Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on magnetic power frequency fields (50/60 Hz)

2045 studies in total
  1. 764 studies
  2. 633 studies
  3. 511 studies
  4. 414 studies
  5. 329 studies
  6. 207 studies

Brain

207 studies in total
  1. 90 studies
  2. 73 studies
  3. 40 studies
  4. 32 studies
  5. 7 studies
  6. 3 studies

Brain activity/EEG/evoked potentials 40 studies in total

Authors Year Exposed system Parameters Magnetic flux density/field strength
Bell GB et al. 1991 - magnetic field, 50/60 Hz -
Dowman R et al. 1989 animal, monkey/southern pig-tailed macaque (<i>Macaca nemestrina</i>), whole body electric field, magnetic field, 50/60 Hz 10–90 µT
Zhang Y et al. 2017 animal, mouse/ICR, whole body magnetic field, 50/60 Hz, static magnetic field 1 mT
Marino AA et al. 2002 animal, rabbit/New Zealand, whole body magnetic field, 50/60 Hz 250 µT
Marino AA et al. 2003 animal, rabbit/New Zealand, whole body magnetic field, 50/60 Hz 250 µT
Marino AA et al. 2003 animal, rabbit/New Zealand, whole body, partial body: front or back body half, head, eye magnetic field, 50/60 Hz 50–280 µT
Ossenkopp KP et al. 1988 animal, rat/Long-Evans Hooded, whole body magnetic field, 50/60 Hz 100 µT
Frilot 2nd C et al. 2009 animal, rat/Sprague-Dawley, whole body magnetic field, low frequency, 50/60 Hz 0.25 mT
Balassa T et al. 2013 animal, rat/Wistar (embryo and young animal), whole body magnetic field, 50/60 Hz 0.5–3 mT
Komaki A et al. 2014 animal, rat/Wistar albino, whole body magnetic field, 50/60 Hz 100 µT
Demir T et al. 2014 animal, rat/Wistar albino, whole body magnetic field, 50/60 Hz 5 mT
Rostami A et al. 2016 animal, rat/Wistar, whole body magnetic field, 50/60 Hz 4 mT
Marino AA et al. 2010 human, partial body: coronal plane magnetic field, 50/60 Hz, MRI 100–200 µT
Selitskii GV et al. 2000 human, partial body: hand magnetic field, 50/60 Hz 40 mT
Crasson M et al. 1999 human, partial body: head magnetic field, 50/60 Hz 100 µT
Crasson M et al. 2005 human, partial body: head magnetic field, 50/60 Hz 100 µT
Ghione S et al. 2005 human, partial body: head magnetic field, 50/60 Hz 40–80 µT
Carrubba S et al. 2007 human, partial body: head magnetic field, 50/60 Hz 200 µT
Legros A et al. 2015 human, partial body: head magnetic field, static magnetic field, 50/60 Hz, MRI, co-exposure 1.8–3 mT
Modolo J et al. 2017 human, partial body: head 50/60 Hz, magnetic field 3–7.6 mT
Davarpanah Jazi S et al. 2017 human, partial body: head magnetic field, 50/60 Hz 50 mT
Bell GB et al. 1992 human, partial body: head and upper chest magnetic field, 50/60 Hz, static magnetic field 78 µT
Graham C et al. 1999 human, whole body magnetic field, 50/60 Hz 28.3 µT
Korpinen L et al. 1996 human, whole body electric field, magnetic field, 50/60 Hz, power transmission line 1.4–6.6 µT
Gamberale F et al. 1989 human, whole body electric field, magnetic field, 50/60 Hz, power transmission line, occupational 23.3 µT
Cook MR et al. 1992 human, whole body electric field, magnetic field, 50/60 Hz 20 µT
Graham C et al. 1994 human, whole body electric field, magnetic field, 50/60 Hz 10–30 µT
Graham C et al. 1999 human, whole body magnetic field, 50/60 Hz, occupational 14.1–28.3 µT
Lyskov E et al. 2001 human, whole body magnetic field, 50/60 Hz 10 µT
Marino AA et al. 2004 human, whole body magnetic field, 50/60 Hz 100 µT
Carrubba S et al. 2007 human, whole body magnetic field, low frequency, 50/60 Hz 100 µT
Cvetkovic D et al. 2009 human, whole body magnetic field, low frequency, 50/60 Hz, 16 2/3 Hz (train) 20 µT
Legros A et al. 2012 human, whole body magnetic field, low frequency, 50/60 Hz 1,800 µT
Caccia MR et al. 1985 human, whole body, partial body: head magnetic field, 50/60 Hz, therapeutic/medical device 2.2 mT
Carrubba S et al. 2010 human, whole body: sagittal plane perpendicular to the field magnetic field, 50/60 Hz 1–5 µT
Todorovic D et al. 2015 invertebrate, longhorn beetle (<i>Morimus funereus</i>), partial body: left antenna magnetic field, 50/60 Hz 2–19 mT
Elmas O et al. 2015 isolated sciatic nerves, rat/ Wistar albino, animal, rat/ Wistar albino, whole body magnetic field, 50/60 Hz 0.3 mT
Zheng Y et al. 2019 tissue slices, brain, rat/Sprague-Dawley magnetic field, 50/60 Hz, low frequency 0.5–2 mT
Varro P et al. 2009 tissue slices, brain, rat/Wistar, animal, rat/Wistar, whole body magnetic field, 50/60 Hz 250–500 µT
Kim T et al. 2022 tissue slices, occipital neocortex, rat/Sprague Dawley magnetic field, 50/60 Hz, static magnetic field, DC, intermediate frequency, low frequency -