Mobile phone related articles are
Please note that a publication can be assigned to several endpoints, i.e. the sum of publications from the individual thematic points and subpoints can be greater than the total sum of actual publications.
Authors | Year | Exposed system | Endpoints | Frequency range | SAR | Exposure duration | Parameters |
---|---|---|---|---|---|---|---|
Hanci H et al. | 2015 | animal, rat/Sprague Dawley, whole body | oxidative stress and histology of spleen and thymus | 900 MHz | 0.025 W/kg | continuous for 1 hour/day between days 13 and 21 of pregnancy | mobile phone, mobile communications |
Odaci E et al. | 2015 | animal, rat/Sprague-Dawley, whole body | histology, apoptosis and oxidative stress in the testes | 900 MHz | 0.025 W/kg | continuous for 1 hour/day for 30 days | mobile phone, mobile communications |
Ragy MM | 2015 | animal, rat/Sprague Dawley albino, whole body | oxidative stress in the brain, liver and kidneys and blood parameters | 900 MHz | - | continuous for 1 hour/day for 60 days | mobile communications |
Turedi S et al. | 2015 | animal, rat/Sprague Dawley, whole body | oxidative stress and histology of the heart | 900 MHz | 0.025 W/kg | continuous for 1 hour/day from day 13 to 21 of pregnancy | mobile phone, mobile communications |
Miyakoshi J et al. | 2005 | intact cell/cell culture, MO54 cells (derived from a human malignant glioma) | activation of stress response genes | 1,950 MHz | 1–10 W/kg | continuous for 1 or 2 h | mobile communications |
Hoyto A et al. | 2008 | intact cell/cell culture, human neuroblastoma cell line (SH-SY5Y) and mouse fibroblasts (L929) | cell proliferation, cell death | 872 MHz | 5 W/kg | continuous for 1 or 24 h | digital mobile phone, GSM, mobile communications |
Moustafa YM et al. | 2001 | human, partial body: cellular phone was placed in the pocket | oxidative stress | 900 MHz | - | continuous for 1, 2 and 4 h | GSM, TDMA, mobile communications |
Roux D et al. | 2006 | plant, tomato (<i>Lycopersicon esculentum</i> Mill.)/VFN8, whole body | stress response of tomato | 900 MHz | - | continuous for 10 min | mobile communications, GSM |
Vian A et al. | 2006 | plant, tomato (<i>Lycopersicon esculentum</i> Mill.)/VFN8, whole body | stress response of tomato | 900 MHz | - | continuous for 10 min | mobile communications, microwaves |
Ozgur E et al. | 2010 | animal, guinea pig, whole body | oxidative stress and nitrosative stress in the liver | 1,800 MHz | 0.38 W/kg | continuous for 10 min./day on 7 days or 20 min./day on 7 days | mobile phone, GSM, mobile communications, PW pulsed wave |
Zeni O et al. | 2007 | intact cell/cell culture, murine L929 cells | formation of reactive oxygen species (oxidative stress) | 900 MHz | 0.3–1 W/kg | continuous for 10 or 30 min | mobile communications, GSM |
Marjanovic AM et al. | 2015 | intact cell/cell culture, V79 (Chinese hamster fibroblast cells) | cell viability, oxidative stress | 1,800 MHz | 1.6 W/kg | continuous for 10, 30 and 60 minutes | mobile phone, GSM, mobile communications |
Meral I et al. | 2007 | animal, guinea pig, whole body | different blood vitamin levels, oxidative stress in the brain | 890–915 MHz | 0.95 W/kg | continuous for 12 h/day (11 h 45 min stand-by mode, 15 min speaking mode) on 30 days | mobile communications, mobile phone, RF field |
Hussein S et al. | 2016 | animal, rat | changes and damage in the rat brain | 1,800 MHz | 0.6 W/kg | continuous for 120 min/day for three months | mobile phone, mobile communications |
Kismali G et al. | 2012 | animal, rabbit/New Zealand White, whole body | blood chemistry, oxidative stress: lipid persoxidation | 1,800 MHz | - | continuous for 15 min/day during 7 days (day 15 to day 22 of gestation) | digital mobile phone, GSM, mobile communications, microwaves, PW pulsed wave |
Tomruk A et al. | 2010 | animal, rabbit/New Zealand White, whole body | oxidative stress induced liver damage (hepato-toxicity: DNA damage, lipid peroxidation and malondialdehyde level) | 1,800 MHz | - | continuous for 15 min/day on 7 days | digital mobile phone, GSM, mobile communications, PW pulsed wave |
