015 animal, rat/Sprague-Dawley, partial body: head relationship between memory function, blood brain barrier permeability and the mkp-1/ERK pathway in the rat brain 900 MHz 0.016–2 W/g continuous for 3 h/day for 14 days mobile phone, mobile communications
Soderqvist F et al. 2015 human, partial body: right head side blood brain barrier permeability 890 MHz 0.2–2 W/kg continuous for 1 hour mobile phone, mobile communications
Poulletier de Gannes F et al. 2017 animal, rat/Wistar-Han, partial body - 1,800–1,960 MHz - - mobile phone, mobile communications, GSM, UMTS