Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Craviso GL et al. | 2003 | intact cell/cell culture, bovine adrenal medullary chromaffin cells | 50/60 Hz, magnetic field | 10 µT–2 mT |
Yang X et al. | 2019 | intact cell/cell culture, FL cells (human amniotic cells) | 50/60 Hz, magnetic field | 0.4 mT |
Martínez MA et al. | 2019 | intact cell/cell culture, NB69 cells (human neuroblastoma cells) | 50/60 Hz, magnetic field | 100 µT |
Özgün A et al. | 2021 | intact cell/cell culture, bone marrow-derived mesenchymal stem cells (BM-MSCs) | 50/60 Hz, magnetic field | 1 mT |
Lin KW et al. | 2016 | intact cell/cell culture, yeast (<i>Saccharomyces cerevisiae</i>)/SB34 | RF field, microwaves, electric field, magnetic field, 50/60 Hz | 6 mT |
Schimmelpfeng J et al. | 1993 | intact cell/cell culture, SV40-swiss-3T3 cells (mouse fibroblast cell line) | electric field, magnetic field, 50/60 Hz | 2 mT |
Xiao-Feng P et al. | 2005 | animal, rat/Wistar, whole body | electric field, magnetic field, 50/60 Hz, power transmission line | 9 µT |
Schimmelpfeng J et al. | 1997 | intact cell/cell culture, SV40-swiss-3T3 cells (mouse fibroblast cell line) | magnetic field, 50/60 Hz | 16 mT |
Lindstrom E et al. | 1998 | intact cell/cell culture, Jurkat cells (T-lymphocyte hybridoma cell line; clone E6-1 wild type and four derivative clones) | magnetic field, 50/60 Hz | 100–150 µT |
Korzh-Sleptsova IL et al. | 1995 | intact cell/cell culture, Jurkat cells (human lymphoblastoid T cells) | magnetic field, 50/60 Hz | 100–150 µT |
Schimmelpfeng J et al. | 1995 | intact cell/cell culture, SV40-swiss-3T3 cells (mouse fibroblast cell line) | magnetic field, 50/60 Hz | 2 mT |
Verdugo-Diaz L et al. | 1998 | intact cell/cell culture, chromaffin cells (from neonatal Wistar rats) | magnetic field, 50/60 Hz | 700 µT |
Lai H et al. | 1999 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 50 µT–2 mT |
Santoro N et al. | 1997 | intact cell/cell culture, Raji cells (human Burkitt lymphoma B lymphocyte cell line) | magnetic field, 50/60 Hz | 2 mT |
Dibirdik I et al. | 1998 | intact cell/cell culture, DT40 (chicken lymphoma B-cells) (wild-type, LYN-deficient, SYK-deficient, PLC-gamma2-deficient clones) | magnetic field, 50/60 Hz | 100 µT |
Lin H et al. | 1998 | intact cell/cell culture, HL-60 (human promyelocytic leukemia cells), MCF-7, T-47D, and HTB-124 cell lines (human breast cancer cell lines) | magnetic field, 50/60 Hz | 8 µT |
Zhang L et al. | 1997 | intact cell/cell culture, chromaffin cells (from rat adrenal medulla) | magnetic field, 50/60 Hz | 1 mT |
Jin M et al. | 2000 | intact cell/cell culture, INITC3H 10T1/2 cells (derived from mouse embryo fibroblasts, transformed carcinogenically by methylcholanthrene, resulting neoplastic phenotype can be suppressed by the presence of retinyl acetate) | magnetic field, 50/60 Hz | 300 µT |
Ishido M et al. | 2001 | intact cell/cell culture, MCF-7 cells (human breast cancer cell line) | magnetic field, 50/60 Hz | 1.2–100 µT |
Zhou J et al. | 2002 | intact cell/cell culture, HL-60 (human acute myeloid leukaemia cells) | magnetic field, 50/60 Hz | 0.1 mT |
Zeng QL et al. | 2003 | intact cell/cell culture, CHL (Chinese hamster lung) cells | magnetic field, 50/60 Hz | 0.8 mT |
Verdugo-Diaz L et al. | 2002 | intact cell/cell culture, chromaffin cells (from neonatal rats) | magnetic field, 50/60 Hz | 700 µT |
Malagoli D et al. | 2003 | invertebrate, mussel/<i>Mytilus galloprovincialis</i>, whole body | magnetic field, 50/60 Hz | 300–600 µT |
