Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Wood AW et al. | 1998 | human, whole body | magnetic field, 50/60 Hz | 20 µT |
Burch JB et al. | 1999 | human, whole body | magnetic field, geomagnetic field, 50/60 Hz, occupational, co-exposure | 21.7 nT |
Akerstedt T et al. | 1999 | human, whole body | magnetic field, 50/60 Hz | 1 µT |
Burch JB et al. | 1999 | human, whole body | magnetic field, 50/60 Hz, occupational | 0.078–0.135 µT |
Graham C et al. | 2000 | human, whole body | magnetic field, 50/60 Hz | 28.3 µT |
Burch JB et al. | 2000 | human, whole body | magnetic field, 50/60 Hz, power transmission line, occupational | 0.36–1.05 µT |
Hong SC et al. | 2001 | human, whole body | magnetic field, 50/60 Hz, electric blanket | 700 nT–8.3 µT |
Graham C et al. | 2001 | human, whole body | magnetic field, 50/60 Hz | 28.3 µT |
Graham C et al. | 2001 | human, whole body | magnetic field, 50/60 Hz | 127.3 µT |
Davis S et al. | 2001 | human, whole body | magnetic field, 50/60 Hz, residential, co-exposure, also other exposures without EMF | 0.1 µT |
Graham C et al. | 2001 | human, whole body | magnetic field, 50/60 Hz | 28.3 µT |
Levallois P et al. | 2001 | human, whole body | electric field, magnetic field, 50/60 Hz, power transmission line, residential | 0.13–0.33 µT |
Youngstedt SD et al. | 2002 | human, whole body | magnetic field, 50/60 Hz, other domestic appliance, inhouse wiring, residential, co-exposure | 100 nT–6.31 µT |
Kurokawa Y et al. | 2003 | human, whole body | magnetic field, intermediate frequency, 50/60 Hz | 20–100 µT |
Touitou Y et al. | 2003 | human, whole body | magnetic field, 50/60 Hz, electrical substation, occupational, residential | 0.004–2.6 µT |
Ichinose TY et al. | 2004 | human, whole body | magnetic field, 50/60 Hz, occupational | 0.04–0.25 µT |
Cocco P et al. | 2005 | human, whole body | magnetic field, 50/60 Hz, other domestic appliance, low frequency, residential | 0.0045–0.148 µT |
Davis S et al. | 2006 | human, whole body | magnetic field, 50/60 Hz | 0.5–1 µT |
Noonan CW et al. | 2002 | human, whole body | magnetic field, 50/60 Hz, electrical substation, occupational | 0.06–0.3 µT |
Clark ML et al. | 2007 | human, whole body | Radio/TV transmitter, magnetic field, intermediate frequency, 50/60 Hz, residential | 20–130 nT |
Bellieni CV et al. | 2012 | human, whole body | magnetic field, 50/60 Hz, therapeutic/medical device | 0.45–8.84 µT |
Blackman CF et al. | 2001 | intact cell/cell culture, MCF-7 (human breast cancer cell line) | magnetic field, 50/60 Hz | 1.2 µT |
Rosen LA et al. | 1998 | intact cell/cell culture, rat pinealcytes | magnetic field, static magnetic field, 50/60 Hz, shielding/field deprivation | 70 nT–50 µT |
Tripp HM et al. | 2003 | isolated organ, pineal gland | magnetic field, 50/60 Hz | 500 µT |
Lewy H et al. | 2003 | isolated organ, pineal glands of rats/Wistar | magnetic field, 50/60 Hz, co-exposure | 1 mT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.