Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Verheyen GR et al. | 2003 | intact cell/cell culture, human lymphocytes | magnetic field, 50/60 Hz, co-exposure | 80–800 µT |
Berg H et al. | 2003 | intact cell/cell culture, K562 cells (human erythroleukemic cell line) and U937 cells (human leukemic monocyte cell line) and human lymphocytes | magnetic field, 50/60 Hz, co-exposure | 10–35 mT |
Lai H et al. | 2004 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz, co-exposure | 10–500 µT |
Berg H | 2003 | intact cell/cell culture, human myeloid leukemia cell line (K-562) and human non-Hodgkin lymphoma cell line (U-937) | magnetic field, 50/60 Hz, co-exposure | 8–55 mT |
Khadir R et al. | 1999 | intact cell/cell culture, neutrophils (from human venous blood) | magnetic field, 50/60 Hz, co-exposure | 0.1–44 mT |
Kumlin T et al. | 2002 | animal, mouse/BALB/CŒDBA/2, whole body | magnetic field, 50/60 Hz, co-exposure | 100 µT |
Markkanen A et al. | 2008 | intact cell/cell culture, L929 cells (murine fibroblast cells) | magnetic field, 50/60 Hz, co-exposure | 100–300 µT |
Kurian MV et al. | 2012 | intact cell/cell culture, H9c2 cells (myoblast from embryonal rat myocard) | magnetic field, 50/60 Hz, co-exposure | 1–240 µT |
Cho S et al. | 2014 | intact cell/cell culture, human lymphocytes | magnetic field, 50/60 Hz, co-exposure | 0.8 mT |
Jia HL et al. | 2014 | intact cell/cell culture, PC-12 cells (pheochromocytoma cell line from rat adrenal gland) | magnetic field, 50/60 Hz, co-exposure | 400 µT |
Brisdelli F et al. | 2014 | intact cell/cell culture, K562 cells (human erythroleukemic cell line) | magnetic field, 50/60 Hz, co-exposure | 0.01–2 mT |
Giorgi G et al. | 2014 | intact cell/cell culture, human neuroblastoma cell line (BE(2)C) | magnetic field, 50/60 Hz, co-exposure | 1 mT |
Benassi B et al. | 2016 | intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) | magnetic field, 50/60 Hz, co-exposure | 1 mT |
Baharara J et al. | 2016 | intact cell/cell culture, A2780 cells (cisplatin-resistant human ovarian adenocarcinoma cells) | magnetic field, 50/60 Hz, co-exposure | 20 mT |
Yin C et al. | 2016 | intact cell/cell culture, primary hippocampal neurons from newborn Sprague-Dawley rats | magnetic field, 50/60 Hz, co-exposure | 8 mT |
Zhang H et al. | 2016 | animal, mouse/ICR | magnetic field, 50/60 Hz, co-exposure | 8 mT |
Han Q et al. | 2018 | - | magnetic field, 50/60 Hz, co-exposure | - |
Xu A et al. | 2020 | - | magnetic field, 50/60 Hz, low frequency | - |
Aparicio-Bautista DI et al. | 2022 | intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) | magnetic field, 50/60 Hz, low frequency | - |
Ambalayam S et al. | 2022 | animal, rat/Wistar | magnetic field, 50/60 Hz, low frequency | - |
Kayhan H et al. | 2020 | intact cell/cell culture, human, neonatal, healthy primary dermal fibroblast and MCF7 cells (human metastatic breast cancer cells) | magnetic field, 50/60 Hz, low frequency | - |
Koh EK et al. | 2008 | intact cell/cell culture, different human prostate carcinoma cell lines (DU145, LNCaP, PC3) | magnetic field, 50/60 Hz, power transmission line | 0.2–2.5 mT |
Palumbo R et al. | 2006 | intact cell/cell culture, Jurkat cells (T lymphocyte hybridoma cell line) | magnetic field, 50/60 Hz, power transmission line, co-exposure | 1 mT |
Solek P et al. | 2017 | intact cell/cell culture, GC-1 cells (murine spermatogonia cell line); GC-2 cells (murine spermatocyte cell line) | magnetic field, 50/60 Hz, signals/pulses | 2.5–8 mT |
Oda T et al. | 2004 | intact cell/cell culture, rat cerebellar granule cells | magnetic field, low frequency, 50/60 Hz | 300 mT |