Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on magnetic power frequency fields (50/60 Hz)

2101 studies in total
  1. 785 studies
  2. 654 studies
  3. 532 studies
  4. 429 studies
  5. 338 studies
  6. 215 studies

DNA, proteins, and oxidative stress

654 studies in total
  1. 264 studies
  2. 218 studies
  3. 190 studies
  4. 47 studies

Genotoxicity 218 studies in total

Authors Year Exposed system Parameters Magnetic flux density/field strength
Jin H et al. 2015 intact cell/cell culture, L123 cells (human lung epithelial cells) magnetic field, 50/60 Hz, co-exposure 1–2 mT
Nieminen V et al. 2022 intact cell/cell culture, MCF-7 (human breast cancer cell line) static magnetic field, magnetic field, 50/60 Hz, co-exposure, also other exposures without EMF -
Dees C et al. 1996 intact cell/cell culture, MCF-7 and T-47D cell lines (human breast cancer cell lines) magnetic field, 50/60 Hz, co-exposure 1.2–900 µT
Crocetti S et al. 2013 intact cell/cell culture, MCF-7 cells (human breast cancer cell line) and MCF-10 cells (human non-tumorigenic breast epithelial cell line) and C2C12 cells (mouse myoblast cell line) magnetic field, low frequency, signals/pulses, 50/60 Hz 2–5 mT
Miyakoshi J et al. 2000 intact cell/cell culture, MO54 cells (derived from a human malignant glioma) magnetic field, 50/60 Hz, co-exposure 5–400 mT
Miyakoshi J et al. 1997 intact cell/cell culture, MeWo cells (malignant melanoma cells) magnetic field, 50/60 Hz, also other exposures without EMF 400–500 mT
Miyakoshi J et al. 1996 intact cell/cell culture, MeWo cells (malignant melanoma cells) magnetic field, 50/60 Hz, co-exposure 400 mT
Jin YB et al. 2014 intact cell/cell culture, NIH3T3 cells (mouse fibroblast cell line), WI-38 cells (human lung fibroblast cells), L-132 (human embryonic lung tissue), MCF10A cells (human breast epithelial cells); partially transfected with a c-Myc or empty vector magnetic field, 50/60 Hz, co-exposure 1 mT
Jin YB et al. 2012 intact cell/cell culture, NIH3T3 cells (mouse fibroblasts) and WI38 cells (human lung fibroblasts), normal and transfected with a c-Myc-containing vector or with an empty vetor magnetic field, low frequency, 50/60 Hz, co-exposure 0.01–1 mT
Luukkonen J et al. 2011 intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) magnetic field, low frequency, 50/60 Hz, co-exposure 100 µT