Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Parameters | Magnetic flux density/field strength |
---|---|---|---|---|
Kubinyi G et al. | 1998 | animal, mouse/CFLP (embryos and adults), whole body | magnetic field, 50/60 Hz | 100 µT |
Attia AA et al. | 2002 | animal, mouse/Swiss albino, whole body | magnetic field, low frequency, 50/60 Hz | 100 µT |
Lai J et al. | 2016 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 100 µT |
Rajkovic V et al. | 2005 | animal, rat/Wistar, whole body | electric field, magnetic field, 50/60 Hz | 100–300 µT |
Rajkovic V et al. | 2005 | animal, rat/Wistar, whole body | electric field, magnetic field, low frequency, 50/60 Hz | 100–300 µT |
Zhang Y et al. | 2020 | animal, rat/Sprague Dawley, whole body | 50/60 Hz, magnetic field | 100–500 µT |
Cabrales LB et al. | 2001 | animal, mouse/Balb/c, whole body | magnetic field, 50/60 Hz | 110 µT |
Ibrahim M et al. | 2008 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 0.2–1.4 mT |
Devevey L et al. | 2000 | animal, rat/Brown Norway, whole body | magnetic field, 50/60 Hz | 500 µT |
Zhang Y et al. | 2020 | animal, rat/Sprague Dawley | 50/60 Hz, magnetic field | 500 µT |
Ottani V et al. | 1984 | animal, rat/ Wistar albino, whole body | magnetic field, low frequency, signals/pulses, 50/60 Hz | 600 µT–6 mT |
Ottani V et al. | 1997 | animal, rat/Wistar albino, whole body | signals/pulses, 50/60 Hz, magnetic field | 600 µT–8 mT |
Anderson LE et al. | 2001 | animal, rat/Fischer 344, whole body | magnetic field, 50/60 Hz | 1 mT |
Aksen F et al. | 2006 | animal, rat/Wistar albino, whole body | magnetic field, 50/60 Hz | 1 mT |
Erdal N et al. | 2008 | animal, rat/Wistar albino, whole body | magnetic field, 50/60 Hz | 1 mT |
Wang J et al. | 2021 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 1 mT |
Tofani S et al. | 2002 | animal, mouse/CD-1 nu-nu (nude), whole body | magnetic field, static magnetic field, 50/60 Hz | 1–5.5 mT |
Del Carratore R et al. | 1995 | animal, mouse/Swiss albino and rat/Wistar, whole body | magnetic field, 50/60 Hz, co-exposure | 1.2 mT |
Lahijani MS et al. | 2013 | animal, chicken embryos (eggs), whole body | magnetic field, low frequency, 50/60 Hz | 1.33–7.32 mT |
Akdag Z et al. | 2006 | animal, rat/Sprague-Dawley, whole body | magnetic field, 50/60 Hz | 1.35 mT |
Babbitt JT et al. | 2000 | animal, mouse/C57BL/6, whole body | magnetic field, 50/60 Hz, co-exposure | 1.42 mT |
Tunik S et al. | 2013 | animal, rat/Wistar albino, whole body | magnetic field, signals/pulses, 50/60 Hz | 1.5 mT |
Erdem O et al. | 2018 | animal, guinea pig, whole body | magnetic field, 50/60 Hz | 1.5 mT |
Lopucki M et al. | 2003 | isolated organ, human placentae (after delivery) | magnetic field, 50/60 Hz | 2 mT |
Torres-Duran PV et al. | 2007 | animal, rat/Wistar | magnetic field, 50/60 Hz | 2.4 mT |
Razavi SM et al. | 2017 | animal, mouse/BALB/c | magnetic field, low frequency, 50/60 Hz, also other exposures without EMF, co-exposure | 3 mT |
Öcal I et al. | 2004 | animal, rat/Wistar albino, whole body | magnetic field, 50/60 Hz | 5 mT |
Eraslan G et al. | 2004 | animal, mouse/albino | magnetic field, 50/60 Hz | 5 mT |
Li BL et al. | 2015 | animal, rat/Wistar, whole body | magnetic field, signals/pulses, 50/60 Hz | 5–20 mT |
Gimenez-Gonzalez M et al. | 1991 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 5.2 mT |
Zecca L et al. | 1985 | animal, rat/Sprague Dawley (embryo and adult), whole body | magnetic field, signals/pulses, 50/60 Hz | 5.8 mT |
Bellossi A et al. | 1998 | animal, rat/Wistar, whole body | magnetic field, low frequency, signals/pulses, 50/60 Hz | 6 mT |
Khaki AA et al. | 2006 | animal, rat/Wistar, whole body | magnetic field, 50/60 Hz | 8 mT |
Zhang H et al. | 2016 | animal, mouse/ICR | magnetic field, 50/60 Hz, co-exposure | 8 mT |
Drzewiecka EM et al. | 2021 | isolated organ, tissue slices, fragments of myometrium | magnetic field, 50/60 Hz, low frequency | 8 mT |
Malter M et al. | 1987 | animal, rat and mouse | signals/pulses, 50/60 Hz, magnetic field | 13.5–26.2 mT |
Kula B et al. | 2000 | animal, rat/Wistar, whole body | magnetic field, static magnetic field, low frequency, 50/60 Hz | 0.018–0.49 T |
Vignola MB et al. | 2012 | animal, rat/Wistar, whole body | magnetic field, signals/pulses, 50/60 Hz, therapeutic/medical device | 20 mT |
Duda D et al. | 1991 | animal, rat/Wistar, whole body | magnetic field, static magnetic field, low frequency, 50/60 Hz | 20–490 mT |
Fam WZ et al. | 1996 | animal, mouse/CFW, whole body | magnetic field, 50/60 Hz | 25 mT |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.