Sun WJ et al. | 2002 | intact cell/cell culture, CHL (Chinese hamster lung) cells | magnetic field, 50/60 Hz | 400–800 µT |
Ikehara T et al. | 2003 | intact cell/cell culture, HeLa cell line (human adenocarcinoma cell line) | magnetic field, 50/60 Hz | 43.6 mT |
Zeng Q et al. | 2006 | intact cell/cell culture, NIH3T3 cells (mouse fibroblasts) | magnetic field, 50/60 Hz | 0.2–0.4 mT |
Ventura C et al. | 2005 | intact cell/cell culture, GTR1 cells (derivative of R1 embryonic stem cells) | magnetic field, 50/60 Hz | 0.8 mT |
Lupke M et al. | 2006 | intact cell/cell culture, human umbilical cord blood-derived monocytes | magnetic field, 50/60 Hz | 1 mT |
Jia C et al. | 2007 | isolated bio./chem. substance, intact cell/cell culture, purified EGFR, CHL (Chinese hamster lung) cells | magnetic field, 50/60 Hz | 0.4 mT |
Li CM et al. | 1999 | intact cell/cell culture, CHL (Chinese hamster lung) cells | magnetic field, 50/60 Hz | 0.05–1.6 mT |
Ke XQ et al. | 2008 | intact cell/cell culture, CHL (Chinese hamster lung) cells | magnetic field, 50/60 Hz | 0.4 mT |
Sun WJ et al. | 2001 | intact cell/cell culture, CHL (Chinese hamster lung) cells | magnetic field, 50/60 Hz | 0.4–0.8 mT |
Girgert R et al. | 2010 | intact cell/cell culture, MCF-7 (breast cancer cell line, parental cells and cells transfected with the MT1 gene (for the membrane-bound melatonin receptor)) | magnetic field, 50/60 Hz | 1.2 µT |
Calvo AC et al. | 1999 | intact cell/cell culture, snail neurons (<i>Helix aspersa</i>) | magnetic field, 50/60 Hz | 1–15 mT |
Azanza MJ et al. | 1998 | intact cell/cell culture, snail neurons (<i>Helix aspersa</i>) | magnetic field, 50/60 Hz | 1–15 mT |
He YL et al. | 2013 | intact cell/cell culture, granule cells | magnetic field, 50/60 Hz | 0.4–1 mT |
Park JE et al. | 2013 | intact cell/cell culture, human bone marrow-derived mesenchymal stem cells (hBM-MSCs) | magnetic field, 50/60 Hz | 1 mT |
Azanza MJ et al. | 2013 | isolated organ, snail neurons (<i>Helix aspersa</i>) | magnetic field, 50/60 Hz | 0.02–15 mT |
Cui Y et al. | 2014 | intact cell/cell culture, HEK 293 cells (human embryonic kidney cell line) and cortical neurons (cultured from embryonic ICR mice) | magnetic field, 50/60 Hz | 200 µT |
Wu X et al. | 2014 | intact cell/cell culture, FL cells (human amniotic cells) | magnetic field, 50/60 Hz | 0.4 mT |
Luo FL et al. | 2014 | intact cell/cell culture, neurons from the entorhinal cortex of newborn rats | magnetic field, 50/60 Hz | 1–3 mT |
Chen Y et al. | 2014 | intact cell/cell culture, mouse embryonic fibroblasts | magnetic field, 50/60 Hz | 2 mT |
Liu Y et al. | 2015 | intact cell/cell culture, GC-2 cells (murine spermatocyte-derived cell line) | magnetic field, 50/60 Hz | 1–3 mT |
Feng B et al. | 2016 | intact cell/cell culture, human amniotic epithelial cells | magnetic field, 50/60 Hz | 4 mT |
Sun ZC et al. | 2016 | animal, mouse/C57, whole body | magnetic field, 50/60 Hz | 1 mT |
Qiu L et al. | 2016 | intact cell/cell culture, human amniotic (FL) cells | magnetic field, 50/60 Hz | 0.4 mT |
Wang Y et al. | 2016 | intact cell/cell culture, FL cells (human amniotic cells) | magnetic field, 50/60 Hz | 0.4 mT |
Ma Q et al. | 2016 | intact cell/cell culture, embryonic neural stem cells (mouse/BALB/c) | magnetic field, 50/60 Hz | 1 mT |
Feng B et al. | 2016 | intact cell/cell culture, human amniotic cells | magnetic field, 50/60 Hz | 0.2–2 mT |
Feng B et al. | 2016 | intact cell/cell culture, human amniotic epithelial cells (FL) | magnetic field, 50/60 Hz | 0.1–0.4 mT |