Guler G et al. | 2012 | animal, rabbit/New Zealand, whole body | effects on the liver of young rabbits (DNA damage and lipid peroxidation) | 1,800 MHz | 1.8 W/kg | continuous for 15 min/day on 7 days (female) or 14 days (male) | digital mobile phone, GSM, mobile communications, PW pulsed wave |
Güler G et al. | 2010 | animal, rabbit/New Zealand White, whole body | lipid peroxidation and DNA damage in the brain | 1,800 MHz | - | continuous for 15 min/day on 7 days - from day 15 to day 22 of gestation | mobile phone, GSM, mobile communications |
Esmekaya MA et al. | 2016 | animal, mouse/Swiss albino, whole body | oxidative stress in the brain | 900 MHz | 0.301–0.367 W/kg | continuous for 15 minutes and 30 minutes | mobile phone, GSM, mobile communications |
Bodera P et al. | 2015 | animal, rat/Wistar, whole body | lipid peroxidation in brain, blood, liver and kidney | 1,800 MHz | 0.024–0.028 W/kg | continuous for 15 minutes/day for 5 days | mobile phone base station, GSM, TDMA, mobile communications, co-exposure |
Al-Damegh MA | 2012 | animal, rat/Wistar, whole body | histopathological alterations in the testis, oxidative stress in blood and testis | 900–1,900 MHz | 0.9 W/kg | continuous for 15, 30 or 60 min/day during 14 days | digital mobile phone, GSM, mobile communications, co-exposure |
De Iuliis GN et al. | 2009 | intact cell/cell culture, human spermatozoa | sperm motility, sperm vitality, sperm density, DNA damage and production of reactive oxygen species | 1.8 GHz | 0.4–27.5 W/kg | continuous for 16 hr | mobile phone, mobile communications |
Stagg RB et al. | 2001 | animal, rat/Fischer 344, partial body: head | stress response | 1.6 GHz | 0.6–5 W/kg | continuous for 2 h | digital mobile phone, IRIDIUM, mobile communications, microwaves |
Lixia S et al. | 2006 | intact cell/cell culture, SRA01/04-hLEC (human eye lens epithelial cells) | comet assay, stress response/gene expression, cell proliferation | 1.8 GHz | 1–3 W/kg | continuous for 2 h | digital mobile phone, GSM, TDMA, mobile communications |
Sanchez S et al. | 2008 | animal, rat/hairless, partial body: right part of the back | Heat shock protein expression | 900 MHz | 2.4–5.8 W/kg | continuous for 2 h | GSM, mobile communications |
Khalil AM et al. | 2012 | animal, rat/Sprague-Dawley, whole body | DNA damage/oxidative stress (urinary level of 8-hydroxy-2-deoxyguanosine) | 1,800 MHz | - | continuous for 2 h | mobile phone, GSM, mobile communications |
Hong MN et al. | 2012 | intact cell/cell culture, MCF10 A cells (human breast epithelial cells) | oxidative stress | 837 MHz | 2–4 W/kg | continuous for 2 h | mobile phone, CDMA, W-CDMA, mobile communications |
Khirazova EE et al. | 2012 | animal, white rat, whole body | behavior in open field test, antioxidant defense system | 905 MHz | 1.67 W/kg | continuous for 2 h | digital mobile phone, GSM, mobile communications, PW pulsed wave |
Calabro E et al. | 2012 | intact cell/cell culture, SH-SY5Y (human neuroblastoma cell line) | cellular stress response (heat shock protein expression, cell viability and apoptosis) | 1,760 MHz | 0.086 W/kg | continuous for 2 h and 4 h | mobile phone, GSM, mobile communications |
Cao H et al. | 2015 | animal, rat/Sprague-Dawley, whole body | circadian concentration of melatonin, superoxide dismutase and glutathione peroxidase in blood | 1.8 GHz | 0.05653 W/kg | continuous for 2 h/day for 32 days | mobile phone, mobile communications |
Meena R et al. | 2014 | animal, rat/Wistar, whole body | oxidative stress and damage in the testes | 2.45 GHz | 0.14 W/kg | continuous for 2 h/day for 45 days | mobile communications, microwaves, 2.45 GHz, co-exposure |
Cao Y et al. | 2009 | intact cell/cell culture, SHG44 cells (human glioma cells) | oxidative stress, cell proliferation, cell cycle distribution, apoptosis | 900 MHz | - | continuous for 2 h/day on 3 days | mobile phone, mobile communications, co-exposure |
Kesari KK et al. | 2011 | animal, rat/Wistar, whole body | oxidative stress and metabolism in the brain | 900 MHz | 0.9 W/kg | continuous for 2 h/day on 45 days | mobile phone, GSM, FDMA, TDMA, mobile communications, PW pulsed wave |
Dasdag S et al. | 2008 | animal, rat/Wistar albino | - | 900 MHz | - | continuous for 2 h/day, 7 days/week for 10 months | digital mobile phone, GSM, mobile communications |
