Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on magnetic power frequency fields (50/60 Hz)

2045 studies in total
  1. 764 studies
  2. 633 studies
  3. 511 studies
  4. 414 studies
  5. 329 studies
  6. 207 studies

DNA, proteins, and oxidative stress

633 studies in total
  1. 255 studies
  2. 211 studies
  3. 182 studies
  4. 47 studies

Genotoxicity 211 studies in total

Authors Year Exposed system Parameters Magnetic flux density/field strength
Kim J et al. 2012 intact cell/cell culture, HeLa cell line (human adenocarcinoma cell line) and IMR90 (human lung fibroblasts) magnetic field, low frequency, 50/60 Hz 2–14 mT
Focke F et al. 2010 intact cell/cell culture, HeLa cell line (human adenocarcinoma cell line), MRC-5 (human primary fetal lung fibroblasts), and human primary fibroblasts low frequency, 50/60 Hz, power transmission line, magnetic field 1 mT
Pasquini R et al. 2003 intact cell/cell culture, Jurkat cells (human lymphoblastoid T cells) magnetic field, 50/60 Hz, co-exposure 5 mT
Manser M et al. 2017 intact cell/cell culture, Jurkat cells (human lymphoblastoid T cells), hematopoietic stem cells (CD34+ cells derived from umbilical cord blood) magnetic field, 50/60 Hz 1 mT
Moretti M et al. 2005 intact cell/cell culture, Jürkat cells (human lymphoblastoid T cells) magnetic field, 50/60 Hz, co-exposure 1 mT
Jin H et al. 2015 intact cell/cell culture, L123 cells (human lung epithelial cells) magnetic field, 50/60 Hz, co-exposure 1–2 mT
Nieminen V et al. 2022 intact cell/cell culture, MCF-7 (human breast cancer cell line) static magnetic field, magnetic field, 50/60 Hz, co-exposure, also other exposures without EMF -
Dees C et al. 1996 intact cell/cell culture, MCF-7 and T-47D cell lines (human breast cancer cell lines) magnetic field, 50/60 Hz, co-exposure 1.2–900 µT
Crocetti S et al. 2013 intact cell/cell culture, MCF-7 cells (human breast cancer cell line) and MCF-10 cells (human non-tumorigenic breast epithelial cell line) and C2C12 cells (mouse myoblast cell line) magnetic field, low frequency, signals/pulses, 50/60 Hz 2–5 mT
Miyakoshi J et al. 2000 intact cell/cell culture, MO54 cells (derived from a human malignant glioma) magnetic field, 50/60 Hz, co-exposure 5–400 mT
Miyakoshi J et al. 1997 intact cell/cell culture, MeWo cells (malignant melanoma cells) magnetic field, 50/60 Hz, also other exposures without EMF 400–500 mT
Miyakoshi J et al. 1996 intact cell/cell culture, MeWo cells (malignant melanoma cells) magnetic field, 50/60 Hz, co-exposure 400 mT
Jin YB et al. 2014 intact cell/cell culture, NIH3T3 cells (mouse fibroblast cell line), WI-38 cells (human lung fibroblast cells), L-132 (human embryonic lung tissue), MCF10A cells (human breast epithelial cells); partially transfected with a c-Myc or empty vector magnetic field, 50/60 Hz, co-exposure 1 mT
Jin YB et al. 2012 intact cell/cell culture, NIH3T3 cells (mouse fibroblasts) and WI38 cells (human lung fibroblasts), normal and transfected with a c-Myc-containing vector or with an empty vetor magnetic field, low frequency, 50/60 Hz, co-exposure 0.01–1 mT
Luukkonen J et al. 2011 intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) magnetic field, low frequency, 50/60 Hz, co-exposure 100 µT
Luukkonen J et al. 2014 intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) magnetic field, 50/60 Hz, co-exposure 100 µT
Kesari KK et al. 2015 intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) magnetic field, 50/60 Hz, co-exposure 100 µT
Benassi B et al. 2019 intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) 50/60 Hz, magnetic field, co-exposure 1 mT
Mustafa E et al. 2022 intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) 50/60 Hz, magnetic field -
Villarini M et al. 2017 intact cell/cell culture, SH-SY5Y and SK-N-BE-2 (human neuroblastoma cell lines) magnetic field, 50/60 Hz, co-exposure, also other exposures without EMF 0.01–1 mT
Kesari KK et al. 2016 intact cell/cell culture, SH-SY5Y cells (human neuroblastoma cell line) and C6 (rat glioma cell line) magnetic field, 50/60 Hz 10–30 µT
Simko M et al. 2001 intact cell/cell culture, SHE (syrian hamster embryo) cells magnetic field, 50/60 Hz, co-exposure 1 mT
Miyakoshi J et al. 1998 intact cell/cell culture, Saos-LP-12 (cell line derived from human osteosarcoma) magnetic field, 50/60 Hz 400 mT
Nguyen H et al. 2023 intact cell/cell culture, TK6 cells (lymphoblastoma cells) magnetic field, 50/60 Hz -
Su L et al. 2017 intact cell/cell culture, U251 and A127 (human glioblastoma cell lines), SH-SY5Y (human neuroblastoma cell line), rat astrocytes, rat microglia, primary cortical neurons (of rat) magnetic field, low frequency, 50/60 Hz 2 mT