Study overviews

Mobile phone related articles are

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on mobile communications

1696 studies in total
  1. 738 studies
  2. 561 studies
  3. 511 studies
  4. 220 studies
  5. 204 studies
  6. 118 studies

Brain

511 studies in total
  1. 153 studies
  2. 148 studies
  3. 142 studies
  4. 79 studies
  5. 35 studies
  6. 35 studies
  7. 18 studies
Authors Year Exposed system Endpoints Frequency range SAR Exposure duration Parameters
Arendash GW et al. 2012 animal, mouse/56.25% C57, 12.5% B6, 18.75% SJL, and 12.5% Swiss-Webster - 918 MHz 0.25–1.05 W/kg 2 h/day (early morning and late afternoon) for 2 months (study I) or 12 days (study II) mobile phone, GSM, mobile communications, PW pulsed wave, therapeutic/medical device
Bouji M et al. 2012 animal, rat/Sprague-Dawley, partial body: head astrocyte activation (glial fibrillary acidic protein (GFAP)), pro-inflammatory cytokine expression (interleukin), stress (corticosterone), emotional memory 900 MHz 6 W/kg continuous for 15 min digital mobile phone, GSM, mobile communications, PW pulsed wave
Mortazavi SM et al. 2012 human, partial body: right ear visual reaction time - 1.23 W/kg 5 x 10 min. (in random order with sham exposure and 30 min. rest in between) mobile phone, GSM, mobile communications
Aldad TS et al. 2012 animal, mouse/CD-1, whole body electrophysiological changes, memory 800–1,900 MHz 1.6 W/kg continuous for 0, 9, 15 or 24 hours/day on day 1-17 of gestation mobile phone, GSM, mobile communications
Cammaerts MC et al. 2012 invertebrate, ant (<i>Myrmica sabuleti</i>), whole body association between food sites and olfactory or visual cues 900 MHz - see add. information digital mobile phone, mobile phone base station, GSM, mobile communications
Vecchio F et al. 2012 human, partial body: left side of the head cortical activity (EEG), visual reaction time task 902.4 MHz 0.5 W/kg continuous for 45 min digital mobile phone, GSM, mobile communications, PW pulsed wave
Barth A et al. 2012 human, partial body: left or right side of the head cognitive performance 800–1,900 MHz - continuous for 25-1305 min or 3 times 15 min or 28 times 120 min digital mobile phone, GSM, UMTS, mobile communications, PW pulsed wave, theoretical/in silico study
Curcio G et al. 2012 human, partial body: right ear brain BOLD (blood-oxygen-level dependent) response, somatosensory reaction time task 902.4 MHz 0.212–1.25 W/kg continuous for 45 min digital mobile phone, GSM, mobile communications, PW pulsed wave
Wallace D et al. 2012 human, whole body cognitive function 420 MHz 217 µW/kg 25 min in session 1 (1 x 15 min and 2 x 5 min), 50 min each in session 2 and 3 mobile communications, mobile phone base station, TETRA/TETRAPOL, TDMA
Schmid MR et al. 2012 human, partial body: left side of the head working memory, attention, reaction time, polysomnography 900 MHz 2 W/kg continuous for 30 min. GSM, mobile communications, PW pulsed wave