Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Akbarnejad Z et al. | 2017 | intact cell/cell culture, U87 (human glioblastoma cell line) | magnetic field, signals/pulses, 50/60 Hz | 5–10 mT |
Alipour M et al. | 2022 | intact cell/cell culture, rat bone marrow-derived mesenchymal cells (BMSCs) | static magnetic field, magnetic field, 50/60 Hz, co-exposure | - |
An GZ et al. | 2015 | intact cell/cell culture, BALB/3T3 cells (embryonal mouse fibroblasts) | magnetic field, 50/60 Hz | 2.3 mT |
Antonopoulos A et al. | 1995 | intact cell/cell culture, human peripheral blood | magnetic field, 50/60 Hz | 5 mT |
Brisdelli F et al. | 2014 | intact cell/cell culture, K562 cells (human erythroleukemic cell line) | magnetic field, 50/60 Hz, co-exposure | 0.01–2 mT |
Cios A et al. | 2021 | intact cell/cell culture, HEK293 (kidney cells), 786-O, 769-P, and Caki1 (clear cell renal carcinoma cell lines) | magnetic field, 50/60 Hz | 4.5 mT |
Cohen MM et al. | 1986 | intact cell/cell culture, human peripheral blood and 5 lymphoblastoid cell lines (normal - GM 1525, ataxia telangiectasia - GM 1525, xeroderma pigmentosum - D 7031, Bloom syndrome - GM 4408, Fanconi anemia - HSC 230) | electric field, magnetic field, 50/60 Hz | 0.1–0.2 mT |
Cohen MM et al. | 1986 | intact cell/cell culture, human peripheral blood lymphocytes | electric field, magnetic field, 50/60 Hz | 100–200 µT |
Cossarizza A et al. | 1993 | intact cell/cell culture, human peripheral blood mononuclear cells | electric field, magnetic field, signals/pulses, 50/60 Hz | 2.5 mT |
Cridland NA et al. | 1999 | intact cell/cell culture, HF-19 cells (human fetal lung fibroblasts) | magnetic field, 50/60 Hz | 20 µT–20 mT |
Dees C et al. | 1996 | intact cell/cell culture, MCF-7 and T-47D cell lines (human breast cancer cell lines) | magnetic field, 50/60 Hz, co-exposure | 1.2–900 µT |
Delle Monache S et al. | 2013 | intact cell/cell culture, human umbilical vein endothelial cells (HUVEC) and mouse pancreatic endothelial cell line (MS-1) | magnetic field, low frequency, 50/60 Hz | 1–2 mT |
Denaro V et al. | 2011 | intact cell/cell culture | low frequency, signals/pulses, 50/60 Hz, magnetic field | 0.4 mT |
Ding GR et al. | 2001 | intact cell/cell culture, MCF-7 (human breast cancer cell line) | magnetic field, 50/60 Hz, co-exposure | 5 mT |
Eremenko T et al. | 1997 | intact cell/cell culture, Friend erythroleukemia cell line (clone 745 A) | magnetic field, geomagnetic field, 50/60 Hz, shielding/field deprivation | 0.0025 nT–70 µT |
Gaafar RM et al. | 2018 | plant, broad Bean (<i>Vicia faba</i>) | 50/60 Hz, power transmission line, magnetic field, electric field | 720–4,051 µT |
Giorgi G et al. | 2014 | intact cell/cell culture, human neuroblastoma cell line (BE(2)C) | magnetic field, 50/60 Hz, co-exposure | 1 mT |
Goodman EM et al. | 1976 | intact cell/cell culture, slime mold microplasmodia (<i>Physarum polycephalum</i>, line M<sub>3</sub>C VI) | electric field, magnetic field, low frequency, 50/60 Hz | 200 µT |
Guo H et al. | 2004 | intact cell/cell culture, SNU cells (human gastric adenocarcinoma cell line) | magnetic field, 50/60 Hz | 97 mT |
Harris PA et al. | 2002 | intact cell/cell culture, HeLa S3 (human cervical carcinoma cell line) | magnetic field, 50/60 Hz | 2 mT |
Huang CY et al. | 2014 | intact cell/cell culture, HaCaT cells (human keratinocytes) partially transfected with CHK2 siRNA | magnetic field, 50/60 Hz, shielding/field deprivation | 1.5 mT |
Huang CY et al. | 2014 | intact cell/cell culture, human epidermal keratinocytes (derived from neonatal foreskin) and HaCaT cells (human keratinocytes) | magnetic field, 50/60 Hz | 1.5 mT |
Jin H et al. | 2015 | intact cell/cell culture, L123 cells (human lung epithelial cells) | magnetic field, 50/60 Hz, co-exposure | 1–2 mT |
Khalil AM et al. | 1991 | intact cell/cell culture, human peripheral blood | magnetic field, signals/pulses, 50/60 Hz | 1.05 mT |
Koh EK et al. | 2008 | intact cell/cell culture, different human prostate carcinoma cell lines (DU145, LNCaP, PC3) | magnetic field, 50/60 Hz, power transmission line | 0.2–2.5 mT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.