Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Sun ZC et al. | 2016 | animal, mouse/C57, whole body | magnetic field, 50/60 Hz | 1 mT |
Ma Q et al. | 2016 | intact cell/cell culture, embryonic neural stem cells (mouse/BALB/c) | magnetic field, 50/60 Hz | 1 mT |
Zhang H et al. | 2017 | animal, mouse/ICR | magnetic field, 50/60 Hz | 8 mT |
Zhang Y et al. | 2018 | - | magnetic field, 50/60 Hz | - |
Wu X et al. | 2018 | intact cell/cell culture, human amniotic epithelium cells (FL), rat pheochromocytoma cells (PC12) | magnetic field, 50/60 Hz | 0.4 mT |
Pazur A et al. | 2009 | plant, <i>Arabidopsis thaliana</i> (equorin expressing mutant <i>Col0-1 Aeq Cy+</i>) and wild type | magnetic field, 50/60 Hz, DC, static magnetic field | 0.1–65.8 µT |
Lee YJ et al. | 2015 | intact cell/cell culture, human bone marrow-derived mesenchymal stem cells (hBM-MSCs) | magnetic field, 50/60 Hz, also other exposures without EMF, co-exposure | - |
Walleczek J et al. | 1990 | intact cell/cell culture, rat thymocytes | magnetic field, 50/60 Hz, co-exposure | 22 T |
Morgado-Valle C et al. | 1998 | intact cell/cell culture, chromaffin cells (from postnatal Wistar rat adrenal medulla) | magnetic field, 50/60 Hz, co-exposure | 700 µT |
Liu DD et al. | 2014 | intact cell/cell culture, rat cerebellar granule cells | magnetic field, 50/60 Hz, co-exposure | 1 mT |
de Groot MW et al. | 2014 | intact cell/cell culture, PC-12 cells (pheochromocytoma cell line from rat adrenal gland) | magnetic field, 50/60 Hz, co-exposure | 1–1,000 µT |
Özgün A et al. | 2018 | - | magnetic field, 50/60 Hz, co-exposure | - |
Jedrzejczak-Silicka M et al. | 2021 | intact cell/cell culture, L929 cells (murine fibroblast cells) and HaCaT cells (human keratinocytes cell line) | magnetic field, 50/60 Hz, low frequency | 5.9–28.4 mT |
Ye AF et al. | 2022 | intact cell/cell culture, human amniotic epithelial cells (FL) | magnetic field, 50/60 Hz, low frequency | - |
Mattsson MO et al. | 2001 | intact cell/cell culture, Jurkat cells (clone E6-1; T-lymphocyte hybridoma cell line) from three different sources | magnetic field, 50/60 Hz, static magnetic field, shielding/field deprivation | 150 µT |
Lindstrom E et al. | 1995 | intact cell/cell culture, Jurkat cells (human lymphoblastoid T cells) | magnetic field, low frequency, 50/60 Hz | 40–150 µT |
Pilger A et al. | 2004 | intact cell/cell culture, human diploid fibroblast cells | magnetic field, low frequency, 50/60 Hz | 1 mT |
Hanafy E et al. | 2008 | animal, guinea pig, whole body | magnetic field, low frequency, 50/60 Hz | 0.2 mT |
Morabito C et al. | 2010 | intact cell/cell culture, C2C12 cells (undifferentiated myoblasts and differentiated myotubes) | magnetic field, low frequency, 50/60 Hz | 0.1–1 mT |
Morabito C et al. | 2010 | intact cell/cell culture, PC-12 cells | magnetic field, low frequency, 50/60 Hz | 0.1–1 mT |
Sert C et al. | 2011 | animal, rat/Sprague-Dawley, whole body | magnetic field, low frequency, 50/60 Hz | 0.25 mT |
Hwang YH et al. | 2011 | intact cell/cell culture, RBL-2H3 (rat basophilic leukemia cells) | magnetic field, low frequency, 50/60 Hz | 0.1–1 mT |
Jung JH et al. | 2017 | intact cell/cell culture, human mesenchymal stem cells | magnetic field, low frequency, 50/60 Hz | - |
Coulton LA et al. | 1993 | intact cell/cell culture, T-lymphocytes isolated from BALB/c mouse thymus | magnetic field, low frequency, 50/60 Hz, DC, static magnetic field | 20.9–65.3 µT |
Duong CN et al. | 2016 | intact cell/cell culture, HMO6 cells (human microglial cell line) | magnetic field, low frequency, 50/60 Hz, co-exposure | 0.01–1 mT |