Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Rudolph K et al. | 1985 | animal, rat/Wistar-Füllinsdorf, whole body | magnetic field, 50/60 Hz | 40 µT |
Kavaliers M et al. | 1993 | animal, mouse/meadow vole (<i>Microtus pennsylvanicus</i>), whole body | magnetic field, 50/60 Hz | 100 µT |
Sienkiewicz ZJ et al. | 1998 | animal, mouse/C57BL/6J, whole body | magnetic field, 50/60 Hz | 7.5 µT–7.5 mT |
Kavaliers M et al. | 1985 | animal, mouse/CF-1 and mouse/C57BL, whole body | magnetic field, 50/60 Hz | 0–9 mT |
Prolic Z et al. | 2003 | invertebrate, beetle (<i>Morimus funereus</i>) | magnetic field, 50/60 Hz | 2 mT |
Jelenkovic A et al. | 2005 | animal, rat/Wistar | magnetic field, 50/60 Hz | 0.5 mT |
Prolic Z et al. | 2005 | animal, rat/Wistar | magnetic field, 50/60 Hz | 0.5 mT |
Manikonda PK et al. | 2007 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 50–100 µT |
Cui Y et al. | 2012 | animal, mouse/C57BL/6, whole body | magnetic field, 50/60 Hz | 0.1–1 mT |
Park WH et al. | 2012 | animal, mouse/ICR, whole body | magnetic field, 50/60 Hz | 2 mT |
Korpinar MA et al. | 2012 | animal, rat/Wistar albino, whole body | magnetic field, 50/60 Hz | 10 mT |
Sakhnini L et al. | 2012 | animal, mouse, whole body | magnetic field, 50/60 Hz | 1 mT |
Ryu JM et al. | 2009 | invertebrate, common cutworm larvae (<i>Spodoptera litura</i>) | magnetic field, 50/60 Hz | 1 mT |
Dimitrijevic D et al. | 2014 | invertebrate, <i>Drosophila subobscura</i> (larvae and just eclosed adults) | magnetic field, 50/60 Hz | 0.5 mT |
Salunke BP et al. | 2014 | animal, mouse/Swiss albino, whole body | magnetic field, 50/60 Hz | 1 mT |
Alsaeed I et al. | 2014 | animal, mouse/BALB/c, whole body | magnetic field, 50/60 Hz | 1 mT |
Chae KS | 2008 | invertebrate, common cutworm larvae (<i>Spodoptera litura</i>), whole body | magnetic field, 50/60 Hz | 0.2 mT |
Lai J et al. | 2016 | animal, rat/Sprague Dawley, whole body | magnetic field, 50/60 Hz | 100 µT |
Rostami A et al. | 2016 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 4 mT |
Bernal-Mondragón C et al. | 2016 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 1 mT |
Zmejkoski D et al. | 2017 | invertebrate, <i>Drosophila subobscura</i> (larvae and 1-day-old adults), whole body | magnetic field, 50/60 Hz | 0.5 mT |
Laszlo AM et al. | 2018 | - | magnetic field, 50/60 Hz | - |
Karimi SA et al. | 2019 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 1–2,000 µT |
Aydemir S et al. | 2016 | animal, rat/Sprague Dawley, whole body | magnetic field, 50/60 Hz | 0.21–2.7 µT |
Shepherd S et al. | 2019 | invertebrate, Honey bee (<i>Apis mellifera</i>), whole body | magnetic field, 50/60 Hz | 100–1,000 µT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.