Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on magnetic power frequency fields (50/60 Hz)

2043 studies in total
  1. 764 studies
  2. 632 studies
  3. 511 studies
  4. 413 studies
  5. 328 studies
  6. 207 studies

Cells

511 studies in total
  1. 251 studies
  2. 125 studies
  3. 98 studies
  4. 89 studies
  5. 86 studies
  6. 67 studies
  7. 7 studies

Cell cycle 67 studies in total

Authors Year Exposed system Parameters Magnetic flux density/field strength
Sul AR et al. 2006 intact cell/cell culture, hFOB 1.19 (human fetal osteoblasts), T/G HA-VSMC (human aortic vascular smooth muscle cells), RPMI 7666 (human B lymphoblasts) and HCN-2 (human cortical neuronal cells) magnetic field, 50/60 Hz 2 mT
Su L et al. 2017 intact cell/cell culture, U251 and A127 (human glioblastoma cell lines), SH-SY5Y (human neuroblastoma cell line), rat astrocytes, rat microglia, primary cortical neurons (of rat) magnetic field, low frequency, 50/60 Hz 2 mT
Sun C et al. 2018 intact cell/cell culture, mouse embryonic fibroblasts (wild type and <i>Atm</i>-deficient) 50/60 Hz, magnetic field 2 mT
Koziorowska A et al. 2017 intact cell/cell culture, pig anterior pituitary gland cells magnetic field, 50/60 Hz, low frequency 2–6 mT
An GZ et al. 2015 intact cell/cell culture, BALB/3T3 cells (embryonal mouse fibroblasts) magnetic field, 50/60 Hz 2.3 mT
Ruiz-Gomez MJ et al. 2010 intact cell/cell culture, yeast (<i>Saccharomyces cerevisiae</i>)/wild type (WS8105-1C) and <i>rad52 hdf1</i> mutants (<i>rad52</i>, <i>hdf1</i>, <i>rad52 hdf1</i>; radiation sensitive 52, high affinity DNA binding factor 1) magnetic field, 50/60 Hz 2.45 mT
Cossarizza A et al. 1993 intact cell/cell culture, human peripheral blood mononuclear cells electric field, magnetic field, signals/pulses, 50/60 Hz 2.5 mT
Koziorowska A et al. 2017 intact cell/cell culture, human neonatal fibroblast BJ 50/60 Hz, magnetic field, low frequency, signals/pulses 2.5 mT
Solek P et al. 2017 intact cell/cell culture, GC-1 cells (murine spermatogonia cell line); GC-2 cells (murine spermatocyte cell line) magnetic field, 50/60 Hz, signals/pulses 2.5–8 mT
Cios A et al. 2021 intact cell/cell culture, HEK293 (kidney cells), 786-O, 769-P, and Caki1 (clear cell renal carcinoma cell lines) magnetic field, 50/60 Hz 4.5 mT
Antonopoulos A et al. 1995 intact cell/cell culture, human peripheral blood magnetic field, 50/60 Hz 5 mT
Ding GR et al. 2001 intact cell/cell culture, MCF-7 (human breast cancer cell line) magnetic field, 50/60 Hz, co-exposure 5 mT
Tian F et al. 2002 intact cell/cell culture, CHO-K1 (Chinese hamster ovary K1) cells (Ku80-proficient) und xrs5 cells (Ku80-defizient; radiation sensitive mutant isolated from CHO-K1 cells) magnetic field, 50/60 Hz, co-exposure 5 mT
Zhang M et al. 2013 intact cell/cell culture, human epidermal stem cells magnetic field, low frequency, 50/60 Hz 5 mT
Akbarnejad Z et al. 2017 intact cell/cell culture, U87 (human glioblastoma cell line) magnetic field, signals/pulses, 50/60 Hz 5–10 mT
Li X et al. 2012 intact cell/cell culture, mesenchymal bone marrow stem cells (from femurae and tibiae of Sprague-Dawley rats) magnetic field, signals/pulses, 50/60 Hz 10 mT
Guo H et al. 2004 intact cell/cell culture, SNU cells (human gastric adenocarcinoma cell line) magnetic field, 50/60 Hz 97 mT