Tkalec M et al. | 2013 | invertebrate, earthworm (<i>Eisenia fetida</i>), whole body | genotoxicity, oxidative stress | 900 MHz | 0.13–9.33 mW/kg | continuous for 2 hours | mobile phone, mobile communications |
Kang KA et al. | 2014 | intact cell/cell culture, NIH3T3 cells (mouse fibroblasts), U87 (human glioma cells), PC12 (rat pheochromocytoma cells), SH-SY5Y (human neuroblastoma cells) | cell viability, oxidative stress | 837–1,950 MHz | 2 W/kg | continuous for 2 hours | mobile phone, CDMA, W-CDMA, mobile communications, co-exposure |
Kazemi E et al. | 2015 | intact cell/cell culture, human peripheral blood | reactive oxygen species in monocytes and lymphocytes | 900 MHz | - | continuous for 2 hours | mobile phone, GSM, mobile communications, PW pulsed wave |
Lee JS et al. | 2016 | intact cell/cell culture, HT22 (mouse hippocampus neuronal cells) | cytotoxicity | 837–1,950 MHz | 2 W/kg | continuous for 2 hours | mobile phone, CDMA, W-CDMA, mobile communications, also other exposures without EMF, co-exposure |
Kumari K et al. | 2012 | animal, rat/Wistar, whole body | effects on liver: oxidative stress and liver values | 900 MHz | 0.15 W/kg | continuous for 2 hours/day for 35 days | mobile phone, GSM, mobile communications, microwaves, 2.45 GHz |
Kesari KK et al. | 2014 | animal, rat/ Wistar, whole body | DNA damage, protein expression, apoptosis and oxidative stress in brain | 2,115 MHz | 0.26–0.9 W/kg | continuous for 2 hours/day for 60 days | mobile phone, mobile communications |
Kumar S et al. | 2014 | animal, rat/Wistar albino, whole body | effects on testis and sperms | 1,910.5 MHz | 0.0226–1.34 W/kg | continuous for 2 hours/day on 6 days/week for 60 days | mobile phone, mobile communications |
Dasdag S et al. | 2009 | animal, rat/Wistar albino, partial body: head | apoptosis and oxidative stress in the brain | 900 MHz | 0.17–0.58 W/kg | continuous for 2 hr/day, 7 days/week for 10 months | mobile communications, mobile phone, GSM, microwaves |
Hirose H et al. | 2007 | intact cell/cell culture, A172 (human glioblastoma cells) and IMR90 fibroblasts (from fetal lungs) | cellular stress response (Hsp27 (heat-shock protein 27) content and hsp27 phosphorylation) | 2.1425 GHz | 80–800 mW/kg | continuous for 2, 24, or 48 h for A172 cells | mobile phone base station, CDMA, mobile communications, microwaves |
Dawe AS et al. | 2008 | invertebrate, <i>Caenorhabditis elegans</i>/PC72 (transgenic, with reporter gene construct encoding beta-galactosidase under control of <i>hsp16</i> heat shock promotor), whole body | expression of heat shock protein | 1.8 GHz | 1.8 W/kg | continuous for 2.5 h | digital mobile phone, GSM, mobile communications |
Hook GJ et al. | 2004 | intact cell/cell culture, J774.16 (mouse macrophage cells) | oxidative stress | 835.62 MHz | 800 µW/g | continuous for 20 to 22 h | CDMA, mobile communications, CW continuous wave |
Huang TQ et al. | 2008 | intact cell/cell culture, HEI-OC1 cells (immortalized mouse auditory hair cells) | cell cycle, DNA damage, stress response, and gene expression | 1,763 MHz | 20 W/kg | continuous for 24 h and 48 h | mobile communications, mobile phone, CDMA |
Goswami PC et al. | 1999 | intact cell/cell culture, C3H 10T1/2 cells (derived from mouse embryo fibroblasts) | stress response (proto-oncogene expression and DNA-binding activity of transcription factors) | 835.62 MHz | 0.6 W/kg | continuous for 24 h or 4 days | mobile communications, CDMA |
Marzook EM et al. | 2014 | animal, rat/albino | oxidative stress and other parameters in the blood | 900 MHz | - | continuous for 24 h/day for 8 weeks | mobile phone base station, mobile communications, co-exposure |
Wang X et al. | 2015 | intact cell/cell culture, Neuro-2a (mouse neuroblastoma) cells | DNA damage, oxidative stress and cell viability | 900 MHz | 0.5–2 W/kg | continuous for 24 hours | mobile phone, GSM, mobile communications, co-exposure |
Hirose H et al. | 2006 | intact cell/cell culture, A172 (human glioblastoma cells) and IMR90 fibroblasts (from fetal lungs) | apoptosis, cellular stress response | 2.1425 GHz | 80–800 mW/kg | continuous for 24 or 48 h | mobile phone base station, CDMA, mobile communications |
This website uses cookies to provide you the best browsing experience. By continuing to use this website you accept our use of cookies.