Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Feng B et al. | 2016 | intact cell/cell culture, human amniotic cells | magnetic field, 50/60 Hz | 0.2–2 mT |
Kabuto H et al. | 2001 | mouse brain homogenates or phosphatidylcholine solution | magnetic field, static magnetic field, low frequency, 50/60 Hz, co-exposure, also other exposures without EMF | 0.2–300 mT |
Amaroli A et al. | 2013 | intact cell/cell culture, slime mold <i>Dictyostelium discoideum</i> | magnetic field, 50/60 Hz | 300 µT |
Jelenkovic A et al. | 2005 | animal, rat/Wistar | magnetic field, 50/60 Hz | 0.5 mT |
Jelenkovic A et al. | 2006 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 0.5 mT |
Rageh MM et al. | 2012 | animal, rat/Wistar, whole body | magnetic field, low frequency, 50/60 Hz | 0.5 mT |
Duan W et al. | 2014 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 500 µT |
Raus Balind S et al. | 2014 | animal, mongolian gerbils <i>(Meriones unguiculatus)</i>, whole body | magnetic field, 50/60 Hz | 0.5 mT |
Seifirad S et al. | 2014 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 0.5 mT |
Hu Y et al. | 2016 | animal, mouse/3xTg and 129/C57BL/6, whole body | magnetic field, 50/60 Hz | 500 µT |
Nakayama M et al. | 2016 | intact cell/cell culture, macrophages (RAW 246) | magnetic field, 50/60 Hz, co-exposure | 500 µT |
Rahmani S et al. | 2021 | blood samples | 50/60 Hz, magnetic field | 0.5–1 mT |
Lewicka M et al. | 2015 | intact cell/cell culture, human blood platelets | electric field, magnetic field, 50/60 Hz, PC/TV monitor, therapeutic/medical device | 0.5–10 mT |
Jimena I et al. | 2009 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz, co-exposure | 0.7 mT |
Tasset I et al. | 2012 | animal, rat/Wistar, partial body: head | magnetic field, 50/60 Hz, TMS (transcranial stimulation), co-exposure | 0.7 mT |
Kim SJ et al. | 2017 | intact cell/cell culture, mouse/macrophage cell line RAW 264.7 | magnetic field, 50/60 Hz, low frequency, co-exposure | 0.8 mT |
Rollwitz J et al. | 2004 | intact cell/cell culture | magnetic field, 50/60 Hz | 1 mT |
Lupke M et al. | 2004 | intact cell/cell culture, human umbilical cord blood-derived monocytes and human Mono Mac 6 cells (human acute monocytic leukemia cell line) | magnetic field, 50/60 Hz | 1 mT |
Palumbo R et al. | 2006 | intact cell/cell culture, Jurkat cells (T lymphocyte hybridoma cell line) | magnetic field, 50/60 Hz, power transmission line, co-exposure | 1 mT |
Falone S et al. | 2007 | intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) | magnetic field, 50/60 Hz | 1 mT |
Erdal N et al. | 2008 | animal, rat/Wistar albino, whole body | magnetic field, 50/60 Hz | 1 mT |
Eleuteri AM et al. | 2009 | intact cell/cell culture, Caco 2 cells (human colon adenocarcinoma cell line) | magnetic field, low frequency, 50/60 Hz, power transmission line | 1 mT |
Frahm J et al. | 2010 | intact cell/cell culture, murine bone marrow-derived macrophages | magnetic field, low frequency, 50/60 Hz | 1 mT |
Garip AI et al. | 2010 | intact cell/cell culture, K562 cells (human erythroleukemic cell line) | magnetic field, low frequency, 50/60 Hz | 1 mT |
Mariucci G et al. | 2010 | animal, mouse/CD-1, whole body | magnetic field, 50/60 Hz | 1 mT |