Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Scarfi MR et al. | 1991 | intact cell/cell culture, human peripheral blood | magnetic field, signals/pulses, 50/60 Hz | 2.5 mT |
Scarfi MR et al. | 1994 | intact cell/cell culture, human peripheral blood lymphocytes | magnetic field, signals/pulses, 50/60 Hz | 2.5 mT |
Cossarizza A et al. | 1993 | intact cell/cell culture, human peripheral blood mononuclear cells | electric field, magnetic field, signals/pulses, 50/60 Hz | 2.5 mT |
Suri A et al. | 1996 | intact cell/cell culture, embryonic fibroblast cell line (rat) | magnetic field, 50/60 Hz, co-exposure | 3 mT |
Villarini M et al. | 2006 | intact cell/cell culture | magnetic field, 50/60 Hz, co-exposure | 3 mT |
Kim J et al. | 2010 | intact cell/cell culture, HeLa cell line (human adenocarcinoma cell line) and IMR90 (human lung fibroblasts) | magnetic field, 50/60 Hz | 3–6 mT |
Antonopoulos A et al. | 1995 | intact cell/cell culture, human peripheral blood | magnetic field, 50/60 Hz | 5 mT |
Miyakoshi J et al. | 1999 | intact cell/cell culture, CHO-K1 (Chinese hamster ovary K1) cells | magnetic field, 50/60 Hz, co-exposure | 5 mT |
Fairbairn DW et al. | 1994 | intact cell/cell culture, HL-60 cells (human acute myeloid leukaemia cell line), Raji cells (human Burkitt lymphoma cells), HeLa cell line (human adenocarcinoma cell line), and human peripheral blood leukocytes | magnetic field, 50/60 Hz | 5 mT |
Ding GR et al. | 2003 | intact cell/cell culture, CHO-K1 (Chinese hamster ovary K1) cells | magnetic field, 50/60 Hz, also other exposures without EMF, co-exposure | 5 mT |
Pasquini R et al. | 2003 | intact cell/cell culture, Jurkat cells (human lymphoblastoid T cells) | magnetic field, 50/60 Hz, co-exposure | 5 mT |
Koyama S et al. | 2004 | plasmid | magnetic field, 50/60 Hz, co-exposure | 5 mT |
Koyama S et al. | 2005 | DNA/RNA, plasmid | magnetic field, 50/60 Hz, co-exposure | 5 mT |
Koyama S et al. | 2008 | intact cell/cell culture, A172 (human glioblastoma cells) | magnetic field, 50/60 Hz, co-exposure | 5 mT |
Mizuno K et al. | 2014 | intact cell/cell culture, W138VA13 (human embryo lung-derived cells) and XP2OS(SV) (human xeroderma pigmentosum skin-derived cells) | magnetic field, 50/60 Hz, co-exposure | 5 mT |
Kheiry EV et al. | 2019 | animal, mouse/BALB/c | magnetic field, 50/60 Hz, also other exposures without EMF, co-exposure | 5 mT |
Yaguchi H et al. | 1999 | intact cell/cell culture, mouse m5S cells | magnetic field, 50/60 Hz, co-exposure | 5–400 mT |
Miyakoshi J et al. | 2000 | intact cell/cell culture, MO54 cells (derived from a human malignant glioma) | magnetic field, 50/60 Hz, co-exposure | 5–400 mT |
Yaguchi H et al. | 2000 | intact cell/cell culture, mouse m5S cells | magnetic field, 50/60 Hz, power transmission line, co-exposure | 5–400 mT |
Zmyslony M et al. | 2000 | intact cell/cell culture, rat lymphocytes | magnetic field, static magnetic field, 50/60 Hz | 7 mT |
Jajte J et al. | 2001 | intact cell/cell culture, rat lymphocytes | magnetic field, 50/60 Hz | 7 mT |
Miyakoshi Y et al. | 2012 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz, co-exposure | 10 mT |
El-Bialy NS et al. | 2013 | animal, mouse/BALB, whole body | magnetic field, 50/60 Hz, co-exposure | 10 mT |
Nakasono S et al. | 2000 | bacterium, <i>Salmonella typhimurium</i> (TA98, TA100, TA1535, TA1537), <i>Escherichia coli</i> (WP2 <i>uvrA</i>, WP2 <i>uvrA</i>/pKM101) | magnetic field, 50/60 Hz, co-exposure | 14 mT |
Williams PA et al. | 2006 | bacterium, <i>Salmonella typhimurium</i>/LT2 (TT22240; TT24257; TT24470) | magnetic field, 50/60 Hz, inhouse wiring, other domestic appliance | 14.6 mT |