Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Iqbal M et al. | 2012 | plant, pea (<i>Pisum sativum</i>) | magnetic field, 50/60 Hz | 60–180 mT |
Isildar AA et al. | 2005 | soil | magnetic field, 50/60 Hz, power transmission line | 14.9–673.7 mA/m |
Jamil Y et al. | 2012 | fungi (mycelium), Pleurotus (<i>Pleurotus spec.</i>) | magnetic field, 50/60 Hz | 5–100 mT |
Jankowska M et al. | 2021 | isolated organ, invertebrate, American cockroach (<i>Periplaneta americana</i>) | 50/60 Hz, magnetic field, also other exposures without EMF | 7 mT |
Jeong JH et al. | 2005 | animal, rat/Sprague-Dawley, partial body: skull | magnetic field, 50/60 Hz, co-exposure | 500 µT–2 mT |
Jeong JH et al. | 2000 | animal, mouse/ICR, whole body | magnetic field, 50/60 Hz, co-exposure | 2 mT |
Jeong JH et al. | 2006 | animal, mouse/ICR, whole body | magnetic field, 50/60 Hz | 2 mT |
Jimena I et al. | 2009 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz, co-exposure | 0.7 mT |
Jin M et al. | 2000 | intact cell/cell culture, INITC3H 10T1/2 cells (derived from mouse embryo fibroblasts, transformed carcinogenically by methylcholanthrene, resulting neoplastic phenotype can be suppressed by the presence of retinyl acetate) | magnetic field, 50/60 Hz | 300 µT |
Juraskova V et al. | 1996 | intact cell/cell culture, LS/BL lymphosarcoma cells of mice and bone marrow cells of mice | magnetic field, 50/60 Hz | 10 mT |
Juszczak K et al. | 2012 | intact cell/cell culture, urothelial cells (primary culture from urinary bladders of female Wistar rats) | magnetic field, signals/pulses, 50/60 Hz, electrotherapy | 45 mT |
Kargul B et al. | 2011 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 100–500 µT |
Kavak S et al. | 2009 | animal, rat/Wistar, whole body | magnetic field, low frequency, signals/pulses, 50/60 Hz | 5 mT |
Kavaliers M et al. | 1990 | invertebrate, snail (<i>Cepaea nemoralis</i>), whole body | magnetic field, 50/60 Hz | 100 µT |
Kavaliers M et al. | 1993 | invertebrate, snail (<i>Cepaea nemoralis</i>), whole body | magnetic field, 50/60 Hz | 100 µT |
Kavaliers M et al. | 1998 | invertebrate, snail (<i>Cepaea nemoralis</i>), whole body | magnetic field, 50/60 Hz | 141 µT |
Kavaliers M et al. | 1999 | invertebrate, land snail (<i>Cepaea nemoralis</i>), whole body | magnetic field, 50/60 Hz, co-exposure | 141 µT |
Kavaliers M et al. | 1991 | invertebrate, snail (<i>Cepaea nemoralis</i>), whole body | magnetic field, 50/60 Hz | 100 µT |
Kavaliers M et al. | 1985 | animal, mouse/CF-1 and mouse/C57BL, whole body | magnetic field, 50/60 Hz | 0–9 mT |
Kielbasa P et al. | 2022 | isolated bio./chem. substance, essential oil samples (tea tree and cedarwood) | magnetic field, 50/60 Hz | - |
Kilfoyle AK et al. | 2018 | animal, fish, whole body | magnetic field, static magnetic field, high-voltage direct current (HVDC), underground cable, 50/60 Hz, DC | 0.4–559 nT |
Kim HJ et al. | 2013 | intact cell/cell culture, mesenchymal bone marrow stem cells | 50/60 Hz, magnetic field | 1 mT |
Kim HS et al. | 2014 | animal, mouse/BALB/c, whole body | magnetic field, 50/60 Hz | 2–200 µT |
Kim SK et al. | 2013 | human, partial body: head | magnetic field, 50/60 Hz | 12.5 µT |
