Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Salford LG et al. | 1993 | animal, rat/Fischer 344 | permeability of the blood-brain barrier | 915 MHz | 0.33–3.3 W/kg | not specified | digital mobile phone, mobile communications, microwaves |
Masuda H et al. | 2007 | animal, rat/Sprague-Dawley, partial body: head | microcirculation in brain | 1,439 MHz | 0.6–4.8 W/kg | intermittent, 10 min on/20 min off, for 90 min | digital mobile phone, PDC, TDMA, mobile communications, mobile phone |
Masuda H et al. | 2007 | animal, rat/Sprague-Dawley, partial body: head | microcirculation in brain | 1,439 MHz | 0.64–2.4 W/kg | repeated daily exposure, 60 min/day, 5 days/week, for 4 weeks | digital mobile phone, PDC, TDMA, mobile communications, mobile phone |
Söderqvist F et al. | 2009 | human, partial body: head | integrity of blood-brain barrier and blood-cerebrospinal fluid barrier | 890 MHz | 1 W/kg | continuous for 30 min | mobile communications, digital mobile phone, GSM |
Franke H et al. | 2005 | model of blood-brain barrier (consisting of porcine brain microvascular endothelial cells) | permeability of the blood-brain barrier in a cell culture model | 1.966 GHz | 1.64 W/kg | continuous for 1 up to 3.5 days | UMTS, mobile communications |
Finnie JW et al. | 2001 | animal, mouse/C57BL/6NTac, whole body | blood-brain barrier permeability | 898.4 MHz | 4 W/kg | continuous for 60 min | GSM, mobile communications |
Finnie JW et al. | 2006 | animal, mouse/BALB/c, whole body | blood-brain barrier permeability | 900 MHz | 4 W/kg | repeated daily exposure for 60 min/day from day 1 to day 19 of gestation | GSM, mobile communications |
Finnie JW et al. | 2006 | animal, mouse/BALB/c, whole body | blood-brain barrier permeability | 900 MHz | 4 W/kg | repeated daily exposure, 60 min/day, for 7 days | digital mobile phone, GSM, mobile communications |
Finnie JW et al. | 2009 | animal, mouse, whole body | aquaporin-4 expression in the brain (as marker for blood-brain barrier permeability) | 900 MHz | 4 W/kg | continuous for 60 min | mobile phone, GSM, mobile communications, PW pulsed wave |
Tang J et al. | 2015 | animal, rat/Sprague-Dawley, partial body: head | relationship between memory function, blood brain barrier permeability and the mkp-1/ERK pathway in the rat brain | 900 MHz | 0.016–2 W/g | continuous for 3 h/day for 14 days | mobile phone, mobile communications |