Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on static magnetic fields

2160 studies in total
  1. 948 studies
  2. 720 studies
  3. 447 studies
  4. 371 studies
  5. 341 studies
  6. 169 studies

Health

720 studies in total
  1. 181 studies
  2. 90 studies
  3. 85 studies
  4. 80 studies
  5. 74 studies
  6. 59 studies
  7. 44 studies
  8. 36 studies
  9. 33 studies
  10. 31 studies
  11. 27 studies
  12. 25 studies
  13. 25 studies
  14. 24 studies
  15. 19 studies
  16. 18 studies
  17. 16 studies
  18. 15 studies
  19. 2 studies
  20. 2 studies
  21. 2 studies
Authors Year Exposed system Parameters Magnetic flux density/field strength
Laszlo JF et al. 2012 animal, large garden snail (<i>Helix pomatia</i>) static magnetic field 147–578 mT
Cresci A et al. 2022 animal, lesser sandeel (<i>Ammodytes marinus</i>) (larvae) static magnetic field, underground cable, high-voltage direct current (HVDC) -
Durif CMF et al. 2023 animal, lumpfish (<i>Cyclopterus lumpus</i>) static magnetic field, DC, underground cable, high-voltage direct current (HVDC) -
Todorovic D et al. 2013 animal, mealworm beetle (<i>Tenebrio obscursus</i> and <i> Tenebrio molitor</i>), whole body static magnetic field, DC 50 mT
Yokoi S et al. 2003 animal, mouse signals/pulses, electric field, magnetic field, geomagnetic field -
Tsuji Y et al. 1996 animal, mouse/BALB/c CrSJc, whole body static magnetic field 4.88 T
Sándor K et al. 2007 animal, mouse/BALB/c and mouse/CFLP static magnetic field 1.47 T
Tian X et al. 2023 animal, mouse/BALB/c nu/nu (nude mouse) static magnetic field, also other exposures without EMF, co-exposure -
Zhou X et al. 2019 animal, mouse/C57BL static magnetic field, also other exposures without EMF, co-exposure -
Lv Y et al. 2022 animal, mouse/C57BL, whole body static magnetic field -
Ding HM et al. 2019 animal, mouse/C57BL/6 static magnetic field, shielding/field deprivation -
Khan MH et al. 2022 animal, mouse/C57BL/6 static magnetic field -
Lockwood DR et al. 2003 animal, mouse/C57BL/6, whole body static magnetic field, MRI 14.1 T
Hoyer C et al. 2012 animal, mouse/C57BL/6J static magnetic field, MRI 7 T
Tian L et al. 2022 animal, mouse/C57BL/6J static magnetic field, geomagnetic field, shielding/field deprivation -
Houpt TA et al. 2013 animal, mouse/C57BL/J, whole body static magnetic field 14.1 T
Cote JM et al. 2023 animal, mouse/C57BL6/J and 2 mutant strains (<i>het</i> and <i>tlt</i>) lacking proteins critical for otoconia genesis static magnetic field -
Nakhilnitskaya ZN et al. 1983 animal, mouse/C57Bl X CBA hybrid static magnetic field -
Davis HP et al. 1984 animal, mouse/CD-1 and mouse/LAF-1, whole body magnetic field, static magnetic field, 50/60 Hz, DC 1.65 mT–1.5 T
Choleris E et al. 2002 animal, mouse/CD-1, whole body magnetic field, static magnetic field, 50/60 Hz, electric field, shielding/field deprivation 0.07–52.06 µT
Prato FS et al. 2005 animal, mouse/CD-1, whole body magnetic field, geomagnetic field, low frequency, shielding/field deprivation 30 nT–55 µT
Kiss B et al. 2013 animal, mouse/CFLP static magnetic field 145–476.7 mT
Laszlo J et al. 2009 animal, mouse/CFLP, whole body static magnetic field 2–754 mT
Li Y et al. 2009 animal, mouse/Kunming, whole body geomagnetic field -
Nichols Jr TW 2012 animal, mouse/Ob/Ob static magnetic field -
Nakagawa M 1980 animal, mouse/ddY static magnetic field 20–30 mT
Putman NF et al. 2014 animal, rainbow trout (<i>Oncorhynchus mykiss</i>) geomagnetic field 42.68–444.6 µT
Jakubowska M et al. 2021 animal, rainbow trout (<i>Oncorhynchus mykiss</i>) (larvae) static magnetic field -
Laforge H et al. 1978 animal, rat static magnetic field -
Azizi E et al. 2022 animal, rat/ Wistar magnetic field, static magnetic field -
Mukhin VN et al. 2018 animal, rat/ Wistar geomagnetic field -
Bertolino G et al. 2013 animal, rat/ Wistar, partial body: head static magnetic field 320 mT
Giorgetto C et al. 2015 animal, rat/ Wistar, partial body: head static magnetic field, co-exposure 150–320 mT
High WB et al. 2000 animal, rat/Fischer 344, whole body static magnetic field 9.4 T
Thomas JR et al. 1986 animal, rat/Long-Evans Hooded, whole body magnetic field, static magnetic field, 50/60 Hz, DC, co-exposure 26–50 µT
Stern S et al. 1996 animal, rat/Long-Evans Hooded, whole body magnetic field, static magnetic field, 50/60 Hz, DC 26–88 µT
Innis NK et al. 1986 animal, rat/Long-Evans, whole body RF field, magnetic field, static magnetic field, MRI 147 mT
Creim JA et al. 1993 animal, rat/Long-Evans, whole body static magnetic field, DC, high-voltage direct current (HVDC) -
Kanai S et al. 2012 animal, rat/Sprague Dawley static magnetic field -
Wang T et al. 2022 animal, rat/Sprague Dawley static magnetic field -
Taniguchi N et al. 2004 animal, rat/Sprague Dawley, whole body static magnetic field -
Cason AM et al. 2006 animal, rat/Sprague-Dawley static magnetic field, MRI 14.1 T
Houpt TA et al. 2007 animal, rat/Sprague-Dawley static magnetic field, MRI 14.1 T
Houpt TA et al. 2007 animal, rat/Sprague-Dawley static magnetic field, MRI 0.05–14.1 T
Cason AM et al. 2009 animal, rat/Sprague-Dawley static magnetic field, DC, MRI 14.1 T
Houpt TA et al. 2010 animal, rat/Sprague-Dawley static magnetic field, MRI 14.1 T
Houpt TA et al. 2011 animal, rat/Sprague-Dawley static magnetic field, MRI 14.1 T
Houpt TA et al. 2011 animal, rat/Sprague-Dawley static magnetic field, DC, MRI 14.1 T
Nolte CM et al. 1998 animal, rat/Sprague-Dawley, whole body static magnetic field, DC 9.4 T
Creim JA et al. 2002 animal, rat/Sprague-Dawley, whole body magnetic field, static magnetic field, 50/60 Hz 26–50 µT