Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Bardasano JL et al. | 1985 | animal, homing pigeon (<i>Columba livia</i>) | magnetic field, 50/60 Hz | 20 µT |
Burchard JF et al. | 1998 | animal, cow/Holstein, whole body | electric field, magnetic field, 50/60 Hz | 30 µT |
Singh M et al. | 2002 | drinking water of the rats | magnetic field, 50/60 Hz | 36.2–51.2 µT |
Jadidi M et al. | 2016 | intact cell/cell culture, rat bone marrow-derived mesenchymal stem cells | magnetic field, 50/60 Hz | 40–400 µT |
Manikonda PK et al. | 2007 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 50–100 µT |
Ossenkopp KP et al. | 1991 | animal, rat/Long-Evans Hooded, whole body | magnetic field, 50/60 Hz, co-exposure | 50–185 µT |
Lukac T et al. | 2006 | animal, rat/Mill Hill, whole body | electric field, magnetic field, 50/60 Hz | 50–500 µT |
Fadakar K et al. | 2013 | animal, mouse, whole body | magnetic field, 50/60 Hz | 100 µT |
Zhang C et al. | 2013 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz, co-exposure | 100 µT |
Zhang Y et al. | 2015 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 100 µT |
Selmaoui B et al. | 1999 | animal, rat/Wistar | magnetic field, low frequency, 50/60 Hz | 100 µT |
Saha S et al. | 2014 | animal, mouse/C57BL/6, whole body: <i>in utero</i> | magnetic field, 50/60 Hz, also other exposures without EMF | 100–300 µT |
Lai H et al. | 1997 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 100 µT–0.5 mT |
Akdag MZ et al. | 2013 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 100–500 µT |
Masoudian N et al. | 2015 | organelle/cell part, synaptosomes | magnetic field, 50/60 Hz | 0.1–2 mT |
Samiee F et al. | 2017 | animal, carp (<i>Cyprinus carpio</i>), whole body | magnetic field, 50/60 Hz | 0.1–7 mT |
Kavaliers M et al. | 1998 | animal, mouse/CF-1, whole body | magnetic field, 50/60 Hz, co-exposure | 141 µT |
Keskil IS et al. | 2001 | animal, mouse, whole body | magnetic field, 50/60 Hz | 200 µT |
Canseven AG et al. | 2007 | animal, mouse/Swiss albino, whole body | magnetic field, 50/60 Hz, co-exposure | 0.2 mT |
Varro P et al. | 2009 | tissue slices, brain, rat/Wistar, animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 250–500 µT |
Woodbine L et al. | 2015 | animal, mouse/C57BL/6 (embryo), whole body | magnetic field, 50/60 Hz, co-exposure | 300 µT |
Shin EJ et al. | 2007 | animal, mouse/ICR | magnetic field, low frequency, 50/60 Hz | 0.3–2.4 mT |
Shin EJ et al. | 2011 | animal, mouse/C57BL/6, whole body | magnetic field, 50/60 Hz, co-exposure | 0.3–2.4 mT |
Liu X et al. | 2015 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 380–420 µT |
Zhao QR et al. | 2015 | animal, mouse/ICR, whole body | magnetic field, 50/60 Hz | 0.4–1 mT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.