Study overviews

Mobile phone related articles are

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on mobile communications

1694 studies in total
  1. 736 studies
  2. 560 studies
  3. 510 studies
  4. 220 studies
  5. 204 studies
  6. 118 studies

Health

736 studies in total
  1. 146 studies
  2. 90 studies
  3. 85 studies
  4. 80 studies
  5. 73 studies
  6. 61 studies
  7. 58 studies
  8. 54 studies
  9. 53 studies
  10. 47 studies
  11. 33 studies
  12. 25 studies
  13. 25 studies
  14. 19 studies
  15. 16 studies
  16. 10 studies
  17. 9 studies
  18. 4 studies

Hypersensitivity/well-being/subjective complaints 54 studies in total

Authors Year Exposed system Endpoints Frequency range SAR Exposure duration Parameters
Wilen J et al. 2006 human, partial body: head physiological and cognitive responses 900 MHz 0.8–1 W/kg continuous for 30 min GSM, mobile communications
Oftedal G et al. 2007 human, partial body: head headache 902.4 MHz 0.8–1 W/kg continuous for 30 min digital mobile phone, GSM, mobile communications
Stovner LJ et al. 2008 human, partial body: head headache 902.4 MHz 1 W/kg continuous for 30 min mobile phone, digital mobile phone, GSM, mobile communications, RF field
Furubayashi T et al. 2009 human, whole body mobile phone related symptoms (e.g. heart rate, psychological parameters, skin surface temperature) 2.14 GHz 0.0013–0.019 W/kg continuous for 30 min digital mobile phone, mobile phone base station, CDMA, mobile communications
Nam KC et al. 2009 human, partial body: head pulse rate, heart rate variability, heart rate, respiratory rate, subjective symptoms, perception of radiofrequency exposure 824.64–848.37 MHz 1.22 W/kg continuous for 30 min mobile communications, digital mobile phone, CDMA
Dorn H et al. 2014 human, partial body: head/ear warmth perception, skin temperature 385 MHz 1.5–6 W/kg continuous for 30 minutes TETRA/TETRAPOL, mobile communications, PW pulsed wave
Kim DW et al. 2008 human, partial body: head pulse rate, heart rate variability, heart rate, respiratory rate 824.64–848.37 MHz 1.6 W/kg continuous for 31 min mobile communications, mobile phone, CDMA
Kwon MK et al. 2012 human, partial body: head - 1,950 MHz 1.6 W/kg continuous for 32 min digital mobile phone, W-CDMA, mobile communications, microwaves
Braune S et al. 1998 human, partial body: head (right side) blood pressure, heart rate, capillary perfusion, well-being 900 MHz - continuous for 35 min digital mobile phone, GSM, mobile communications
Cinel C et al. 2008 human, partial body: left or right side of the head subjective symptoms 888 MHz 1.4–11.2 W/kg continuous for 40 min digital mobile phone, GSM, mobile communications