Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Krueger WF et al. | 1975 | animal, chicken | RF field, UHF fields, CW continuous wave, microwaves, magnetic field, electric field, 50/60 Hz | 0.1–0.2 mT |
Krueger WF et al. | 1972 | animal, young chicken, whole body | TV broadcast (VHF/UHF), electric field, magnetic field, 50/60 Hz | - |
Kumar S et al. | 2013 | animal, rat/ Wistar, whole body | magnetic field, 50/60 Hz, therapeutic/medical device | 17.96 µT |
Kumar S et al. | 2021 | animal, rat/Wistar | magnetic field, 50/60 Hz, low frequency | 17.96 µT |
Lai H | 1996 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz, co-exposure | 750 µT |
Lai H et al. | 1998 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 1 mT |
Lai J et al. | 2016 | animal, rat/Sprague Dawley, whole body | magnetic field, 50/60 Hz | 100 µT |
Laszlo AM et al. | 2018 | - | magnetic field, 50/60 Hz | - |
Lei Y et al. | 2005 | animal, rat/Sprague-Dawley, whole body | magnetic field, low frequency, 50/60 Hz | 1.8–2.2 mT |
Liu T et al. | 2008 | animal, rat/Sprague-Dawley, whole body | magnetic field, low frequency, 50/60 Hz | 2 mT |
Liu Z et al. | 2019 | animal, rat/Sprague-Dawley, whole body | 50/60 Hz, magnetic field | 30–500 µT |
Lovely RH et al. | 1992 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 3.03 mT |
Manikonda PK et al. | 2007 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 50–100 µT |
McKay BE et al. | 2003 | animal, rat/Wistar, whole body | 50/60 Hz, magnetic field | 1.5–200 µT |
Migdał P et al. | 2022 | invertebrate, honey bee (<i>Apis mellifera carnica</i>) | magnetic field, 50/60 Hz, power transmission line | - |
Orr JL et al. | 1995 | animal, monkey/yellow baboon (<i>Papio cynocephalus</i>), whole body | electric field, magnetic field, 50/60 Hz | 50–100 µT |
Park WH et al. | 2012 | animal, mouse/ICR, whole body | magnetic field, 50/60 Hz | 2 mT |
Pesic V et al. | 2004 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz, co-exposure | 6 mT |
Prato FS et al. | 1997 | invertebrate, land snail (<i>Cepaea nemoralis</i>) | magnetic field, static magnetic field, low frequency, 50/60 Hz | 39.1–282 µT |
Prolic Z et al. | 2003 | invertebrate, beetle (<i>Morimus funereus</i>) | magnetic field, 50/60 Hz | 2 mT |
Prolic Z et al. | 2005 | animal, rat/Wistar | magnetic field, 50/60 Hz | 0.5 mT |
Ramirez E et al. | 1983 | invertebrate, <i>Drosophila melanogaster</i> (embryo and adults), whole body | magnetic field, static magnetic field, 50/60 Hz | 1–4.5 mT |
Raus S et al. | 2012 | animal, Mongolian gerbils <i>(Meriones unguiculatus)</i>, whole body | magnetic field, low frequency, 50/60 Hz | 0.2–2 mT |
Rostami A et al. | 2016 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 4 mT |
Rudolph K et al. | 1985 | animal, rat/Wistar-Füllinsdorf, whole body | magnetic field, 50/60 Hz | 40 µT |
Ryu JM et al. | 2009 | invertebrate, common cutworm larvae (<i>Spodoptera litura</i>) | magnetic field, 50/60 Hz | 1 mT |
Sakhnini L et al. | 2012 | animal, mouse, whole body | magnetic field, 50/60 Hz | 1 mT |
Sakhnini L et al. | 2014 | animal, mouse/BALB/c | 50/60 Hz, magnetic field | - |
Salunke BP et al. | 2014 | animal, mouse/Swiss albino, whole body | magnetic field, 50/60 Hz, co-exposure | 1 mT |
Salunke BP et al. | 2014 | animal, mouse/Swiss albino, whole body | magnetic field, 50/60 Hz | 1 mT |
Salzinger K et al. | 1990 | animal, rat/Sprague-Dawley, whole body | electric field, magnetic field, 50/60 Hz | 100 µT |
Shepherd S et al. | 2019 | invertebrate, Honey bee (<i>Apis mellifera</i>), whole body | magnetic field, 50/60 Hz | 100–1,000 µT |
Shepherd S et al. | 2021 | invertebrate, desert locust (<i>Schistocerca gregaria</i>) | magnetic field, 50/60 Hz, low frequency | 10–7,000 µT |
Shin EJ et al. | 2007 | animal, mouse/ICR | magnetic field, low frequency, 50/60 Hz | 0.3–2.4 mT |
Shin EJ et al. | 2011 | animal, mouse/C57BL/6, whole body | magnetic field, 50/60 Hz, co-exposure | 0.3–2.4 mT |
Sienkiewicz ZJ et al. | 1996 | animal, mouse/CD-1, whole body | magnetic field, 50/60 Hz | 5 mT |
Sienkiewicz ZJ et al. | 1996 | animal, mouse/CD-1, whole body | magnetic field, 50/60 Hz | 5 µT–5 mT |
Sienkiewicz ZJ et al. | 1998 | animal, mouse/C57BL/6J, whole body | magnetic field, 50/60 Hz | 750 µT |
Sienkiewicz ZJ et al. | 1998 | animal, mouse/C57BL/6J, whole body | magnetic field, 50/60 Hz | 7.5 µT–7.5 mT |
Smith RF et al. | 1994 | animal, rat/Long-Evans, whole body | magnetic field, low frequency, 50/60 Hz, co-exposure | 200 µT–1.9 mT |
Smith RF et al. | 1977 | animal, mice (DBA/2J and albino CD/1), whole body | 50/60 Hz, magnetic field | - |
Steenhof K et al. | 1993 | animal, bird/raptors and common raven (<i>Corvus corax</i>), whole body | 50/60 Hz, power transmission line, electric field, magnetic field | - |
Stern S et al. | 1996 | animal, rat/Long-Evans Hooded, whole body | magnetic field, static magnetic field, 50/60 Hz, DC | 26–88 µT |
Szemerszky R et al. | 2010 | animal, rat/Sprague-Dawley, whole body | electric field, magnetic field, low frequency, 50/60 Hz | 0.5 mT |
Taormina B et al. | 2019 | invertebrate, European lobster (<i>Homarus gammarus</i>), whole body | magnetic field, static magnetic field, 50/60 Hz, DC, underground cable | 225 µT |
Tasset I et al. | 2012 | animal, rat/Wistar, partial body: head | magnetic field, 50/60 Hz, TMS (transcranial stimulation), co-exposure | 0.7 mT |
Tekam CKS et al. | 2023 | intact cell/cell culture, C6 glial cells, animal, rat/Wistar | 50/60 Hz, magnetic field, signals/pulses | - |
Thomas JR et al. | 1986 | animal, rat/Long-Evans Hooded, whole body | magnetic field, static magnetic field, 50/60 Hz, DC, co-exposure | 26–50 µT |
Trzeciak HI et al. | 1993 | animal, rat/Wistar, whole body | magnetic field, static magnetic field, 50/60 Hz | 18–490 mT |
Wyszkowska J et al. | 2016 | invertebrate, desert locust (<i>Schistocerca gregaria</i>), whole body | magnetic field, 50/60 Hz, power transmission line | 1–7 mT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.