Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Regel SJ et al. | 2007 | ヒト, 身体の一部: head | waking EEG, cognitive performance | 900 MHz | 1 W/kg | continuous for 30 min | デジタル携帯電話, GSM, 移動体通信システム |
Trunk A et al. | 2013 | ヒト, 身体の一部: head | - | 1,947 MHz | 1.75–3.75 W/kg | continuous for 30 min | デジタル携帯電話, UMTS, 移動体通信システム |
Loughran SP et al. | 2013 | ヒト, 身体の一部: head | waking EEG, cognitive performance | 900 MHz | 0.35–1.4 W/kg | continuous for 30 min | 携帯電話, GSM, 移動体通信システム, PW パルス波 |
Schmid MR et al. | 2012 | ヒト, 身体の一部: left side of the head | working memory, attention, reaction time, polysomnography | 900 MHz | 2 W/kg | continuous for 30 min. | GSM, 移動体通信システム, PW パルス波 |
Verrender A et al. | 2016 | ヒト, 身体の一部: left side of head | visual discrimination and working memory | 920 MHz | 1–2 W/kg | continuous for 30 minutes | 携帯電話, GSM, 移動体通信システム |
Saikhedkar N et al. | 2014 | 動物, rat/Wistar, 全身 | structure and function of the rat brain and oxidative stress | 900 MHz | 0.99 W/kg | continuous for 4 h/day for 15 days | 携帯電話, 移動体通信システム |
Cinel C et al. | 2007 | ヒト, 身体の一部: head (left or right side) | cognitive processing | 888 MHz | 1.4–11.2 W/kg | continuous for 40 min | デジタル携帯電話, GSM, 移動体通信システム |
Curcio G et al. | 2004 | ヒト, 身体の一部: head | psychomotor and cognitive performance, tympanic temperature | 902.4 MHz | 0.5 W/kg | continuous for 45 min | デジタル携帯電話, GSM, 移動体通信システム |
Regel SJ et al. | 2006 | ヒト, 全身 | well-being, cognitive performance, and perceived field strength | 2,140 MHz | 6.2 µW/kg–32 mW/kg | continuous for 45 min | 携帯電話基地局, UMTS, 移動体通信システム |
Riddervold IS et al. | 2008 | ヒト, 全身 | cognitive performance | 2,140 MHz | - | continuous for 45 min | 携帯電話基地局, UMTS, 移動体通信システム |
Curcio G et al. | 2012 | ヒト, 身体の一部: right ear | brain BOLD (blood-oxygen-level dependent) response, somatosensory reaction time task | 902.4 MHz | 0.212–1.25 W/kg | continuous for 45 min | デジタル携帯電話, GSM, 移動体通信システム, PW パルス波 |
Vecchio F et al. | 2012 | ヒト, 身体の一部: left side of the head | cortical activity (EEG), visual reaction time task | 902.4 MHz | 0.5 W/kg | continuous for 45 min | デジタル携帯電話, GSM, 移動体通信システム, PW パルス波 |
Cinel C et al. | 2008 | ヒト, 身体の一部: right or left ear | short-term memory, vigilance, attention | 888 MHz | 1.4–11.2 W/kg | continuous for 45 min (experiment 1) or 40 min (experiment 2) | 携帯電話, デジタル携帯電話, GSM, 移動体通信システム, RF電磁界 |
Maier R et al. | 2004 | ヒト, 身体の一部: head (left ear) | cognitive processing | 902 MHz | - | continuous for 50 min | GSM, 移動体通信システム |
Eltiti S et al. | 2009 | ヒト, 全身 | cognitive functioning: short-term memory, attention and perceptual motor speed, working memory, blood volume pulse, heart rate, skin conductance | 900–1,800 MHz | - | continuous for 50 min | 携帯電話基地局, GSM, UMTS, 移動体通信システム |
Leung S et al. | 2011 | ヒト, 身体の一部: left/right hemisphere | event-related potentials and performance during oddball paradigma and n-back task | 894.6 MHz | 0.7–1.7 W/kg | continuous for 55 min | GSM, W-CDMA, 移動体通信システム |
Keetley V et al. | 2006 | ヒト, 身体の一部: head (left ear) | cognitive functioning | 900 MHz | - | continuous for 60 min | デジタル携帯電話, GSM, 移動体通信システム |
Haarala C et al. | 2003 | ヒト, 身体の一部: head | cognitive functioning | 902 MHz | 0.88–1.2 W/kg | continuous for 65 min | GSM, 移動体通信システム |
Haarala C et al. | 2004 | ヒト, 身体の一部: head (left side) | short term memory | 902 MHz | 0.99–2.07 W/kg | continuous for 65 min | GSM, 移動体通信システム |
Koivisto M et al. | 2000 | ヒト, 身体の一部: head | cognitive functioning | 902 MHz | - | continuous for about 1 h | GSM, 移動体通信システム |
Koivisto M et al. | 2000 | ヒト, 身体の一部: head | working memory | 902 MHz | - | continuous for about 30 min | GSM, 移動体通信システム |
Kleinlogel H et al. | 2008 | ヒト, 身体の一部: left ear | effects on event related potentials and cognitive function | 0.9 GHz | 0.1–1 W/kg | continuous for about 30 min | デジタル携帯電話, GSM, UMTS, CDMA, 移動体通信システム |
Russo R et al. | 2006 | ヒト, 身体の一部: head (left or right ear) | attention/cognitive function | 888 MHz | 1.4–11.2 W/kg | continuous for about 35 - 40 min | GSM, 移動体通信システム |
Papageorgiou CC et al. | 2004 | ヒト, 身体の一部: right ear | brain activity/EEG | 900 MHz | - | continuous for about 45 min | 移動体通信システム, 携帯電話 |
Nanou E et al. | 2005 | ヒト, 身体の一部: head | EEG during an auditory memory task | 900 MHz | - | continuous for about 45 min | 移動体通信システム, 携帯電話 |
このウェブサイトはクッキー(Cookies)を使って、最善のブラウジングエクスペリエンスを提供しています。あなたがこのウェブサイトを継続して使用することで、私たちがクッキーを使用することを許可することになります。