Study overviews

Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.

Experimental studies on magnetic power frequency fields (50/60 Hz)

2042 studies in total
  1. 763 studies
  2. 632 studies
  3. 511 studies
  4. 413 studies
  5. 328 studies
  6. 207 studies

DNA, proteins, and oxidative stress

632 studies in total
  1. 254 studies
  2. 211 studies
  3. 182 studies
  4. 47 studies
Authors Year Exposed system Parameters Magnetic flux density/field strength
Verschaeve L et al. 2011 bacterium, <i>Salmonella typhimurium</i>/TA-104-recN2-4 (with luciferase gene and recN promoter: produces light when DNA is damaged) & TA104-pr1 (with lux gene under a constitutive promoter: light production not influenced by genotoxic compounds (internal control)) magnetic field, low frequency, 50/60 Hz, co-exposure 100–500 µT
Luukkonen J et al. 2011 intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) magnetic field, low frequency, 50/60 Hz, co-exposure 100 µT
Gadhia P et al. 2010 human, whole body magnetic field, 50/60 Hz, occupational, co-exposure -
Ruiz-Gomez MJ et al. 2010 intact cell/cell culture, yeast (<i>Saccharomyces cerevisiae</i>)/WS8105-1C (genotype <i>MATalpha, ade2, arg4-17, trp1-289, ura3-52</i>: a marker which stains the colonies red) magnetic field, static magnetic field, 50/60 Hz, DC 0.35–2.45 mT
Kim J et al. 2010 intact cell/cell culture, HeLa cell line (human adenocarcinoma cell line) and IMR90 (human lung fibroblasts) magnetic field, 50/60 Hz 3–6 mT
Mariucci G et al. 2010 animal, mouse/CD-1, whole body magnetic field, 50/60 Hz 1 mT
Ruiz-Gomez MJ et al. 2010 intact cell/cell culture, yeast (<i>Saccharomyces cerevisiae</i>)/wild type (WS8105-1C) and <i>rad52 hdf1</i> mutants (<i>rad52</i>, <i>hdf1</i>, <i>rad52 hdf1</i>; radiation sensitive 52, high affinity DNA binding factor 1) magnetic field, 50/60 Hz 2.45 mT
Okudan N et al. 2010 animal, mouse/Swiss albino, whole body magnetic field, low frequency, 50/60 Hz 5 µT
Focke F et al. 2010 intact cell/cell culture, HeLa cell line (human adenocarcinoma cell line), MRC-5 (human primary fetal lung fibroblasts), and human primary fibroblasts low frequency, 50/60 Hz, power transmission line, magnetic field 1 mT
Celikler S et al. 2009 human, whole body electric field, magnetic field, 50/60 Hz, power transmission line, electrical substation, occupational 0.25–17 A/m
Burdak-Rothkamm S et al. 2009 intact cell/cell culture, human fibroblasts magnetic field, 50/60 Hz 50–1,000 µT
Albert GC et al. 2009 human, whole body magnetic field, 50/60 Hz 200 µT
Yokus B et al. 2008 animal, rat/Sprague-Dawley, whole body magnetic field, 50/60 Hz 100–500 µT
Cellini L et al. 2008 bacterium, <i>Escherichia coli</i>/ATCC 700926 magnetic field, low frequency, 50/60 Hz 0.1–1 mT
Koyama S et al. 2008 intact cell/cell culture, A172 (human glioblastoma cells) magnetic field, 50/60 Hz, co-exposure 5 mT
Cho YH et al. 2007 intact cell/cell culture, CCD-986sk (human fibroblasts) magnetic field, low frequency, 50/60 Hz, co-exposure 0.8 mT
Erdal N et al. 2007 animal, rat/Wistar, whole body magnetic field, 50/60 Hz 1 mT
Wahab MA et al. 2007 intact cell/cell culture magnetic field, 50/60 Hz 1 µT–1 mT
Mairs RJ et al. 2007 intact cell/cell culture, UVW (human glioma cell line) magnetic field, 50/60 Hz 1 mT
Hone P et al. 2006 intact cell/cell culture magnetic field, 50/60 Hz, co-exposure 0.23–0.7 mT
Frahm J et al. 2006 intact cell/cell culture, macrophages (mouse) magnetic field, 50/60 Hz 0.05–1 mT
Udroiu I et al. 2006 animal, mouse/CD-1 Swiss, whole body magnetic field, low frequency, 50/60 Hz 650 µT
Luo Q et al. 2006 ICR mouse embryo cultures 50/60 Hz, magnetic field, low frequency, co-exposure 0.3–0.5 mT
Williams PA et al. 2006 bacterium, <i>Salmonella typhimurium</i>/LT2 (TT22240; TT24257; TT24470) magnetic field, 50/60 Hz, inhouse wiring, other domestic appliance 14.6 mT
Villarini M et al. 2006 intact cell/cell culture magnetic field, 50/60 Hz, co-exposure 3 mT