Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Salek F et al. | 2021 | intact cell/cell culture | magnetic field, 50/60 Hz, co-exposure, also other exposures without EMF | 2.5 mT |
Strasak L et al. | 2002 | bacterium, <i>Escherichia coli</i> | magnetic field, 50/60 Hz | 2.7–10 mT |
Fojt L et al. | 2004 | bacterium, <i>Escherichia coli</i>, <i>Leclercia adecarboxylata</i>, <i>Staphylococcus aureus</i> | magnetic field, low frequency, 50/60 Hz | 2.7–10 mT |
Del Giudice E et al. | 2007 | intact cell/cell culture, human neuroglioma cell line (H4; cells transfected with the human amyloid precursor protein (APP)) | magnetic field, 50/60 Hz | 3.1 mT |
Cios A et al. | 2021 | intact cell/cell culture, HEK293 (kidney cells), 786-O, 769-P, and Caki1 (clear cell renal carcinoma cell lines) | magnetic field, 50/60 Hz | 4.5 mT |
Sakurai T et al. | 2008 | intact cell/cell culture, HIT-T15 cells (hamster-derived insulin-secreting cell line) | magnetic field, low frequency, 50/60 Hz | 5 mT |
Akbarnejad Z et al. | 2017 | intact cell/cell culture, U87 (human glioblastoma cell line) | magnetic field, signals/pulses, 50/60 Hz | 5–10 mT |
Kakikawa M et al. | 2012 | bacterium, <i>Escherichia coli</i>/W3110 | magnetic field, 50/60 Hz, co-exposure | 5–50 mT |
Miyakoshi J et al. | 2000 | intact cell/cell culture, MO54 cells (derived from a human malignant glioma) | magnetic field, 50/60 Hz, co-exposure | 5–400 mT |
Yaguchi H et al. | 2000 | intact cell/cell culture, mouse m5S cells | magnetic field, 50/60 Hz, power transmission line, co-exposure | 5–400 mT |
Novak J et al. | 2007 | intact cell/cell culture, yeast (<i>Saccharomyces cerevisiae</i>) | magnetic field, 50/60 Hz | 5.2–10 mT |
Jedrzejczak-Silicka M et al. | 2021 | intact cell/cell culture, L929 cells (murine fibroblast cells) and HaCaT cells (human keratinocytes cell line) | magnetic field, 50/60 Hz, low frequency | 5.9–28.4 mT |
Dehghani-Soltani S et al. | 2021 | intact cell/cell culture, A172 (human glioblastoma cells) and T98 cell line | magnetic field, 50/60 Hz, signals/pulses, co-exposure, also other exposures without EMF | 7 mT |
Yin C et al. | 2016 | intact cell/cell culture, primary hippocampal neurons from newborn Sprague-Dawley rats | magnetic field, 50/60 Hz, co-exposure | 8 mT |
Fojt L et al. | 2007 | bacterium, <i>Paracoccus denitrificans</i>/CCM 982 | magnetic field, 50/60 Hz | 10 mT |
Urnukhsaikhan E et al. | 2016 | intact cell/cell culture, human bone marrow-derived mesenchymal stem cells (hBM-MSCs) | magnetic field, signals/pulses, 50/60 Hz | 10 mT |
Lim HM et al. | 2021 | intact cell/cell culture, human dental pulp stem cells | magnetic field, signals/pulses, low frequency, 50/60 Hz | 10 mT |
Baharara J et al. | 2016 | intact cell/cell culture, A2780 cells (cisplatin-resistant human ovarian adenocarcinoma cells) | magnetic field, 50/60 Hz, co-exposure | 20 mT |
Kula B et al. | 1996 | intact cell/cell culture, fibroblasts | magnetic field, static magnetic field, low frequency, 50/60 Hz | 20–490 mT |
Fijalkowski K et al. | 2015 | bacterium, <i>Staphylococcus aureus, Escherichia coli, Acinetobacter baumannii, Pseudomonas aeruginosa, Serratia marcescens, Streptococcus mutans, Cronobacter sakazaki, Klebsiella oxytoca, Staphylococcus xylosus</i> | magnetic field, low frequency, 50/60 Hz | 25–34 mT |
Nawrotek P et al. | 2014 | bacterium, <i>Escherichia coli</i>/O157:H7 and E68II/0141 and <i>Staphylococcus aureus</i>/FRI 913, ATCC 25923 and ATCC 43300 | magnetic field, 50/60 Hz | 30 mT |
Kakikawa M et al. | 2014 | intact cell/cell culture, bacterium, <i>E. coli</i>/JE5595 | magnetic field, 50/60 Hz, co-exposure | 50 mT |
Colciago A et al. | 2021 | intact cell/cell culture, HEI-193 cells (human vestibular schwannoma cell line derived from a NF2 patient) | 50/60 Hz, magnetic field | 0.1 T |
Miyakoshi J et al. | 1994 | intact cell/cell culture, human leukemia cell lines (HL60RG, CCRF-CEM9), GM0637 cells (normal human fibroblast cell line), TAT2SF cells (human Louis-Bar syndrome fibroblast cell line) | magnetic field, 50/60 Hz, also other exposures without EMF | 400 mT |
Miyakoshi J et al. | 1997 | intact cell/cell culture, MeWo cells (malignant melanoma cells) | magnetic field, 50/60 Hz, also other exposures without EMF | 400–500 mT |