Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Hirose H et al. | 2007 | intact cell/cell culture, A172 (human glioblastoma cells) and IMR90 fibroblasts (from fetal lungs) | cellular stress response (Hsp27 (heat-shock protein 27) content and hsp27 phosphorylation) | 2.1425 GHz | 80–800 mW/kg | continuous for 2, 24, or 48 h for A172 cells | mobile phone base station, CDMA, mobile communications, microwaves |
Bodera P et al. | 2015 | animal, rat/Wistar, whole body | lipid peroxidation in brain, blood, liver and kidney | 1,800 MHz | 0.024–0.028 W/kg | continuous for 15 minutes/day for 5 days | mobile phone base station, GSM, TDMA, mobile communications, co-exposure |
Yurekli AI et al. | 2006 | animal, rat/Wistar albino, whole body | oxidative stress | 945 MHz | 11.3 mW/kg | repeated daily exposure, 7 h/day, for 8 days | mobile phone base station, GSM, mobile communications |
Hässig M et al. | 2014 | animal, cow/Simmental and Brown Swiss, whole body | oxidative stress in the blood of cattle | 900 MHz | - | intermittent exposure for min. 6 h 36 min, max. 19 h and 16 h 43 min on average per day with a standard deviation of 3 h 03 min for 30 days | mobile phone base station, GSM, mobile communications, PW pulsed wave |
Jelodar G et al. | 2013 | animal, rat/Sprague-Dawley, whole body | oxidative stress in the eye | 900 MHz | - | continuous for 4 h/day on 45 days | mobile phone base station, mobile communications |
Jelodar G et al. | 2013 | animal, rat/Sprague-Dawley, whole body | oxidative stress in the testes | 900 MHz | - | continuous for 4 h/day for 45 days | mobile phone base station, mobile communications |
Marzook EM et al. | 2014 | animal, rat/albino | oxidative stress and other parameters in the blood | 900 MHz | - | continuous for 24 h/day for 8 weeks | mobile phone base station, mobile communications, co-exposure |
Akbari A et al. | 2014 | animal, rat/Sprague-Dawley, whole body | oxidative stress in the rat brain | 900 MHz | - | continuous for 4 h/day for 45 days | mobile phone base station, mobile communications, co-exposure |
Hong MN et al. | 2012 | intact cell/cell culture, MCF10 A cells (human breast epithelial cells) | oxidative stress | 837 MHz | 2–4 W/kg | continuous for 2 h | mobile phone, CDMA, W-CDMA, mobile communications |
Lee JS et al. | 2016 | intact cell/cell culture, HT22 (mouse hippocampus neuronal cells) | cytotoxicity | 837–1,950 MHz | 2 W/kg | continuous for 2 hours | mobile phone, CDMA, W-CDMA, mobile communications, also other exposures without EMF, co-exposure |