Kim YM et al. | 2017 | - | magnetic field, low frequency, 50/60 Hz | - |
Kiray A et al. | 2013 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 3 mT |
Kirschvink J et al. | 1997 | invertebrate, honeybee (<i>Apis mellifera carnica</i>) | magnetic field, low frequency, 50/60 Hz | 1.3–1,300 µT |
Krueger WF et al. | 1972 | animal, young chicken, whole body | TV broadcast (VHF/UHF), electric field, magnetic field, 50/60 Hz | - |
Kubinyi G et al. | 1998 | animal, mouse/CFLP (embryos and adults), whole body | magnetic field, 50/60 Hz | 100 µT |
Kula B et al. | 1996 | intact cell/cell culture, fibroblasts | magnetic field, static magnetic field, low frequency, 50/60 Hz | 20–490 mT |
Kumar S et al. | 2010 | animal, rat/Wistar | magnetic field, 50/60 Hz | 17.96 µT |
Kumar S et al. | 2013 | animal, rat/ Wistar, whole body | magnetic field, 50/60 Hz, therapeutic/medical device | 17.96 µT |
Kumar S et al. | 2021 | animal, rat/Wistar | magnetic field, 50/60 Hz, low frequency | 17.96 µT |
Lee HJ et al. | 2012 | intact cell/cell culture, NIH3T3 cells (mouse fibroblasts), normal and transfected with a c-Myc-containing vector or with an empty vetor | magnetic field, low frequency, 50/60 Hz, co-exposure | 0.01–1 mT |
Legros A et al. | 2005 | human, partial body: head (trunk and arms) | magnetic field, low frequency, 50/60 Hz | 1 mT |
Legros A et al. | 2006 | human, partial body: head | magnetic field, 50/60 Hz | 1 mT |
Legros A et al. | 2006 | human, partial body: head | magnetic field, 50/60 Hz | 1 mT |
Liebl MP et al. | 2015 | animal, mouse/APP23, SOD1<sup>G85R</sup>, SOD1<sup>G93A</sup>, SOD1<sup>WT</sup>, wild type, whole body | magnetic field, 50/60 Hz | 1 mT |
Lisi A et al. | 2006 | intact cell/cell culture, HaCaT cells (human keratinocytes cell line) | magnetic field, 50/60 Hz | 1 mT |
Liu Y et al. | 2015 | intact cell/cell culture, GC-2 cells (murine spermatocyte-derived cell line) | magnetic field, 50/60 Hz | 1–3 mT |
Loberg LI et al. | 2000 | intact cell/cell culture, <i>Ataxia telangiectasia</i> and normal human lymphoblastoid cell lines | magnetic field, 50/60 Hz, co-exposure | 1 mT |
Lopucki M et al. | 2004 | isolated organ, human placenta | magnetic field, 50/60 Hz | 2–5 mT |
Lorimore SA et al. | 1990 | animal, mouse/CBA/H | magnetic field, 50/60 Hz | 20 mT |
Lotfi A et al. | 2011 | animal, mouse/BALB/c, whole body | magnetic field, low frequency, signals/pulses, 50/60 Hz | 50 mT |
Lovely RH et al. | 1992 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 3.03 mT |
Lundberg L et al. | 2019 | - | 50/60 Hz, magnetic field, co-exposure, also other exposures without EMF | - |
Luo Q et al. | 2006 | ICR mouse embryo cultures | 50/60 Hz, magnetic field, low frequency, co-exposure | 0.3–0.5 mT |
Magazu S et al. | 2010 | isolated bio./chem. substance, aqueous haemoglobin solution | magnetic field, low frequency, 50/60 Hz | 1 mT |
Magazu S et al. | 2011 | bovine serum albumin in H<sub>2</sub>O and D<sub>2</sub>O solutions | magnetic field, static magnetic field, 50/60 Hz, DC | 1.8–200 mT |
Mahato S et al. | 2023 | isolated bio./chem. substance, myofibrillar protein from grass carp | magnetic field, 50/60 Hz, low frequency, also other exposures without EMF, co-exposure | - |